When drilling into brick or concrete block, you will need _______ plus your
protective equipment - -Hammer drill and masonry bit
- T/F When selecting personal protective equipment for protection against
air borne particles, a dust mask is not considered a respirator ` - -False
- A ____ bit is required with a hole in the end for the purpose of attaching a
wire - -Bell Hanger
- A __ is used for pulling wires and cables through a conduit - -Fish Tape
- Which of the following is not considered a specialty CCTV tool?
a.) tone generator with probe
b.) compression tool
c.) test monitor
d.) coax stripper - -A
- A hybrid system does which of the following? - --Combines hardwired and
wireless technologies
- uses resistors for supervision
- combines technologies allowing you to keep cost down
ALL
- Which one is not a component of a CPU?
a.) potentiometer
b.) PGM terminal
c.) heat sink
d.) PIR - -D
- T/F primary power should never be unswitched - -False
- T/F The function of the communicator is to transmit a signal to a
predetermined location - -True
- What would you expect in/from an alarm control panel? - -- responds to
user inputs
-responds to signals form initialing devices
-activates notifications devices
-performs off-site notifications
ALL
, - Y/N 24AWG ---> 3.5 MAX CURRENT -----> 88OHMS PER 1000 FT - -yes its
current carrying capacities
- T/F Every control panel does not require a means for the customer to
submit request for arming, disarming, bypassing zones or obtain system
status and history. - -False
- A small subdivision into which large areas are divided to permit selective
access to some while maintaining other zone secure defines what? - -Zone
- A good device or location to program as a zone type 2 is? - -Overhead
door or door needing extended entry delay
- A smoke detector should be programmed as what zone type? - -type 09
- T/F If a device programmed as type 22 is tripped, it will activate the
bell/siren circuit. - -False
- T/F when using a normally closed contract, a protective loop will open
during an alarm event - -False
- T/F A normally open contract will allow potential to move through the
contract when under the influence of a magnetic field - -True
- Windows located more than 18 feet above the ground or other roofs are
considered _____ - -inaccessable
- T/F An intruder entering a premise through a broken window would be
detected if a magnetic contact were installed on the window. - -False
- When installing magnetic contact on a movable window, the _____ must be
placed on the movable portion of the window - -Magnet
- __________ should be installed in front of and within range of the windows
they are designed to protect - -Glass break sensors
- T/F Smoke alarms are more commonly used by the home builders due to
their increased sensitivity - -False
- A smoke ____ is connected to a circuit which is connected to an alarm
pannel. - -Detector
- T/F If a siren is "integral" to the burglar alarm panel, it is not built-in to the
panel - -False
and Answers
When drilling into brick or concrete block, you will need _______ plus your
protective equipment - -Hammer drill and masonry bit
- T/F When selecting personal protective equipment for protection against
air borne particles, a dust mask is not considered a respirator ` - -False
- A ____ bit is required with a hole in the end for the purpose of attaching a
wire - -Bell Hanger
- A __ is used for pulling wires and cables through a conduit - -Fish Tape
- Which of the following is not considered a specialty CCTV tool?
a.) tone generator with probe
b.) compression tool
c.) test monitor
d.) coax stripper - -A
- A hybrid system does which of the following? - --Combines hardwired and
wireless technologies
- uses resistors for supervision
- combines technologies allowing you to keep cost down
ALL
- Which one is not a component of a CPU?
a.) potentiometer
b.) PGM terminal
c.) heat sink
d.) PIR - -D
- T/F primary power should never be unswitched - -False
- T/F The function of the communicator is to transmit a signal to a
predetermined location - -True
- What would you expect in/from an alarm control panel? - -- responds to
user inputs
-responds to signals form initialing devices
-activates notifications devices
-performs off-site notifications
ALL
, - Y/N 24AWG ---> 3.5 MAX CURRENT -----> 88OHMS PER 1000 FT - -yes its
current carrying capacities
- T/F Every control panel does not require a means for the customer to
submit request for arming, disarming, bypassing zones or obtain system
status and history. - -False
- A small subdivision into which large areas are divided to permit selective
access to some while maintaining other zone secure defines what? - -Zone
- A good device or location to program as a zone type 2 is? - -Overhead
door or door needing extended entry delay
- A smoke detector should be programmed as what zone type? - -type 09
- T/F If a device programmed as type 22 is tripped, it will activate the
bell/siren circuit. - -False
- T/F when using a normally closed contract, a protective loop will open
during an alarm event - -False
- T/F A normally open contract will allow potential to move through the
contract when under the influence of a magnetic field - -True
- Windows located more than 18 feet above the ground or other roofs are
considered _____ - -inaccessable
- T/F An intruder entering a premise through a broken window would be
detected if a magnetic contact were installed on the window. - -False
- When installing magnetic contact on a movable window, the _____ must be
placed on the movable portion of the window - -Magnet
- __________ should be installed in front of and within range of the windows
they are designed to protect - -Glass break sensors
- T/F Smoke alarms are more commonly used by the home builders due to
their increased sensitivity - -False
- A smoke ____ is connected to a circuit which is connected to an alarm
pannel. - -Detector
- T/F If a siren is "integral" to the burglar alarm panel, it is not built-in to the
panel - -False