FDNYC G60 Practice Exam 2025 Complete Questions And Verified Answers/ Complete Solutions With Rationales |Get It 100% Accurate!! Already graded A+
FDNYC G60 Practice Exam 2025 Complete Questions And Verified Answers/ Complete Solutions With Rationales |Get It 100% Accurate!! Already graded A+ All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current - AnswerCertificate of Fitness The Certificate of Fitness holder - Answermust regulate the pressure and flow of oxygen and natural gas to each torch. if the torch operator for jewelry manufacture involves - Answerany oxygen with any fuel gas containers, the operator must be a C of F holder. A Certificate of Fitness Holder must keep his or her certificate - Answeron their person or otherwise readily available for inspection by any representative of the fire Department The easiest way to extinguish a fire caused by a leak is to - Answerclose the shutoff valve Permits issued by the FDNY are required to conduct the following hot work: - Answerstoring, using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF. For LPG, 400 SCF is - Answerapproximately 47 lbs the number of LPG containers for the storage, use, handling or transportation, requiring a permit - Answer14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont. 33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont. Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater than 8.7 SCF - Answermust NOT stored, handled, or used indoors in the following occupancies (as defined in the Building code): residential occupancies, factory and industrial occupancies; educational occupancies; institutional occupancies, except as the commissioner may authorize by rule. Site-specific permit - Answermay be a permanent permit or a temporary permit. Permanent permits are valid for 12 months only A city-wide permit is valid - Answerup to 30 days Permits shall be - Answerreadily available on the premise for inspection by Fire Department representatives. Hot work authorization should be issued by the responsible person, and it - Answermust be available for inspection by any representative of the department during the performance of the work, and for 48 hours after the work is complete
Documentinformatie
- Geüpload op
- 23 maart 2025
- Aantal pagina's
- 7
- Geschreven in
- 2024/2025
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden