NATE GAS HEAT STUDY GUIDE TEST. 3/8 to ½ inch of the end of the thermocouple - CORRECT ANSWER Should be enveloped by the pilot flame A control string is defined as two or more switch contacts connected in a circuit, or set of circuits, to control a load. In order to troubleshoot a load controlled by a control string, the technician must first: - CORRECT ANSWER Check for proper voltage applied across the load. A customer complains the unit is "blowing cold air". The technician determines that the problem occurs at the end of the heating sequence. The furnace used an electronic integrated blower control. - CORRECT ANSWER The likely problem with the system is the blower off delay is set too long. A customer has concerns about carbon monoxide (CO) in their hone. Many of their reported symptoms indicate there may indeed be a CO problem but on each trip the technician makes to check their home the technician finds normal CO levels. - CORRECT ANSWER CO detector reader/recorder would be appropriate to use for determining if a problem truly exists. A damaged section of double wall vent pipe is to be replaced with a section produced by a different manufacturer: - CORRECT ANSWER The installer should check the new section for compatible locking joints. A dirty or clogged air filter in an operating gas furnace can cause an: - CORRECT ANSWER Increase temperature rise. A furnace is inoperative because of a failure in the ignition sequence at the flame proving stage. To check the flame proving circuit the technician would: - CORRECT ANSWER Connect a microampmeter set to DC microamps in the sensor circuit and operate the furnace. A gas clothes dryer can interfere with the operation of a nearby natural draft gas furnace with an atmospheric burner by: - CORRECT ANSWER Stealing combustion air preventing complete fuel burning. A gas furnace should reach a steady state - CORRECT ANSWER Before taking a combustion test A gas furnace with a standing pilot uses a flame switch for proving pilot flame. - CORRECT ANSWER Several millivolts are generated by the flame. A line voltage fuse is sized to protect from: - CORRECT ANSWER Excessive voltage A meter reading microfarads is used to: - CORRECT ANSWER Check a run capacitor with a capacitance tester. A packaged unit in a two story installation is to be located at ground level with ductwork running up the outside wall to a chase in the second floor. - CORRECT ANSWER The precautions need to be taken with outside ductwork is it must be insulated and weatherproofed. A standing pilot furnace uses a relay for controlling the supply blower. On a call for heat, the burner lights, the fan control closes, but the blower does not run. A check of voltage at the blower relay coil shows 24V. The load side measures 0V. The technician should replace what: - CORRECT ANSWER Fan relay. A system airflow check determines that supply static is 0.15 in. W.C. and return static is a negative 0.55 in. W.C. these readings tell the technician: - CORRECT ANSWER The difference between supply static and return static is unacceptably low. A system that is oversized for the load: - CORRECT ANSWER Will cause the unit to short cycle. A technician is installing a gas furnace and the customer has decided not to install an air conditioner. Making this decision, the affect it will have on the installation of the supply ductwork is: - CORRECT ANSWER Leave adequate space should be allowed for addition of a coil in the future when feasible. A technician measures the return air temperature of a 100,000 BTU output gas furnace to be 65°F and the supply side air temperature is 135°F: - CORRECT ANSWER The CFM would be 1323.

Content preview

NATE GAS HEAT STUDY GUIDE TEST.

3/8 to ½ inch of the end of the thermocouple - CORRECT ANSWER Should be enveloped by the pilot
flame



A control string is defined as two or more switch contacts connected in a circuit, or set of circuits, to
control a load. In order to troubleshoot a load controlled by a control string, the technician must first: -
CORRECT ANSWER Check for proper voltage applied across the load.



A customer complains the unit is "blowing cold air". The technician determines that the problem occurs
at the end of the heating sequence. The furnace used an electronic integrated blower control. -
CORRECT ANSWER The likely problem with the system is the blower off delay is set too long.



A customer has concerns about carbon monoxide (CO) in their hone. Many of their reported symptoms
indicate there may indeed be a CO problem but on each trip the technician makes to check their home
the technician finds normal CO levels. - CORRECT ANSWER CO detector reader/recorder would be
appropriate to use for determining if a problem truly exists.



A damaged section of double wall vent pipe is to be replaced with a section produced by a different
manufacturer: - CORRECT ANSWER The installer should check the new section for compatible locking
joints.



A dirty or clogged air filter in an operating gas furnace can cause an: - CORRECT ANSWER Increase
temperature rise.



A furnace is inoperative because of a failure in the ignition sequence at the flame proving stage. To
check the flame proving circuit the technician would: - CORRECT ANSWER Connect a microampmeter
set to DC microamps in the sensor circuit and operate the furnace.



A gas clothes dryer can interfere with the operation of a nearby natural draft gas furnace with an
atmospheric burner by: - CORRECT ANSWER Stealing combustion air preventing complete fuel burning.

, A gas furnace should reach a steady state - CORRECT ANSWER Before taking a combustion test



A gas furnace with a standing pilot uses a flame switch for proving pilot flame. - CORRECT ANSWER
Several millivolts are generated by the flame.



A line voltage fuse is sized to protect from: - CORRECT ANSWER Excessive voltage



A meter reading microfarads is used to: - CORRECT ANSWER Check a run capacitor with a capacitance
tester.



A packaged unit in a two story installation is to be located at ground level with ductwork running up the
outside wall to a chase in the second floor. - CORRECT ANSWER The precautions need to be taken with
outside ductwork is it must be insulated and weatherproofed.



A standing pilot furnace uses a relay for controlling the supply blower. On a call for heat, the burner
lights, the fan control closes, but the blower does not run. A check of voltage at the blower relay coil
shows 24V. The load side measures 0V. The technician should replace what: - CORRECT ANSWER Fan
relay.



A system airflow check determines that supply static is 0.15 in. W.C. and return static is a negative 0.55
in. W.C. these readings tell the technician: - CORRECT ANSWER The difference between supply static
and return static is unacceptably low.



A system that is oversized for the load: - CORRECT ANSWER Will cause the unit to short cycle.



A technician is installing a gas furnace and the customer has decided not to install an air conditioner.
Making this decision, the affect it will have on the installation of the supply ductwork is: - CORRECT
ANSWER Leave adequate space should be allowed for addition of a coil in the future when feasible.



A technician measures the return air temperature of a 100,000 BTU output gas furnace to be 65°F and
the supply side air temperature is 135°F: - CORRECT ANSWER The CFM would be 1323.

Document information

Uploaded on
March 16, 2025
Number of pages
13
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ROSEGRADES
3.4
(35)
Sold
236
Followers
87
Items
12121
Last sold
1 month ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions