BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM

Content preview

BACKFLOW PREVENTION ASSEMBLY TESTER
PRACTICE EXAM
In responding to a backflow incident the water purveyor should

(A) Call the mayor
(B) Implement the emergency response plan
(C) Install a vacuum breaker
(D) Develop a good excuse - Answers :Implement the emergency response plan

A mixture of air and gas is considered hazardous when the mixture exceeds what
percentage of gthe lower explosive limit

(A) 0%
(B) 3%
(C) 7%
(D) 10% - Answers :10%

To exert a pressure of 1.0 psi at base of a water column the column would have to be

(A) 4.34 high
(B) 14.7 high
(C) 27.75 high
(D) 33.89 high - Answers :27.75 high


When field testing the #1 Check of a RP the differential pressurw shouid be

(A) Greter than or equal to 5.0 psid
(B) 3.0 psid greater than the relief valve opening point
(C) 1.0 psid in the directiom of flow
(D) Less than 5.0 psid - Answers :Greter than or equal to 5.0 psid

When testing a SVB what is the firsrt test being performed

(A) The air inlet opening point
(B) The static pressure across the check valve
(C) To verify the #2shut off hold tight
(D) To check if the SVB hold water - Answers :The static pressure across the check
valve

When testing a PVB the air inlet opens upon closing the #1 shut off valve What is the
most probable cause

(A) Leaking #2 shut off valve

,(B) Leaking #1 shut off valve
(C) Fouied air inlert
(D) Fouied check valve - Answers :Leaking #2 shut off valve

A 2" AVB when used on irrigation systemsterm-15 shall be instilled

(A) 6" above all downstream piping
(B) 18" above all downstream piping
(C) 24" above all downstream piping
(D) 27 3/4" above all downstream piping - Answers :6" above all downstream piping

What causes the relief valief valve to close on a RPZ?

(A) Reilef valve spring pressure
(B) Supply side water pressure
(C) Pressure differential between Check #1 and Check #2
(D) All the above - Answers :Supply side water pressure

When testing a RP instialled in vauil the relief valve opening point falls to zero What is
most probabie cause

(A) The relief valve is stuck shut
(B) #1 check is fouled
(C) the #2 shut off leaks by
(D) Installed improperly - Answers :Installed improperly

A DC must be tested

(A) Upon installation
(B) Every 6 month
(C) Annually on a health hazard
(D) none of the above - Answers :Upon installation

An absolute perssure of 25 psiaa (at sea level) is equal to approximately

(A) 5 psi
(B) 10 psi
(C) 20 psi
(D) 25 psi - Answers :10 psi

Dueing a field test the air inlet on PVB must open at

(A) Above 2.0 psid
(B) Below 1.0 psid
(C) Above 1.0 psid
(D) Below 2.0 psid - Answers :Above 1.0 psid

, A differential pressuer gauge is used to field test

(A) PVB's
(B) Dual Checks
(C) AVB's
(D) All the above - Answers :PVB's

Backflow in a water supply can be caused by

(A) Backpressure only
(B) A Barometric Loop
(C) Backsiphonage only
(D) Backpressure and Backsiphonage - Answers :Backpressure and Backsiphonage

A BPAT tester is required to report test information on the proper forms to the

(A) Administrative authority
(B) Manufacturer's Rep
(C) EPA
(D) None of the above - Answers :Administrative authority

The relief valve opens when closing #2 shut off valve on a RP What is the most
probable cause

(A) #1 Shut off valve is open
(B) #2 Shut off valve is open
(C) #1 check is fouled open
(D) Shut off is leaking - Answers :#1 check is fouled open

When field testing the DC the #1 check static differential pressure is found to be 0.0
psid What is the most probable cause

(A) Fouied #2 Check
(B) Leaking #2 shut off
(C) Fouled #1 check
(D) Leaking #1 shut off - Answers :Fouled #1 check

The critical level for checking the air inlet of the PVB is

(A) At the air inlet
(B) At #1 shut off
(C) At #1 test cock
(D) At #2 shut off - Answers :At the air inlet

The physical operation of a Hose Bibb Vacuum Breaker is classified as a type of

Document information

Uploaded on
March 9, 2025
Number of pages
17
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Greaterheights
4.0
(224)
Sold
1174
Followers
882
Items
20553
Last sold
4 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions