what type of refrigerant is used in VERY high-pressure appliances? - ANSWER -R-503 what type of refrigerant is used in MEDIUM pressure appliances? - ANSWER -R-500 what type of refrigerant is used in HIGH pressure appliances? - ANSWER -R-410A and R-22 what device is located at the END of the liquid line? - ANSWER -The expansion device. what type of refrigerants are the LEAST harmful to the ozone layer? - ANSWER -HFC refrigerants. How much money does the EPA offer to individuals who report information about others who vent refrigerants into the atmosphere? - ANSWER -$10,000. which class of refrigerants does R-22 fall into? - ANSWER -The HCFC class. (hydrochloroflurocarbons) which gas should be used when checking for leaks in various systems? - ANSWER -Nitrogen. which term describes the process of changing a refrigerant from a liquid to a gas using HEAT? - ANSWER -Latent heat. refrigerants in the SUCTION line are in what phase and state? - ANSWER -Cold vapor. how many miles above the Earth's surface does the ozone layer in the stratosphere extend? - ANSWER -31 miles. what year was the Montreal Protocol put in place? - ANSWER -1989. refrigerant recovery equipment should be checked for (blank) on a daily basis? - ANSWER -Refrigerant leaks and oil levels. should recovery machines be used on equipment that contains hydrogen? - ANSWER -NO. which purity test is used to determine the type of refrigerant? - ANSWER -ARI 700. what type of unit only requires ONE service connection? - ANSWER -self-contained recovery units. air will cause (blank) discharge pressures in a refrigeration system. - ANSWER -Higher. a strong odor is around during the recovery process. what is most likely the cause of this? - ANSWER -A compressor burnout. what is the best way (position) to transport refrigeration cylinders? - ANSWER -Upright. you can only accurately read refrigerant pressure with a stable (blank)? - ANSWER -Temperature. an explosion can occur if (blank) is vented in an enclosed environment? - ANSWER -Hydrogen. can refrigerants be mixed in a recovery tank? - ANSWER -NO. what is the state of refrigerant leaving the liquid receiver? - ANSWER -High pressure liquid.

Aperçu du contenu

UPDATED EPA 608 QUIZLET
(2023)questions and correct detailed
Answers

the state of the refrigerant entering the metering device is? - ANSWER -A subcooled
high pressure liquid.

what type of refrigerant is used in VERY high-pressure appliances? - ANSWER -R-503

what type of refrigerant is used in MEDIUM pressure appliances? - ANSWER -R-500

what type of refrigerant is used in HIGH pressure appliances? - ANSWER -R-410A and
R-22

what device is located at the END of the liquid line? - ANSWER -The expansion device.

what type of refrigerants are the LEAST harmful to the ozone layer? - ANSWER -HFC
refrigerants.

How much money does the EPA offer to individuals who report information about others
who vent refrigerants into the atmosphere? - ANSWER -$10,000.

which class of refrigerants does R-22 fall into? - ANSWER -The HCFC class.
(hydrochloroflurocarbons)

which gas should be used when checking for leaks in various systems? - ANSWER -
Nitrogen.

which term describes the process of changing a refrigerant from a liquid to a gas using
HEAT? - ANSWER -Latent heat.

refrigerants in the SUCTION line are in what phase and state? - ANSWER -Cold vapor.

how many miles above the Earth's surface does the ozone layer in the stratosphere
extend? - ANSWER -31 miles.

what year was the Montreal Protocol put in place? - ANSWER -1989.

refrigerant recovery equipment should be checked for (blank) on a daily basis? -
ANSWER -Refrigerant leaks and oil levels.

, should recovery machines be used on equipment that contains hydrogen? - ANSWER -
NO.

which purity test is used to determine the type of refrigerant? - ANSWER -ARI 700.

what type of unit only requires ONE service connection? - ANSWER -self-contained
recovery units.

air will cause (blank) discharge pressures in a refrigeration system. - ANSWER -Higher.

a strong odor is around during the recovery process. what is most likely the cause of
this? - ANSWER -A compressor burnout.

what is the best way (position) to transport refrigeration cylinders? - ANSWER -Upright.

you can only accurately read refrigerant pressure with a stable (blank)? - ANSWER -
Temperature.

an explosion can occur if (blank) is vented in an enclosed environment? - ANSWER -
Hydrogen.

can refrigerants be mixed in a recovery tank? - ANSWER -NO.

what is the state of refrigerant leaving the liquid receiver? - ANSWER -High pressure
liquid.

what is the minimum microns a vacuum pump must pull when evacuating a system? -
ANSWER -500 microns.

what is usually contained in refrigerants made before 1950? - ANSWER -SO2. (sulfur
dioxide)

what prevents transient slugs of liquid from getting into the compressor? - ANSWER -
Accumulator.

what is the filter drier responsible for removing? - ANSWER -Moisture and Particulates.

can the compressor compress liquid? - ANSWER -NO.

what is the best leak-checking procedure for a pressure decay test? - ANSWER -
Nitrogen.

when the annual leak rate exceeds (blank), all comfort cooling systems with more than
50lb of refrigerant must be repaired. - ANSWER -15%

Infos sur le Document

Publié le
7 mars 2025
Nombre de pages
11
Écrit en
2024/2025
Type
Examen
Contient
Questions et réponses
$11.09

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Vendu
9
Abonnés
2
Éléments
446
Dernière vente
6 mois de cela



Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Vous travaillez sur vos références ?

Créez des citations précises en APA, MLA et Harvard avec notre générateur de sources gratuit.

Vous travaillez sur vos références ?

Foire aux questions