Two resistors are connected in parallel. Resister one measures 300 ohms and
resistor two measures 300 ohms. What is their equivalent resistance? - CORRECT
ANSWER-150 ohms



Fire warning equipment to be installed in residential occupancies shall produce
the audible emergency evacuation signal described in... - CORRECT ANSWER-
ANSI S3.41



The minimum number of restorable fixed temperature spot type heat detectors
that must be tested during each annual test is... - CORRECT ANSWER-Two
detectors or more on each initiating devices circuit



What is the color code requirement for a spot type heat detector rated at 200°F?
- CORRECT ANSWER-White

,Unless otherwise recommended by the manufacturer's published instructions,
single and multiple station smoke alarms installed in one and two family dwellings
shall be replaced every... - CORRECT ANSWER-10 years from the date of
manufacture



When testing a water level supervisory switch serving a pressure tank, a signal
shall indicate if the water level has changed from the required level by... -
CORRECT ANSWER-Rising or falling 3 inches



Fire alarm cables are permitted to be strapped to conduit to support the cable. -
CORRECT ANSWER-False

Fire Alarm Code? - CORRECT ANSWER-NFPA 72



National Electric Code? - CORRECT ANSWER-NFPA 70



AHJ? - CORRECT ANSWER-Authority Having Jurisdiction



Disconnecting means for fire alarm power shall be what color? - CORRECT
ANSWER-Red



If a combination audible visible appliance is installed, the location of the installed
appliance shall be determined by the requirements of... - CORRECT ANSWER-
The visible appliance

,Where non-powered limited wiring is installed exposed, it must be mechanically
protected within how many feet of the finished floor? - CORRECT ANSWER-7
feet



According to NFPA 72 visible notification appliances for non-sleeping areas must
be mounted between — and — inches above the finished floor? - CORRECT
ANSWER-80 & 96



If system impairment occurs, the owner must be notified — and within —? -
CORRECT ANSWER-In writing & 24 hours



Conductors returning to the fire alarm control panel from the last field device on
the circuit might indicate what type of circuit? - CORRECT ANSWER-Class A



Secondary power supplies for an EVAC fire alarm system shall be capable of
operating for a minimum of — of standby followed by — of alarm. - CORRECT
ANSWER-24 hours and 15 minutes



The secondary power supply for protected premises shall automatically provide
power within how many seconds when the primary power fails? - CORRECT
ANSWER-10 seconds



When the temperature exceeds how many degrees Fahrenheit should spot type
smoke detectors not be installed? - CORRECT ANSWER-Above 100°F

, Who is responsible for maintaining personal protective equipment? - CORRECT
ANSWER-The employee



What does GFCI stand for? - CORRECT ANSWER-Ground fault circuit interrupter



After initial installation, a fixed temperature non-restorable spot type heat
detector shall be tested after how many years? - CORRECT ANSWER-15



Heat detectors should be selected to operate at least how many degrees
Fahrenheit above the maximum expected ambient temperature at the ceiling of
the protected space? - CORRECT ANSWER-20°F



According to NFPA 72, testing records of the fire alarm system shall be kept until
the next test and... - CORRECT ANSWER-Every one year after



Who is responsible for storing and maintaining test records for the fire alarm
system? - CORRECT ANSWER-Owner of the system



Household fire alarm system smoke detectors shall be tested by a technician how
regularly? - CORRECT ANSWER-Annually



Inspection, testing, or maintenance of the fire alarm system shall be permitted to
be done by the building owner or another organization other than the building
owner if... - CORRECT ANSWER-Work is conducted under a written contract

Document information

Uploaded on
March 4, 2025
Number of pages
51
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$27.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
trustednurse
4.9
(2503)
Sold
960
Followers
412
Items
9952
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions