In responding to a backflow incident the water purveyor should

(A) Call the mayor
(B) Implement the emergency response plan
(C) Install a vacuum breaker
(D) Develop a good excuse - (answers)Implement the emergency response plan

A mixture of air and gas is considered hazardous when the mixture exceeds what
percentage of gthe lower explosive limit

(A) 0%
(B) 3%
(C) 7%
(D) 10% - (answers)10%

To exert a pressure of 1.0 psi at base of a water column the column would have to
be

(A) 4.34 high
(B) 14.7 high
(C) 27.75 high
(D) 33.89 high - (answers)27.75 high

A DC must be tested

(A) Upon installation
(B) Every 6 month
(C) Annually on a health hazard
(D) none of the above - (answers)Upon installation

An absolute perssure of 25 psiaa (at sea level) is equal to approximately

,2|Page


(A) 5 psi
(B) 10 psi
(C) 20 psi
(D) 25 psi - (answers)10 psi

Dueing a field test the air inlet on PVB must open at

(A) Above 2.0 psid
(B) Below 1.0 psid
(C) Above 1.0 psid
(D) Below 2.0 psid - (answers)Above 1.0 psid

A differential pressuer gauge is used to field test

(A) PVB's
(B) Dual Checks
(C) AVB's
(D) All the above - (answers)PVB's

Backflow in a water supply can be caused by

(A) Backpressure only
(B) A Barometric Loop
(C) Backsiphonage only
(D) Backpressure and Backsiphonage - (answers)Backpressure and Backsiphonage

A BPAT tester is required to report test information on the proper forms to the

(A) Administrative authority
(B) Manufacturer's Rep
(C) EPA
(D) None of the above - (answers)Administrative authority

The relief valve opens when closing #2 shut off valve on a RP What is the most
probable cause

(A) #1 Shut off valve is open

, 3|Page


(B) #2 Shut off valve is open
(C) #1 check is fouled open
(D) Shut off is leaking - (answers)#1 check is fouled open

When field testing the #1 Check of a RP the differential pressurw shouid be

(A) Greter than or equal to 5.0 psid
(B) 3.0 psid greater than the relief valve opening point
(C) 1.0 psid in the directiom of flow
(D) Less than 5.0 psid - (answers)Greter than or equal to 5.0 psid

When testing a SVB what is the firsrt test being performed

(A) The air inlet opening point
(B) The static pressure across the check valve
(C) To verify the #2shut off hold tight
(D) To check if the SVB hold water - (answers)The static pressure across the check
valve

When testing a PVB the air inlet opens upon closing the #1 shut off valve What is
the most probable cause

(A) Leaking #2 shut off valve
(B) Leaking #1 shut off valve
(C) Fouied air inlert
(D) Fouied check valve - (answers)Leaking #2 shut off valve

A 2" AVB when used on irrigation systemsterm-15 shall be instilled

(A) 6" above all downstream piping
(B) 18" above all downstream piping
(C) 24" above all downstream piping
(D) 27 3/4" above all downstream piping - (answers)6" above all downstream
piping

What causes the relief valief valve to close on a RPZ?

Document information

Uploaded on
March 4, 2025
Number of pages
21
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
Free
Download

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
504
Followers
2
Items
3027
Last sold
20 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions