Hers Rater Questions And Answers With
Verified Solutions Already Passed!!!
What do HERS Providers provide?
ANSWER✔✔ They provide software, oversight, marketing assistance, and quality
assurance for the Rater.
What role does a HERS Trainer play?
ANSWER✔✔ The Trainer trains Raters on how to perform HERS ratings.
What are some of the responsibilities of a HERS Rater?
ANSWER✔✔ The Rater's responsibilities include inspecting and testing the
minimum rated features of the home, entering the data into a RESNET accredited
software tool, and providing the client with reports generated by the software.
Why was RESNET created and by whom?
ANSWER✔✔ RESNET was created to use a scoring system that could compare
the energy use of different houses with each other on a level playing field. It was
created to oversee the HERS industry, provide standards for accreditation of
Raters, Providers, and Trainers, ethics and protocols for inspection, testing, and
software analysis. It was created by the National Association of State Energy
Officers (NASEO) and Energy Rated Homes of America.
What are the minimum rated features of a home?
ANSWER✔✔ The minimum rated features of a home include but are not limited
to the foundation, walls, roof-ceiling, rim joist, doors, windows, skylights, air
infiltration, heating and cooling equipment, heating and cooling distribution
system, duct leakage, domestic water heating, passive solar design, and solar water
heating.
, Can any energy analysis software be used to produce a HERS rating?
ANSWER✔✔ No -- The software must be a RESNET accredited software tool.
Is a Home Energy Rater required to verify compliance with the local energy
code?
ANSWER✔✔ No - The Rater is not required to determine compliance with
regulatory requirements such as construction codes.
If a Rater enters an existing home to perform inspections and testing and the
owner's 9-foot Burmese python is loose, does the Rater have to complete the
inspection and testing?
ANSWER✔✔ No - The Rater is not required to enter any area or perform any
procedure that is likely to be dangerous to the Rater.
Is a Rater required to perform Manual J load calculations?
ANSWER✔✔ No - The Rater is not required to offer or perform HVAC system
design or sizing consultation.
What is a British thermal unit?
ANSWER✔✔ A British thermal unit (Btu) is the amount of heat required to raise
the temperature of one pound of water one degree Fahrenheit at sea level when the
water is 39.2°F.
A homeowner has paid for 17 CCF of natural gas on their monthly bill. How
many Btu's did they use?
ANSWER✔✔ 1 CCF = 102,000 Btu's
17 CCF = 17 x 102,000 = 1,734,000 Btu
Verified Solutions Already Passed!!!
What do HERS Providers provide?
ANSWER✔✔ They provide software, oversight, marketing assistance, and quality
assurance for the Rater.
What role does a HERS Trainer play?
ANSWER✔✔ The Trainer trains Raters on how to perform HERS ratings.
What are some of the responsibilities of a HERS Rater?
ANSWER✔✔ The Rater's responsibilities include inspecting and testing the
minimum rated features of the home, entering the data into a RESNET accredited
software tool, and providing the client with reports generated by the software.
Why was RESNET created and by whom?
ANSWER✔✔ RESNET was created to use a scoring system that could compare
the energy use of different houses with each other on a level playing field. It was
created to oversee the HERS industry, provide standards for accreditation of
Raters, Providers, and Trainers, ethics and protocols for inspection, testing, and
software analysis. It was created by the National Association of State Energy
Officers (NASEO) and Energy Rated Homes of America.
What are the minimum rated features of a home?
ANSWER✔✔ The minimum rated features of a home include but are not limited
to the foundation, walls, roof-ceiling, rim joist, doors, windows, skylights, air
infiltration, heating and cooling equipment, heating and cooling distribution
system, duct leakage, domestic water heating, passive solar design, and solar water
heating.
, Can any energy analysis software be used to produce a HERS rating?
ANSWER✔✔ No -- The software must be a RESNET accredited software tool.
Is a Home Energy Rater required to verify compliance with the local energy
code?
ANSWER✔✔ No - The Rater is not required to determine compliance with
regulatory requirements such as construction codes.
If a Rater enters an existing home to perform inspections and testing and the
owner's 9-foot Burmese python is loose, does the Rater have to complete the
inspection and testing?
ANSWER✔✔ No - The Rater is not required to enter any area or perform any
procedure that is likely to be dangerous to the Rater.
Is a Rater required to perform Manual J load calculations?
ANSWER✔✔ No - The Rater is not required to offer or perform HVAC system
design or sizing consultation.
What is a British thermal unit?
ANSWER✔✔ A British thermal unit (Btu) is the amount of heat required to raise
the temperature of one pound of water one degree Fahrenheit at sea level when the
water is 39.2°F.
A homeowner has paid for 17 CCF of natural gas on their monthly bill. How
many Btu's did they use?
ANSWER✔✔ 1 CCF = 102,000 Btu's
17 CCF = 17 x 102,000 = 1,734,000 Btu