ICC Vapor Recovery 2 Exam Questions And
Answers
After backfilling the vapor return and vent lines, the maximum
pressure drop through the system shall not exceed ________at 60
cubic feet per hour as determined by TP-201.4, Dynamic
Backpressure.
a. 0.75 inches WC
b. 0.5 inches WC
c. 0.32 inches WC
d. 0.55 inches WC -
correct answer ✅c. 0.5 inches WC
CARB's most recent vapor recovery regulations are known as:
a. EVR (enhanced vapor recovery)
b. CVR (California vapor recovery)
c. PVR (protective vapor recovery)
d. ORVR (onboard refueling vapor recovery) -
correct answer ✅a. EVR (enhanced vapor recovery)
A valve installed in a motor-vehicle fueling hose designed to
separate with little or no product
,ICC Vapor Recovery 2 Exam Questions And
Answers
a. breakaway
b. hose clamp
c. sheer valve
d. flow limiter -
correct answer ✅a. breakaway
A Gilbarco Vapor VAC/OPW Vapor Saver system is consdered to
have a vapor recovery equipment defect (VRED) if the vapor escape
guard on an OPW 12 VW nozzle is missing or damaged on at least
____ % of the circumference of the device.
a. 25
b. 50
c. 75
d. 100 -
correct answer ✅c. 75
The two point Phase I vapor recovery system requires that a
separate vapor recovery riser pipe be installed in the tank and be
equipped with a:
, ICC Vapor Recovery 2 Exam Questions And
Answers
a. drop tube
b. locking block valve
c. pressure/vacuum vent
d. vapor recovery adaptor -
correct answer ✅d. vapor recovery adaptor....
When removing liquid from a sump or spill bucket and the liquid
contains fuel, it must be:
a. managed as hazardous waste
b. pumped into a bucket to evaporate
c. scooped or balled onto the concrete pad
d. put it in a sealed container and put into a dump -
correct answer ✅a. managed as hazardous waste
One of the approved methods of overfill prevention is to have an
overfill device that will automatically shut off the fill to the tank
when the tank is at a maximum of ____ % full.
Answers
After backfilling the vapor return and vent lines, the maximum
pressure drop through the system shall not exceed ________at 60
cubic feet per hour as determined by TP-201.4, Dynamic
Backpressure.
a. 0.75 inches WC
b. 0.5 inches WC
c. 0.32 inches WC
d. 0.55 inches WC -
correct answer ✅c. 0.5 inches WC
CARB's most recent vapor recovery regulations are known as:
a. EVR (enhanced vapor recovery)
b. CVR (California vapor recovery)
c. PVR (protective vapor recovery)
d. ORVR (onboard refueling vapor recovery) -
correct answer ✅a. EVR (enhanced vapor recovery)
A valve installed in a motor-vehicle fueling hose designed to
separate with little or no product
,ICC Vapor Recovery 2 Exam Questions And
Answers
a. breakaway
b. hose clamp
c. sheer valve
d. flow limiter -
correct answer ✅a. breakaway
A Gilbarco Vapor VAC/OPW Vapor Saver system is consdered to
have a vapor recovery equipment defect (VRED) if the vapor escape
guard on an OPW 12 VW nozzle is missing or damaged on at least
____ % of the circumference of the device.
a. 25
b. 50
c. 75
d. 100 -
correct answer ✅c. 75
The two point Phase I vapor recovery system requires that a
separate vapor recovery riser pipe be installed in the tank and be
equipped with a:
, ICC Vapor Recovery 2 Exam Questions And
Answers
a. drop tube
b. locking block valve
c. pressure/vacuum vent
d. vapor recovery adaptor -
correct answer ✅d. vapor recovery adaptor....
When removing liquid from a sump or spill bucket and the liquid
contains fuel, it must be:
a. managed as hazardous waste
b. pumped into a bucket to evaporate
c. scooped or balled onto the concrete pad
d. put it in a sealed container and put into a dump -
correct answer ✅a. managed as hazardous waste
One of the approved methods of overfill prevention is to have an
overfill device that will automatically shut off the fill to the tank
when the tank is at a maximum of ____ % full.