ICC Study Cards Exam Questions And
Answers
Which is not a valid type of stage II vapor recovery? -
correct answer ✅Ballast
The Annual Monitor Certification must be performed by -
correct answer ✅A person possessing the appropriate contractor
license AND an individual trained and certified by the manufacturer
of the monitoring equipment
When performing secondary containment testing, what gets
tested? -
correct answer ✅All
According to the Health and Safety Code; tanks installed after July
1, 2003 require a on-time test at installation to determine that the
tank is product tight. Acceptable test methods are: -
correct answer ✅All
A _____________ is an electrical connection between two or more
conductive objects such that they are at the same electrical
potential. -
correct answer ✅Bond
, ICC Study Cards Exam Questions And
Answers
If dispatched in response to a statistical inventory reconciliation
invalid result call, what should be the last thing performed? -
correct answer ✅A tank integrity test
Automatic line leak detector must be replaced if they fail a ____
GPH at _____ PSI test. -
correct answer ✅3, 10
Which is the most hazardous of the petroleum products? -
correct answer ✅Gasoline
An automatic tank gauge can fulfill the leak detector requirement in
California for what situation? -
correct answer ✅Single Wall Tanks
When monitoring a confined space which level of combustible gas
should you monitor for? -
correct answer ✅LEL
The following is true of impressed current cathodic systems: -
correct answer ✅None of the above.
Answers
Which is not a valid type of stage II vapor recovery? -
correct answer ✅Ballast
The Annual Monitor Certification must be performed by -
correct answer ✅A person possessing the appropriate contractor
license AND an individual trained and certified by the manufacturer
of the monitoring equipment
When performing secondary containment testing, what gets
tested? -
correct answer ✅All
According to the Health and Safety Code; tanks installed after July
1, 2003 require a on-time test at installation to determine that the
tank is product tight. Acceptable test methods are: -
correct answer ✅All
A _____________ is an electrical connection between two or more
conductive objects such that they are at the same electrical
potential. -
correct answer ✅Bond
, ICC Study Cards Exam Questions And
Answers
If dispatched in response to a statistical inventory reconciliation
invalid result call, what should be the last thing performed? -
correct answer ✅A tank integrity test
Automatic line leak detector must be replaced if they fail a ____
GPH at _____ PSI test. -
correct answer ✅3, 10
Which is the most hazardous of the petroleum products? -
correct answer ✅Gasoline
An automatic tank gauge can fulfill the leak detector requirement in
California for what situation? -
correct answer ✅Single Wall Tanks
When monitoring a confined space which level of combustible gas
should you monitor for? -
correct answer ✅LEL
The following is true of impressed current cathodic systems: -
correct answer ✅None of the above.