CIP Level 2 Standards Exam Questions and
Answers
SP0 169 - - -
correct answer ✅Control of External Corrosion on Underground or
Submerged Metallic Piping Systems
ANSI / NCSL Z540-6 - - -
correct answer ✅National Calibration Standard
ISO 9000 - - -
correct answer ✅For checks and certification, contact the gauge's
manufacturer or supplier
NACE No. 1 / SSPC-SP 5 - - -
correct answer ✅White Metal Blast Cleaning; Free of all visible oil,
grease , dust, dirt, mill scale, rust, coating, oxides, corrosion
products, and other foreign matter.
NACE No. 2 / SSPC-SP 10 - - -
correct answer ✅Near-White Metal Blast Cleaning; Random
staining shall be limited to no more than 5% of each unit area; Free
of all visible oil, grease , dust, dirt, mill scale, rust, coating, oxides,
corrosion products, and other foreign matter.
, CIP Level 2 Standards Exam Questions and
Answers
NACE No. 3 / SSPC-SP 6 - - -
correct answer ✅Commercial Blast Cleaning; Random staining
shall be limited to no more than 33% of each unit area; Free of all
visible oil, grease , dust, dirt, mill scale, rust, coating, oxides,
corrosion products, and other foreign matter.
NACE No. 4 / SSPC-SP 7 - - -
correct answer ✅Brush-Off Blast Cleaning; Tightly adherent mill
scale, rust, and coating may remain.
NACE No. 8 / SSPC-SP 14 - - -
correct answer ✅Industrial Blast Cleaning; Traces of tightly
adherent mill scale, rust, and coating residues are permitted to
remain on 10 percent of each unit area.
ISO 8501-1, Sa 3 - - -
correct answer ✅Blast-Cleaning to Visually Clean Steel
ISO 8501-1, Sa 2 1/2 - - -
correct answer ✅Very Thorough Blast-Cleaning
Answers
SP0 169 - - -
correct answer ✅Control of External Corrosion on Underground or
Submerged Metallic Piping Systems
ANSI / NCSL Z540-6 - - -
correct answer ✅National Calibration Standard
ISO 9000 - - -
correct answer ✅For checks and certification, contact the gauge's
manufacturer or supplier
NACE No. 1 / SSPC-SP 5 - - -
correct answer ✅White Metal Blast Cleaning; Free of all visible oil,
grease , dust, dirt, mill scale, rust, coating, oxides, corrosion
products, and other foreign matter.
NACE No. 2 / SSPC-SP 10 - - -
correct answer ✅Near-White Metal Blast Cleaning; Random
staining shall be limited to no more than 5% of each unit area; Free
of all visible oil, grease , dust, dirt, mill scale, rust, coating, oxides,
corrosion products, and other foreign matter.
, CIP Level 2 Standards Exam Questions and
Answers
NACE No. 3 / SSPC-SP 6 - - -
correct answer ✅Commercial Blast Cleaning; Random staining
shall be limited to no more than 33% of each unit area; Free of all
visible oil, grease , dust, dirt, mill scale, rust, coating, oxides,
corrosion products, and other foreign matter.
NACE No. 4 / SSPC-SP 7 - - -
correct answer ✅Brush-Off Blast Cleaning; Tightly adherent mill
scale, rust, and coating may remain.
NACE No. 8 / SSPC-SP 14 - - -
correct answer ✅Industrial Blast Cleaning; Traces of tightly
adherent mill scale, rust, and coating residues are permitted to
remain on 10 percent of each unit area.
ISO 8501-1, Sa 3 - - -
correct answer ✅Blast-Cleaning to Visually Clean Steel
ISO 8501-1, Sa 2 1/2 - - -
correct answer ✅Very Thorough Blast-Cleaning