A 75-kVA, 3-phase transformer, 480-volt primary is supplied by 3 AWG THW copper feeder conductors and protected by a 100-ampere (inverse time) circuit breaker.The feeder conductors supplying the transformer are sized according to the Code. (All conductors and terminations are marked 75°C.)True The 100-ampere circuit breaker in the previous question protects the transformer according to Code.Tru

Content preview

Transformers Level II Lesson 4: Understanding
Transformer Overcurrent Protection (22 Questions;
Third Year) questions and answers
A 75-kVA, 3-phase transformer, 480-volt primary is supplied by 3 AWG THW copper feeder
conductors and protected by a 100-ampere (inverse time) circuit breaker.The feeder conductors
supplying the transformer are sized according to the Code. (All conductors and terminations are
marked 75°C.)✔✔True




The 100-ampere circuit breaker in the previous question protects the transformer according to
Code.✔✔True




- Determine if the 350-ampere circuit breaker protects the transformer




- Determine if the feeder is sized properly for the transformer load✔✔- Yes




- Yes




For an installation with a 125-kVA, 3-phase transformer, a 240-volt primary, and THWN copper
conductors, determine the maximum size OCPD permitted that will protect the conductors and
the primary of the transformer where the protection method is primary-only protection. There is
more than one option here, so be sure to select only the maximum circuit breaker and wire
combination that is NEC compliant.✔✔400A circuit breaker with 500 kcmil THWN copper

, For an installation with a 25-kVA, 3-phase transformer, a 208-volt primary, and THWN copper
conductors, determine the maximum size OCPD permitted that will protect the 4 AWG THWN
copper conductors and the primary of the transformer where the method is primary-only
protection. This solution works without the need for additional options. Note: All conductor
terminations are rated 75°C.✔✔90 A




For an installation using primary and secondary protection for a 35-kVA, 3-phase transformer
and a 240-volt, 3-phase, 3-wire secondary, calculate the maximum rating of the secondary OCPD
using Table 450.3(B), Note 1.✔✔110 A




Using non-time-delay fuses, calculate the maximum standard rating for the secondary
overcurrent protective device of a transformer with a secondary current of five amperes. The
transformer is rated 480/120 volts, single-phase, and primary and secondary protection is
provided.✔✔6 A




For an installation with a 45-kVA, 3-phase transformer, a 460-volt primary, a 220-volt secondary,
and secondary protection where the transformer secondary overcurrent protection does not
exceed 125% of the secondary current, determine the maximum standard rating of the primary
feeder OCPD, where primary and secondary overcurrent protection are provided for the
transformer.✔✔125 A




For an installation with a 5-kVA, single-phase transformer, a 480-volt primary, a 220-volt
secondary, 25-ampere fuses as secondary protection, and a 30-ampere circuit breaker as primary
winding and feeder protection, the 30-ampere circuit breaker provides the Code-required primary
protection at not more than 250% of the rated primary current.✔✔False

Document information

Uploaded on
February 23, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
212
Last sold
-



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions