GAS CFESA PRACTICE TEST ACTUAL 2025 WITH 100 QUESTIONS AND CORRECT ANSWERS | ALREADY GRADED A+ | GUARANTEED PASS | GAS CFESA FINAL LATEST VERSION 2025 [BRAND NEW!!] Measuring static gas pressure will tell you if you have sufficient gas ______ to meet the required nameplate data. A) No load pressure B) Volume C) Pressure and volume D) Gas flow - ANSWER- A A running pressure measurement will tell you if you have sufficient gas _______ to allow the gas fired equipment to operate properly. A) No load pressure B) Volume C) Pressure and volume D) Gas flow - ANSWER- C The minimum incoming gas pressure, before a gas pressure regulator, must be _______. A) The operating pressure rating on the equipment data plate B) Determines by the utility company C) At least 1 in w.c. above the required operating pressure D) At least 5 in w.c. above the required operating pressure - ANSWER- C To properly take a gas pressure reading on a piece of gas fired equipment all of the burners ___? A) Should be turned off B) Must be clean C) Must be set to a bypass flame height D) Must be turned full on - ANSWER- D What is a Manometer and in what units is it calibrated? A) A pressure gauge calibrated in psi B) A pressure testing instrument calibrated in ft. w.c. C) A pressure testing instrument calibrated in inches w.c. D) A glass tube filled with alcohol to measure gas pressure in psi - ANSWER- C An orifice opening in a natural gas orifice is _____ an orifice opening in an LP orifice of the same rating: A) Smaller than B) Same as C) Larger than D) Varies by manufacturer - ANSWER- C Clem is out servicing a special processing oven connected to natural gas, and using a hot surface glow coil ignitor. The customer claims that the oven does not heat up very long before it cuts out. Clem has checked the gas pressure under load, the voltage under load, the polarity of the lines, the amp draw of the glow coil, and after removing the glow coil checked its resistance which seemed OK. What did Clem do wrong? A) The voltage needed to be checked using only a digital voltmeter because of the electronics in the circuit B) The gas pressure also needed to be taken without a load C) The polarity could not have had anything to do with the problem D) The glow coil needed to be homed out while it was hot to show up any possible cracks in the ceramic - ANSWER- C

Content preview

GAS CFESA PRACTICE TEST ACTUAL 2025
WITH 100 QUESTIONS AND CORRECT
ANSWERS | ALREADY GRADED A+ |
GUARANTEED PASS | GAS CFESA FINAL
LATEST VERSION 2025 [BRAND NEW!!]




Measuring static gas pressure will tell you if you have sufficient gas ______ to
meet the required
nameplate data.
A) No load pressure
B) Volume
C) Pressure and volume
D) Gas flow - ANSWER- A


A running pressure measurement will tell you if you have sufficient gas _______
to allow the gas
fired equipment to operate properly.
A) No load pressure
B) Volume
C) Pressure and volume
D) Gas flow - ANSWER- C

,The minimum incoming gas pressure, before a gas pressure regulator, must be
_______.
A) The operating pressure rating on the equipment data plate
B) Determines by the utility company
C) At least 1 in w.c. above the required operating pressure
D) At least 5 in w.c. above the required operating pressure - ANSWER- C


To properly take a gas pressure reading on a piece of gas fired equipment all of the
burners ___?
A) Should be turned off
B) Must be clean
C) Must be set to a bypass flame height
D) Must be turned full on - ANSWER- D


What is a Manometer and in what units is it calibrated?
A) A pressure gauge calibrated in psi
B) A pressure testing instrument calibrated in ft. w.c.
C) A pressure testing instrument calibrated in inches w.c.
D) A glass tube filled with alcohol to measure gas pressure in psi - ANSWER- C


An orifice opening in a natural gas orifice is _____ an orifice opening in an LP
orifice of the same
rating:
A) Smaller than
B) Same as
C) Larger than

,D) Varies by manufacturer - ANSWER- C


Clem is out servicing a special processing oven connected to natural gas, and using
a hot surface
glow coil ignitor. The customer claims that the oven does not heat up very long
before it cuts
out. Clem has checked the gas pressure under load, the voltage under load, the
polarity of the
lines, the amp draw of the glow coil, and after removing the glow coil checked its
resistance
which seemed OK. What did Clem do wrong?
A) The voltage needed to be checked using only a digital voltmeter because of the
electronics
in the circuit
B) The gas pressure also needed to be taken without a load
C) The polarity could not have had anything to do with the problem
D) The glow coil needed to be homed out while it was hot to show up any possible
cracks in the
ceramic - ANSWER- C


Joe's diner has a millivolt-operated gas-fired deep fryer. The pilot goes out from
time to time.
Sally tech has taken the following reading from the fryer with her meter connected
under load.
Thermopile output 300 MV with the fryer operating at 350* degrees F. There is no
apparent
makeup or exhaust air problems. The most likely problem is ______.
A) A thermopile is breaking down

, B) The gas valve magnet is breaking down
C) The pilot flame is to high
D) The limit thermostat is opening and prematurely breaking the circuit through
the
thermopile - ANSWER- A


A Keating fryer has a pilot valve that is locked into the circuit through a mercury
vapor switch.
The pilot will not stay lit when the momentary switch is released indicating that the
mercury
switch contacts are not closing. Before changing the switch Joe should do which of
the
following?
A) Make sure that sensor is in the outer most part of the pilot flame
B) Make sure that the tip of the sensor is being heated cherry red by the pilot flame
C) Check to ensure that the gas pressure is not too low
D) Make sure that the sensor is positioned away from the direct pilot flames so that
it does not
overheat - ANSWER- B


The purpose of a draft hood/draft diverter is_______?
A) To prevent drafts from entering the burner compartment that comes from the
power cent
hoods.
B) To prevent the combustion chamber from overheating, and allowing air to come
down the
vent pipe into the room.

Document information

Uploaded on
February 21, 2025
Number of pages
34
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$21.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
53
Followers
5
Items
1156
Last sold
3 weeks ago

Reviews from verified buyers



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions