100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Urinalysis and Body Fluids Exam |144 Q’s and A’s

Beoordeling
-
Verkocht
-
Pagina's
10
Cijfer
A+
Geüpload op
16-02-2025
Geschreven in
2024/2025

Urinalysis and Body Fluids Exam |144 Q’s and A’s

Instelling
Urinalysis And Body Fluids
Vak
Urinalysis and Body Fluids









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Urinalysis and Body Fluids
Vak
Urinalysis and Body Fluids

Documentinformatie

Geüpload op
16 februari 2025
Aantal pagina's
10
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Urinalysis and Body Fluids Exam |144 Q’s and
A’s
After receiving a 24-hour urine for quantitative total protein analysis, the
technician must first: - -Measure the total volume

- False results in urobilinogen testing may occur if the urine specimen is: - -
Exposed to light

- A clean-catch urine is submitted to the laboratory for routine urinalysis and
culture. The routine urinalysis is done first, and 3 hours later, the specimen is
sent to the microbiology department for culture. The specimen should: - -Be
rejected due to the time delay

- Which of the following urine results is most apt to be changed by
prolonged exposure to light? - -Bilirubin

- Urine samples should be examined within 1 hour of voiding because: - -
Bacterial contamination will cause alkalinization of the urine

- A urine specimen comes to the laboratory 7 hours after it is obtained. It is
acceptable for culture only if the specimen has been stored: - -At 4*-7*C

- Which of the following would be affected by allowing a urine specimen to
remain at room temperature for 3 hours before analysis? - -pH

- Failure to observe RBC casts in a urine specimen can be caused by: - -
Centrifuging an unmixed specimen

- The creatinine clearance is reported in: - -mL/min

- Microalbumin can be measured by a random urine collection. An increased
microalbumin is predictive of: - -Nephropathy

- A patient with uncontrolled diabetes mellitus will most likely have: - -Pale
urine with a high specific gravity

- While performing an analysis of a baby's urine, the technologist notices the
specimen to have a "mousy" odor. Of the following substances that may be
excreted in urine, the one that most characteristically produces this odor is: -
-Phenylpyruvic acid

- Urine that develops a port wine color after standing may contain: - -
Porphyrins

, - Urine from a 50-year-old man was noted to turn dark red on standing. This
change is caused by: - -Porphyrins

- The clarity of a urine sample should be determined: - -Following thorough
mixing of the specimen

- Milky urine from a 24-year-old woman would most likely contain: - -Many
white blood cells

- A brown-black urine would most likely contain: - -Melanin

- The yellow color of urine is primarily due to: - -Urochrome pigment

- Red urine may be due to: - -Myoglobin

- Urine osmolality is related to: - -Specific gravity

- Urine specific gravity is an index of the ability of the kidney to: - -
Concentrate the urine

- Osmolality is a measure of: - -Dissolved particles, including ions

- To prepare a solution appropriate for quality control of the refractometer, a
technician should use: - -Sodium chloride with a specific gravity of 1.022

- A urine's specific gravity is directly proportional to its: - -Dissolved solids

- Use of a refractometer over a urinometer is preferred due to the fact that
the refractometer uses: - -Small volume of urine and compensates for
temperature

- The method of choice for performing a specific gravity measurement of
urine following administration of x-ray contrast dyes is: - -Reagent strip

- Upon standing at room temperature, a urine pH typically: - -Increases

- Urine reagent strips should be stored in a(n): - -Cool dry area

- The protein section of the urine reagent strip is most sensitive to: - -
Albumin

- Which of the following reagents is used to react with ketones in the urine? -
-Sodium nitroprusside

- A reagent strip area impregnated with stabilized, diazotized 2,4-
dichloroaniline will yield a positive reaction with: - -Bilirubin

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
AccurateScores Not yet listed
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
552
Lid sinds
3 jaar
Aantal volgers
336
Documenten
15259
Laatst verkocht
5 dagen geleden

3.7

113 beoordelingen

5
51
4
18
3
18
2
11
1
15

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen