ET ASNT LEVEL I EXAM NEWEST 2025 ACTUAL EXAM COMPLETE
100 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED
ANSWERS) |ALREADY GRADED A+
I. A test specimen used as a basis for calibrating test cquipment or as a comparison when
evaluating test results is referred to as a:
a. null-balancer
b. phase shifter .
C. reference standard
d. high pass filter - (answers).C. reference standard
In an eddy current testing situation, which of the following can provide sources of noise?
a. instrumentation electronic circuits
b. nonspecific variations within the test object
c. electrical interference
d. all of the above - (answers).d. all of the above
3. The ratio of the response or amplitude from signals of interest to the response or amplitude of
indications that contain no useful information for the test being conducted is referred to as:
a. Poisson's ratio 你是想要一篇“眼睛容易
b. signal-to-noise ratio 阅读的”中文文章
c. the conductivity-to-permeability ratio
d. the reactance-to-resistance ratio - (answers)b. signal-to-noise ratio
4. IACS is a recognized abbreviation for:
a. Induced Alternating Current System
b. Inductively-Activated Comparison System
c. Internal Applied Current System
,d. International Annealed Copper Standard - (answers)d. International Annealed Copper Standard
Which of the following is not a basic component of eddy current equipment?
a. amplifier
b. coil
c. liquid couplant
d. detector - (answers)c. liquid couplant
The process of comparing the reading or output of an instrument, device, or dial with a standard
to determine the instrument's accuracy, capacity, or graduations is referred to as:
a. calibration
b. differentiation
c. integration
d. phase shifting - (answers)a. calibration
When'conducting an eddy current test using a differential comparison coil arrangement that
compares an external reference standard with the test specimen, the system should be nulled or
balanced:
a. with only the reference standard in one coil
b. with the reference standard in one coil and an acceptable test specimen in the other coil
c. with the reference standard in one你是想要一篇“眼睛容易
coil and an unacceptable test specimen in the other coil
d. with only the test specimen in one阅读的”中文文章
coil - (answers)b. with the reference standard in one coil
and an acceptable test specimen in the other coil
The impedance of an eddy current test coil will increase if the:
a. test frequency increases
b. inductive reactance of the coil decreases
c. inductance of the coil decreases
d. resistance of the coil decreases - (answers)• a. test frequency increases
, Some of the products commonly tested using encircling coils are:
a. rods, tubes, and wire
b. plate when volumetrically inspected
c. sheets and metalized foil
d. al of the above - (answers)a. rods, tubes, and wire
Which of the following would normally be considered the best fill factor when testing straight
tubing with an encircling or feedthrough coil?
a. 0.95 (95%)
b. 1.75 (175%)
c. 0.50 (50%)
d. 0.25 (25%) - (answers)a. 0.95 (95%
When a magnetic metal part is placed in an eddy current test coil, the impedance of the coil will
be changed by which of the following properties of the part?
a. conductivity
b. dimensions
c. permeability
d. all of the above - (answers)•d. all of the above
你是想要一篇“眼睛容易
An eddy current is a circulating electrical current induced in a conducting article by:
阅读的”中文文章
а. gamma rays
b. an alternating magnetic field
c. a piezoelectric force
d. any of the above - (answers)b. an alternating magnetic field
The conductivity of a material can be changed by changing the:
a. alloy of the specimen
b. heat treatment of the specimen
100 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED
ANSWERS) |ALREADY GRADED A+
I. A test specimen used as a basis for calibrating test cquipment or as a comparison when
evaluating test results is referred to as a:
a. null-balancer
b. phase shifter .
C. reference standard
d. high pass filter - (answers).C. reference standard
In an eddy current testing situation, which of the following can provide sources of noise?
a. instrumentation electronic circuits
b. nonspecific variations within the test object
c. electrical interference
d. all of the above - (answers).d. all of the above
3. The ratio of the response or amplitude from signals of interest to the response or amplitude of
indications that contain no useful information for the test being conducted is referred to as:
a. Poisson's ratio 你是想要一篇“眼睛容易
b. signal-to-noise ratio 阅读的”中文文章
c. the conductivity-to-permeability ratio
d. the reactance-to-resistance ratio - (answers)b. signal-to-noise ratio
4. IACS is a recognized abbreviation for:
a. Induced Alternating Current System
b. Inductively-Activated Comparison System
c. Internal Applied Current System
,d. International Annealed Copper Standard - (answers)d. International Annealed Copper Standard
Which of the following is not a basic component of eddy current equipment?
a. amplifier
b. coil
c. liquid couplant
d. detector - (answers)c. liquid couplant
The process of comparing the reading or output of an instrument, device, or dial with a standard
to determine the instrument's accuracy, capacity, or graduations is referred to as:
a. calibration
b. differentiation
c. integration
d. phase shifting - (answers)a. calibration
When'conducting an eddy current test using a differential comparison coil arrangement that
compares an external reference standard with the test specimen, the system should be nulled or
balanced:
a. with only the reference standard in one coil
b. with the reference standard in one coil and an acceptable test specimen in the other coil
c. with the reference standard in one你是想要一篇“眼睛容易
coil and an unacceptable test specimen in the other coil
d. with only the test specimen in one阅读的”中文文章
coil - (answers)b. with the reference standard in one coil
and an acceptable test specimen in the other coil
The impedance of an eddy current test coil will increase if the:
a. test frequency increases
b. inductive reactance of the coil decreases
c. inductance of the coil decreases
d. resistance of the coil decreases - (answers)• a. test frequency increases
, Some of the products commonly tested using encircling coils are:
a. rods, tubes, and wire
b. plate when volumetrically inspected
c. sheets and metalized foil
d. al of the above - (answers)a. rods, tubes, and wire
Which of the following would normally be considered the best fill factor when testing straight
tubing with an encircling or feedthrough coil?
a. 0.95 (95%)
b. 1.75 (175%)
c. 0.50 (50%)
d. 0.25 (25%) - (answers)a. 0.95 (95%
When a magnetic metal part is placed in an eddy current test coil, the impedance of the coil will
be changed by which of the following properties of the part?
a. conductivity
b. dimensions
c. permeability
d. all of the above - (answers)•d. all of the above
你是想要一篇“眼睛容易
An eddy current is a circulating electrical current induced in a conducting article by:
阅读的”中文文章
а. gamma rays
b. an alternating magnetic field
c. a piezoelectric force
d. any of the above - (answers)b. an alternating magnetic field
The conductivity of a material can be changed by changing the:
a. alloy of the specimen
b. heat treatment of the specimen