P-13 BULK OIL STORAGE FACILITY

________ SHALL NOT PASS THROUGH ADJACENT DIKED AREAS OR IMPOUNDING
BASINS. - ANS-PIPING
________ VALVES OR BLOCK VALVES ARE USED FOR AUTOMATIC PROTECTION
AGAINST BACKFLOW WHERE THE PIPING ARRANGEMENT IS SUCH THAT
BACKFLOW IS POSSIBLE. - ANS-CHECK
__________ SHALL NOT BE PAINTED. - ANS-SPRINKLERS
___________ IS A PRACTICE OF FUELING FROM ONE TRUCK TO ANOTHER. IT IS
NOT ALLOWED. - ANS-WET HOSE
___________ TANKS MAY BE USED TO STORE PRODUCTS WITH HIGH FLASH
POINTS. - ANS-CONE ROOF
____________ PUMPS MAY BE USED AS A SECONDARY SUPPLY SOURCE IF THE
PRIMARY SUPPLY WILL LAST LONG ENOUGH TO ALLOW THE PUMP TO BE
STARTED. - ANS-MANUALLY STARTED
____________ VALVES ARE USED TO OPEN AND CLOSE THE WATER SUPPLY IN
LARGE FACILITIES. - ANS-POST INDICATOR
_____________ SYSTEMS ARE VERY EFFECTIVE AND ARE THE MOST COMMON
METHOD OF FIGHTING FIRES IN BULK-OIL FACILITIES. - ANS-FOAM
______________ IS A VALVE THAT AUTOMATICALLY CLOSES IF NOT HELD OPEN BY
AN OPERATOR. - ANS-DEADMAN VALVE
"NO-SMOKING SIGNS SHALL NOT HAVE LETTERS OF LESS THAN _________ INCHES.
- ANS-4
A _________ IS A STRUCTURE ON THE SHORE OF A HARBOR WHERE
SHIPS/BARGES MAY DOCK TO LOAD AND UNLOAD CARGO. - ANS-WHARF
A __________ SYSTEM MAY BE INSTALLED WHEN A CONE ROOF IS USED TO STORE
PRODUCTS WITH A LOW FLASH POINT. - ANS-VAPOR RECOVERY SYSTEM
A ____________ SHALL BE CONDUCTED BY THE RESPONSIBLE PERSON PRIOR TO
WORK TO ENSURE THAT ALL EQUIPMENT IS SAFE. - ANS-PRE-HOT WORK CHECK
A FULL FLOW TEST IS PART OF THE ___________ PERFORMANCE TEST. -
ANS-2-YEAR
A STANDING WATER TEST SHALL BE MAINTAINED FOR NOT LESS THAN
___________ HOURS. - ANS-24
ABOVEGROUND VERTICAL CYLINDRICAL TANKS STORING COMBUSTIBLE LIQUIDS
SHALL NOT EXCEED ______________ FEET. - ANS-48
AFTER THE 2-YEAR FIRE SUPPRESSION SYSTEMS TEST, THE FOAM SYSTEM MUST
BE PROPERLY DRAINED AND ___________. - ANS-FLUSHED WITH WATER
ALL FIRE EXTINGUISHERS MUST BE SERVICED BY A ____________ AT LEAST ONCE
PER YEAR. - ANS-FDNY APPROVED COMPANY OR W-96 COF HOLDER
ALL FIRE PROTECTION PIPING SHALL BE PAINTED __________. - ANS-RED
ALL RECORDS SHOULD BE KEPT FOR AT LEAST ___________ YEARS. - ANS-5
ALL VALVES SHALL BE INSPECTED TO VERIFY THAT THE _____________ ARE NOT
MISSING. - ANS-REDUCER AND CAP

, AN EXTRA SUPPLY OF AT LEAST _________ SPRINKLER HEADS MUST BE KEPT
AVAILABLE AT ALL TIMES. - ANS-6
ANYTIME A TANK IS ALTERED OR REPAIRED, IT IS SUBJECT TO A ____________
STANDING WATER TEST. - ANS-24 HOUR
APPLYING THE FOAM GENTLY AT A CONTROLLED RATE WILL REDUCE THE TIME TO
____________. - ANS-EXTINGUISH THE FIRE
APPROVED AUTOMATIC OR MANUAL SHUTOFF VALVES SHALL BE PROVIDED
WHERE THE TRANSFER HOSE CONNECTS TO _________ PIPING. - ANS-PROCESS
AUTOMATIC SPRINKLER SYSTEMS SHALL BE IDENTIFIED BY ___________ BANDS
AND CONNECTION CAPS. - ANS-GREEN
BRODIE VALVES AUTOMATICALLY CLOSE WHEN THE TANK IS _________ PERCENT
FULL OR SOONER. - ANS-95
BY PERMANANENTLY BONDING PIPE TO AT LEAST ONE RAIL AND TO THE
TRANSFER APPARATUS, YOU WILL PROTECT AGAINST ___________. - ANS-STRAY
CURRENTS.
CABINETS WITH PORTABLE FIRE EXTINGUISHERS SHALL BE MARKED WITH THE
WORDS "FIRE EXTINGUISHER" IN LETTERS AT LEAST ________ INCHES HIGH. -
ANS-2
CARBON DIOXIDE EXTINGUISHING SYSTEMS SHALL BE IDENTIFIED BY __________
BANDS. - ANS-BLACK
CARGO TANKS/TANK TRUCKS SHALL NEVER BE LOCATED _________ WHILE
TRANSFERRING CLASS 1, 2, OR 3 LIQUIDS. - ANS-INDOORS
CHECK VALVES SHALL BE INSPECTED INTERNALLY EVERY _________ YEARS. -
ANS-5
COF HOLDER MUST REPORT TO AND FOLLOW THE INSTRUCTIONS ISSUED BY THE
____________. - ANS-COAST GUARD
DEFECTIVE EXTINGUISHERS MUST BE ______________. - ANS-REPAIRED OR
REPLACED.
DEPARTMENT FOAM CONNECTIONS SHALL BE IDENTIFIED BY __________ BANDS
OR CAPS. - ANS-ORANGE
DEPARTMENT WATER CONNECTIONS FOR FOAM EXTINGUISHING SYSTEMS SHALL
HAVE A ___________ POSTED IMMEDIATELY ADJACENT TO CONNECTIONS. -
ANS-SIGN
DEPENDING ON THE PRODUCT SERVICE, INTERIOR OF TANKS SHALL BE
INSPECTED EVERY ____________ YEARS. - ANS-10
DOCKING SHALL BE CONSTRUCTED TO WITHSTAND ______________. - ANS-SHOCK,
EXCESS MOVEMENT, AND FIRE
DURING AN EMERGENCY SHUTDOWN TEST, THE __________ DO NOT GET
SHUTDOWN. - ANS-PHONE LINES
EACH NORMALLY OPEN VALVE SHALL BE SEALED OR _____________. -
ANS-ELECTRICALLY SUPERVISED
EACH POUND OF ABSORBENT MATERIAL MUST BE CAPABLE OF ABSORBING
_________ OF THE SPILLED PRODUCT. - ANS-ONE HALF GALLON
EACH SINGLE DIKE WALL ENCLOSURE SHALL HAVE A CAPACITY EQUAL TO
_________ PERCENT OF THE TANK'S CAPACITY. - ANS-110
EMERGENCY SHUT-OFF VALVES USED IN SOME MOUNDED-OVER TANKS MUST
CONTAIN A ___________ LINK. - ANS-FUSIBLE

Document information

Uploaded on
February 12, 2025
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Purity96
3.1
(16)
Sold
89
Followers
20
Items
1174
Last sold
1 week ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions