P-13 BULK OIL STORAGE FACILITY
________ SHALL NOT PASS THROUGH ADJACENT DIKED AREAS OR IMPOUNDING
BASINS. - ANS-PIPING
________ VALVES OR BLOCK VALVES ARE USED FOR AUTOMATIC PROTECTION
AGAINST BACKFLOW WHERE THE PIPING ARRANGEMENT IS SUCH THAT
BACKFLOW IS POSSIBLE. - ANS-CHECK
__________ SHALL NOT BE PAINTED. - ANS-SPRINKLERS
___________ IS A PRACTICE OF FUELING FROM ONE TRUCK TO ANOTHER. IT IS
NOT ALLOWED. - ANS-WET HOSE
___________ TANKS MAY BE USED TO STORE PRODUCTS WITH HIGH FLASH
POINTS. - ANS-CONE ROOF
____________ PUMPS MAY BE USED AS A SECONDARY SUPPLY SOURCE IF THE
PRIMARY SUPPLY WILL LAST LONG ENOUGH TO ALLOW THE PUMP TO BE
STARTED. - ANS-MANUALLY STARTED
____________ VALVES ARE USED TO OPEN AND CLOSE THE WATER SUPPLY IN
LARGE FACILITIES. - ANS-POST INDICATOR
_____________ SYSTEMS ARE VERY EFFECTIVE AND ARE THE MOST COMMON
METHOD OF FIGHTING FIRES IN BULK-OIL FACILITIES. - ANS-FOAM
______________ IS A VALVE THAT AUTOMATICALLY CLOSES IF NOT HELD OPEN BY
AN OPERATOR. - ANS-DEADMAN VALVE
"NO-SMOKING SIGNS SHALL NOT HAVE LETTERS OF LESS THAN _________ INCHES.
- ANS-4
A _________ IS A STRUCTURE ON THE SHORE OF A HARBOR WHERE
SHIPS/BARGES MAY DOCK TO LOAD AND UNLOAD CARGO. - ANS-WHARF
A __________ SYSTEM MAY BE INSTALLED WHEN A CONE ROOF IS USED TO STORE
PRODUCTS WITH A LOW FLASH POINT. - ANS-VAPOR RECOVERY SYSTEM
A ____________ SHALL BE CONDUCTED BY THE RESPONSIBLE PERSON PRIOR TO
WORK TO ENSURE THAT ALL EQUIPMENT IS SAFE. - ANS-PRE-HOT WORK CHECK
A FULL FLOW TEST IS PART OF THE ___________ PERFORMANCE TEST. -
ANS-2-YEAR
A STANDING WATER TEST SHALL BE MAINTAINED FOR NOT LESS THAN
___________ HOURS. - ANS-24
ABOVEGROUND VERTICAL CYLINDRICAL TANKS STORING COMBUSTIBLE LIQUIDS
SHALL NOT EXCEED ______________ FEET. - ANS-48
AFTER THE 2-YEAR FIRE SUPPRESSION SYSTEMS TEST, THE FOAM SYSTEM MUST
BE PROPERLY DRAINED AND ___________. - ANS-FLUSHED WITH WATER
ALL FIRE EXTINGUISHERS MUST BE SERVICED BY A ____________ AT LEAST ONCE
PER YEAR. - ANS-FDNY APPROVED COMPANY OR W-96 COF HOLDER
ALL FIRE PROTECTION PIPING SHALL BE PAINTED __________. - ANS-RED
ALL RECORDS SHOULD BE KEPT FOR AT LEAST ___________ YEARS. - ANS-5
ALL VALVES SHALL BE INSPECTED TO VERIFY THAT THE _____________ ARE NOT
MISSING. - ANS-REDUCER AND CAP
, AN EXTRA SUPPLY OF AT LEAST _________ SPRINKLER HEADS MUST BE KEPT
AVAILABLE AT ALL TIMES. - ANS-6
ANYTIME A TANK IS ALTERED OR REPAIRED, IT IS SUBJECT TO A ____________
STANDING WATER TEST. - ANS-24 HOUR
APPLYING THE FOAM GENTLY AT A CONTROLLED RATE WILL REDUCE THE TIME TO
____________. - ANS-EXTINGUISH THE FIRE
APPROVED AUTOMATIC OR MANUAL SHUTOFF VALVES SHALL BE PROVIDED
WHERE THE TRANSFER HOSE CONNECTS TO _________ PIPING. - ANS-PROCESS
AUTOMATIC SPRINKLER SYSTEMS SHALL BE IDENTIFIED BY ___________ BANDS
AND CONNECTION CAPS. - ANS-GREEN
BRODIE VALVES AUTOMATICALLY CLOSE WHEN THE TANK IS _________ PERCENT
FULL OR SOONER. - ANS-95
BY PERMANANENTLY BONDING PIPE TO AT LEAST ONE RAIL AND TO THE
TRANSFER APPARATUS, YOU WILL PROTECT AGAINST ___________. - ANS-STRAY
CURRENTS.
CABINETS WITH PORTABLE FIRE EXTINGUISHERS SHALL BE MARKED WITH THE
WORDS "FIRE EXTINGUISHER" IN LETTERS AT LEAST ________ INCHES HIGH. -
ANS-2
CARBON DIOXIDE EXTINGUISHING SYSTEMS SHALL BE IDENTIFIED BY __________
BANDS. - ANS-BLACK
CARGO TANKS/TANK TRUCKS SHALL NEVER BE LOCATED _________ WHILE
TRANSFERRING CLASS 1, 2, OR 3 LIQUIDS. - ANS-INDOORS
CHECK VALVES SHALL BE INSPECTED INTERNALLY EVERY _________ YEARS. -
ANS-5
COF HOLDER MUST REPORT TO AND FOLLOW THE INSTRUCTIONS ISSUED BY THE
____________. - ANS-COAST GUARD
DEFECTIVE EXTINGUISHERS MUST BE ______________. - ANS-REPAIRED OR
REPLACED.
DEPARTMENT FOAM CONNECTIONS SHALL BE IDENTIFIED BY __________ BANDS
OR CAPS. - ANS-ORANGE
DEPARTMENT WATER CONNECTIONS FOR FOAM EXTINGUISHING SYSTEMS SHALL
HAVE A ___________ POSTED IMMEDIATELY ADJACENT TO CONNECTIONS. -
ANS-SIGN
DEPENDING ON THE PRODUCT SERVICE, INTERIOR OF TANKS SHALL BE
INSPECTED EVERY ____________ YEARS. - ANS-10
DOCKING SHALL BE CONSTRUCTED TO WITHSTAND ______________. - ANS-SHOCK,
EXCESS MOVEMENT, AND FIRE
DURING AN EMERGENCY SHUTDOWN TEST, THE __________ DO NOT GET
SHUTDOWN. - ANS-PHONE LINES
EACH NORMALLY OPEN VALVE SHALL BE SEALED OR _____________. -
ANS-ELECTRICALLY SUPERVISED
EACH POUND OF ABSORBENT MATERIAL MUST BE CAPABLE OF ABSORBING
_________ OF THE SPILLED PRODUCT. - ANS-ONE HALF GALLON
EACH SINGLE DIKE WALL ENCLOSURE SHALL HAVE A CAPACITY EQUAL TO
_________ PERCENT OF THE TANK'S CAPACITY. - ANS-110
EMERGENCY SHUT-OFF VALVES USED IN SOME MOUNDED-OVER TANKS MUST
CONTAIN A ___________ LINK. - ANS-FUSIBLE
________ SHALL NOT PASS THROUGH ADJACENT DIKED AREAS OR IMPOUNDING
BASINS. - ANS-PIPING
________ VALVES OR BLOCK VALVES ARE USED FOR AUTOMATIC PROTECTION
AGAINST BACKFLOW WHERE THE PIPING ARRANGEMENT IS SUCH THAT
BACKFLOW IS POSSIBLE. - ANS-CHECK
__________ SHALL NOT BE PAINTED. - ANS-SPRINKLERS
___________ IS A PRACTICE OF FUELING FROM ONE TRUCK TO ANOTHER. IT IS
NOT ALLOWED. - ANS-WET HOSE
___________ TANKS MAY BE USED TO STORE PRODUCTS WITH HIGH FLASH
POINTS. - ANS-CONE ROOF
____________ PUMPS MAY BE USED AS A SECONDARY SUPPLY SOURCE IF THE
PRIMARY SUPPLY WILL LAST LONG ENOUGH TO ALLOW THE PUMP TO BE
STARTED. - ANS-MANUALLY STARTED
____________ VALVES ARE USED TO OPEN AND CLOSE THE WATER SUPPLY IN
LARGE FACILITIES. - ANS-POST INDICATOR
_____________ SYSTEMS ARE VERY EFFECTIVE AND ARE THE MOST COMMON
METHOD OF FIGHTING FIRES IN BULK-OIL FACILITIES. - ANS-FOAM
______________ IS A VALVE THAT AUTOMATICALLY CLOSES IF NOT HELD OPEN BY
AN OPERATOR. - ANS-DEADMAN VALVE
"NO-SMOKING SIGNS SHALL NOT HAVE LETTERS OF LESS THAN _________ INCHES.
- ANS-4
A _________ IS A STRUCTURE ON THE SHORE OF A HARBOR WHERE
SHIPS/BARGES MAY DOCK TO LOAD AND UNLOAD CARGO. - ANS-WHARF
A __________ SYSTEM MAY BE INSTALLED WHEN A CONE ROOF IS USED TO STORE
PRODUCTS WITH A LOW FLASH POINT. - ANS-VAPOR RECOVERY SYSTEM
A ____________ SHALL BE CONDUCTED BY THE RESPONSIBLE PERSON PRIOR TO
WORK TO ENSURE THAT ALL EQUIPMENT IS SAFE. - ANS-PRE-HOT WORK CHECK
A FULL FLOW TEST IS PART OF THE ___________ PERFORMANCE TEST. -
ANS-2-YEAR
A STANDING WATER TEST SHALL BE MAINTAINED FOR NOT LESS THAN
___________ HOURS. - ANS-24
ABOVEGROUND VERTICAL CYLINDRICAL TANKS STORING COMBUSTIBLE LIQUIDS
SHALL NOT EXCEED ______________ FEET. - ANS-48
AFTER THE 2-YEAR FIRE SUPPRESSION SYSTEMS TEST, THE FOAM SYSTEM MUST
BE PROPERLY DRAINED AND ___________. - ANS-FLUSHED WITH WATER
ALL FIRE EXTINGUISHERS MUST BE SERVICED BY A ____________ AT LEAST ONCE
PER YEAR. - ANS-FDNY APPROVED COMPANY OR W-96 COF HOLDER
ALL FIRE PROTECTION PIPING SHALL BE PAINTED __________. - ANS-RED
ALL RECORDS SHOULD BE KEPT FOR AT LEAST ___________ YEARS. - ANS-5
ALL VALVES SHALL BE INSPECTED TO VERIFY THAT THE _____________ ARE NOT
MISSING. - ANS-REDUCER AND CAP
, AN EXTRA SUPPLY OF AT LEAST _________ SPRINKLER HEADS MUST BE KEPT
AVAILABLE AT ALL TIMES. - ANS-6
ANYTIME A TANK IS ALTERED OR REPAIRED, IT IS SUBJECT TO A ____________
STANDING WATER TEST. - ANS-24 HOUR
APPLYING THE FOAM GENTLY AT A CONTROLLED RATE WILL REDUCE THE TIME TO
____________. - ANS-EXTINGUISH THE FIRE
APPROVED AUTOMATIC OR MANUAL SHUTOFF VALVES SHALL BE PROVIDED
WHERE THE TRANSFER HOSE CONNECTS TO _________ PIPING. - ANS-PROCESS
AUTOMATIC SPRINKLER SYSTEMS SHALL BE IDENTIFIED BY ___________ BANDS
AND CONNECTION CAPS. - ANS-GREEN
BRODIE VALVES AUTOMATICALLY CLOSE WHEN THE TANK IS _________ PERCENT
FULL OR SOONER. - ANS-95
BY PERMANANENTLY BONDING PIPE TO AT LEAST ONE RAIL AND TO THE
TRANSFER APPARATUS, YOU WILL PROTECT AGAINST ___________. - ANS-STRAY
CURRENTS.
CABINETS WITH PORTABLE FIRE EXTINGUISHERS SHALL BE MARKED WITH THE
WORDS "FIRE EXTINGUISHER" IN LETTERS AT LEAST ________ INCHES HIGH. -
ANS-2
CARBON DIOXIDE EXTINGUISHING SYSTEMS SHALL BE IDENTIFIED BY __________
BANDS. - ANS-BLACK
CARGO TANKS/TANK TRUCKS SHALL NEVER BE LOCATED _________ WHILE
TRANSFERRING CLASS 1, 2, OR 3 LIQUIDS. - ANS-INDOORS
CHECK VALVES SHALL BE INSPECTED INTERNALLY EVERY _________ YEARS. -
ANS-5
COF HOLDER MUST REPORT TO AND FOLLOW THE INSTRUCTIONS ISSUED BY THE
____________. - ANS-COAST GUARD
DEFECTIVE EXTINGUISHERS MUST BE ______________. - ANS-REPAIRED OR
REPLACED.
DEPARTMENT FOAM CONNECTIONS SHALL BE IDENTIFIED BY __________ BANDS
OR CAPS. - ANS-ORANGE
DEPARTMENT WATER CONNECTIONS FOR FOAM EXTINGUISHING SYSTEMS SHALL
HAVE A ___________ POSTED IMMEDIATELY ADJACENT TO CONNECTIONS. -
ANS-SIGN
DEPENDING ON THE PRODUCT SERVICE, INTERIOR OF TANKS SHALL BE
INSPECTED EVERY ____________ YEARS. - ANS-10
DOCKING SHALL BE CONSTRUCTED TO WITHSTAND ______________. - ANS-SHOCK,
EXCESS MOVEMENT, AND FIRE
DURING AN EMERGENCY SHUTDOWN TEST, THE __________ DO NOT GET
SHUTDOWN. - ANS-PHONE LINES
EACH NORMALLY OPEN VALVE SHALL BE SEALED OR _____________. -
ANS-ELECTRICALLY SUPERVISED
EACH POUND OF ABSORBENT MATERIAL MUST BE CAPABLE OF ABSORBING
_________ OF THE SPILLED PRODUCT. - ANS-ONE HALF GALLON
EACH SINGLE DIKE WALL ENCLOSURE SHALL HAVE A CAPACITY EQUAL TO
_________ PERCENT OF THE TANK'S CAPACITY. - ANS-110
EMERGENCY SHUT-OFF VALVES USED IN SOME MOUNDED-OVER TANKS MUST
CONTAIN A ___________ LINK. - ANS-FUSIBLE