Lead Abatement State Test Supervisor

According to OSHA, at what heights is fall protection required when using a scaffold? -
ANS-10 feet
Characteristics of lead - ANS-Metal, Gray, Soft, Heavy, Blocks radiation & Toxic
Convert 400 ppm (ug/g) into percentage by weight - ANS-0.04%
Convert 5,000 ppm into percentage by weight - ANS-0.5%
Define abatement - ANS-Permanently eliminate lead-based paint hazards
Define interim control? - ANS-Temporary control of lead-based paint hazards
How can lead enter the body? - ANS-Eating & Breathing
How do we calculate the maximum use level of a respirator - ANS-Protection actor multiplied
by PEL (Protection factor X PEL)
How do we test for hazardous waste - ANS-Toxicity Characteristic Leachate Procedure
(TCLP)
How does the inspector determine whether interim control of soul has been successfully
performed? - ANS-Visual inspection
How does the inspector determine whether soil abatement has been successfully
performed? - ANS-Soil samples
How long does lead typically remain in soft tissue - ANS-30 days
How long does lead typically remain in the blood - ANS-30 days
How long does lead typically remain in the bones - ANS-30 years
How long may a conditionally exempt generator store contaminated waste? - ANS-90 days
How long must the contractor keep project records? - ANS-3 years
How may lead waste from a single family home be handled? - ANS-As household waste
How may we defend ourselves against a claim that we had been negligent? - ANS-Obey
applicable laws & we followed the standard of care of our industry.
How much deteriorated paint or dust is permitted when lead dust sampling is performed? -
ANS-None
How much lead contaminated waste makes a contractor a conditionally exempt waste
generator? - ANS-less than 220 pounds per month
How much lead must leach out of waste for it to be considered hazardous? - ANS-5PPM
HUD recommends separating types of waste, what does that mean? - ANS-Separating what
may be contaminated with lead with what is not contaminated with lead
If a heat gun is used, what is the temperature limit of the heat gun - ANS-1100 degrees F.
If an employee's blood lead level exceeds 40 ug/dl, what additional monitoring must be
provided to the employee? - ANS-back to back testing every 2 months
If an employee's blood level exceeds 50 ug/dl, what additional protection must be provided
by the employee? - ANS-medical removal protection
If exposure monitoring indicates that exposures are above the action level but below the PEL
for a job, how long may we rely on the monitoring for similar jobs? - ANS-6 months
If exposure monitoring indicates that exposures are above the PEL for a job, how long may
we rely on the monitoring for similar jobs? - ANS-3 months
If exposure monitoring indicates that exposures are below the action level for a job, how long
may we rely on the monitoring for similar jobs? - ANS-1 year

, If exposures are above the action level for any one day in a calendar year, what must the
employer provide its workers? - ANS-Blood test (Biological monitoring)
If exposures are above the action level for more than 30 days in a calendar year, what must
the employer provide its workers? - ANS-Medical surveillance, blood test every 2 months for
the first 6 months and every 6 months thereafter.
If exposures are above the PEL, what must the employer do first? - ANS-stop work and
re-evaluate work practices to reduce exposures
If exposures are below the action level, the employer must nevertheless perform two
additional things to protect workers. What? - ANS-Provide a hand washing facility & keep the
area free of dust & debris
If the employer cannot reduce exposures below the PEL then what must the employer
provide? - ANS-respiratory protection, full body clothing, shower & clean lunch and break
area.
If we cannot move occupants, what must we provide if we work while they are present? -
ANS-A way in and out, access and egress, access to bathroom, access to kitchen, blockage
to the work area
If we use a belt sander or any other kind of power device, what must we use with this
equipment? - ANS-Hepa vacuum attachment
Name five components commonly enclosed - ANS-Walls, stairs, floors, window casings &
exterior siding
Name four components commonly replaced - ANS-windows, doors, rotten stairs, fascia
boards
Name four methods of interim control - ANS-Education of occupants, paint stabilization,
specialized cleaning, mulching of soul
Name four methods of removal - ANS-Wet scraping, wet sanding, chemical stripping & use a
heat gun
Name four methods of removal that are prohibited - ANS-dry sanding/ scrapping, open flame
torching, heat guns over 1100F using methylene chloride
Name one example of soil interim control - ANS-Mulching
Name two examples of soul abatment - ANS-Removing & replacing soul covering with
concrete & asphalt
Three items provided on a Material Safety Data Sheet - ANS-Existence of hazards in a
product & first aid, Need for PPE when using the product & first aid response in case of
exposure.
What accreditation is required for the laboratory analyzing dust wipes? - ANS-National lead
laboratory accreditation program
What additional controls have to be considered when removing contaminated soil? -
ANS-Controlling wind & rain erosion
What amount of lead is regulated by OSHA? - ANS-any exposable amount
What are four symptoms of heat exhaustion - ANS-Cool sweaty skin, headache, dizziness &
nausea
What are four symptoms of heat stroke? - ANS-Hot dry skin, nausea, fainting & dizziness
What are important traits for a supervisor to communicate to workers? - ANS-Give clear
directions to workers, quickly correct mistakes, do not be derisive & emphasize team work
What are sources of lead contamination for yards and playgrounds? - ANS-Roof flashing,
leaded gas contamination, industrial emissions & paint dust from homes
What are symptoms of lead poisoning - ANS-Stomach aches, constipation or diarrhea,
irritability, fatigue & weakness, muscle aches, lack of sex drive, tremors & also headaches

Document information

Uploaded on
February 12, 2025
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Purity96
3.1
(16)
Sold
89
Followers
20
Items
1174
Last sold
1 week ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions