NATE AIR CONDITIONING AND HEAT PUMPS WITH ALL CORRECT ANSWERS Which of the following factors affects a customer's level of comfort? A. Air movement, B. Humidity, C. Temperature, D. All of the above - Answer-D. All of the above /.A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible capacity of a cooling-only system should be within ____% of this calculated value. a. ±10% b. +10% c. +15% d. +30% - Answer-C. +15% /.The maximum sensible cooling capacity of a heat pump should be within _________ % of the calculated sensible heat gain of a structure with a large heating load. A. +_ 10% B. + 15% C. -25% D. +25% - Answer-D. +25% /.The combined output of a heat pump and its auxiliary heat should not exceed the calculated heat loss of a home by more than ___________%. A. 10% B. 15% C. 20% D. 25% - Answer-B. 15% /.What amount of auxiliary electric heat is needed when the output of a heat pump on a design day equals 18,800 Btuh and the heat loss of a home is 29,700 Btuh? a. 2.1 kWh b. 3.2 kWh c. 5.0 kWh d. 10.9 kWh Note: 3,413 Btu/kW - Answer-b (3.2 kWh) /.The three processes that transfer that occurs when substances of different temperatures are in contact with each other is called _________. A. Concentration B. Conduction C. Convection D. Radiation - Answer-B. Conduction /.What effect does raising the pressure in a sealed system have on refrigerant? A. It becomes more difficult to subcool the liquid refrigerant B. It becomes more difficult to superheat the refrigerant vapor C. The refrigerant's boiling point decreases D. The refrigerant's boiling point increases - Answer-d (The refrigerant's boiling point increases) /.What is the primary danger to people near an accidental refrigerant release or spill? A. Blurred vision caused by the refrigerant vapor coming in contact with the eyes B. Changes in weather patterns caused by global warming C. Damage to the food chain caused by decreased ozone levels in the stratosphere D. Suffocation caused by the heavier refrigerant displacing oxygen in the air - Answer-d (Suffocation caused by the heavier refrigerant displacing oxygen in the air) /.The maximum temperature at which refrigerant may be stored is ________ •F when the container is no more than __________% full of liquid by volume. A. 120•F, 60% B. 125•F, 60% C. 125•F, 80% D. 135•F, 80% - Answer-C. 125•F, 80% /.Boiling of the refrigerant occurs in which system component? a. Compressor b. Condenser c. Evaporator d. Metering device - Answer-c (Evaporator) /.Why is superheat necessary in a system that utilizes hermetic compressors? a. It ensures that dry vapor reaches the compressor so that mechanical damage does not occur b. It increases system capacity c. It prevents liquid refrigerant from gassing the metering device d. Superheat is necessary only when open compressors are being used - Answer-a (It ensures that dry vapor reaches the compressor so that mechanical damage does not occur) /.When the heat load on an evaporator increases, what is the effect on the system? a. Suction pressure decreases and discharge pressure increases b. Suction pressure increases and discharge pressure decreases c. Suction pressure and discharge pressure both decrease d. Suction pressure and discharge pressure both increase - Answer-d (Suction pressure and discharge pressure both increase) /.What type of energy is transferred when work is done in the condenser? A. Latent heat energy B. Sensible heat energy C. Both latent and sensible heat energy D. Neither latent nor sensible heat energy - Answer-c (Both latent and sensible heat energy) /.What is the primary function performed by a thermal expansion valve? A. It maintains the correct superheat in the hot vapor leaving the compressor B. It maintains the correct superheat in the suction vapor leaving the evaporator C. It maintains the proper subcooling level in the liquid refrigerant D. It prevents flash vapor bubbles from developing in refrigerant entering the evaporator - Answer-B. It maintains the correct superheat in the suction vapor leaving the evaporator /.Which component pumps refrigerant through the system and raises the vapor temperature? A. Accumulator B. Compressor C. Condenser D. Evaporator - Answer-B. Compressor /.How are hermetic compressor motors cooled? a. With air drawn around the compressor shell by the condenser fan b. With water circulated through tubing wrapped around the compressor shell c. With suction vapor drawn from the evaporator d. With a combination of air and water - Answer-c (With suction vapor drawn from the evaporator) /.Heat pump compressors sometimes run hotter than compressors used in cooling-only units because heat pump compressors ____. a. exhibit low refrigerant density at low suction pressures during the heating cycle b. pump liquid refrigerant during the cooling cycle c. must prevent ice formation during the defrost cycle d. must heat indoor spaces in the winter - Answer-a (exhibit low refrigerant density at low suction) /.When is crankcase heat most needed? A. Early in the morning during the cooling cycle B. When the compressor is operating in very cold winter weather

Content preview

NATE AIR CONDITIONING AND HEAT
PUMPS WITH ALL CORRECT ANSWERS

Which of the following factors affects a customer's level of comfort? A. Air movement, B.
Humidity, C. Temperature, D. All of the above - Answer-D. All of the above

/.A cooling load calculation estimates the sensible heat gain of a structure. The
maximum sensible capacity of a cooling-only system should be within ____% of this
calculated value.

a. ±10%
b. +10%
c. +15%
d. +30% - Answer-C. +15%

/.The maximum sensible cooling capacity of a heat pump should be within _________
% of the calculated sensible heat gain of a structure with a large heating load.
A. +_ 10%
B. + 15%
C. -25%
D. +25% - Answer-D. +25%

/.The combined output of a heat pump and its auxiliary heat should not exceed the
calculated heat loss of a home by more than ___________%.
A. 10%
B. 15%
C. 20%
D. 25% - Answer-B. 15%

/.What amount of auxiliary electric heat is needed when the output of a heat pump on a
design day equals 18,800 Btuh and the heat loss of a home is 29,700 Btuh?

a. 2.1 kWh
b. 3.2 kWh
c. 5.0 kWh
d. 10.9 kWh

Note: 3,413 Btu/kW - Answer-b (3.2 kWh)

/.The three processes that transfer that occurs when substances of different
temperatures are in contact with each other is called _________.
A. Concentration

, B. Conduction
C. Convection
D. Radiation - Answer-B. Conduction

/.What effect does raising the pressure in a sealed system have on refrigerant?
A. It becomes more difficult to subcool the liquid refrigerant
B. It becomes more difficult to superheat the refrigerant vapor
C. The refrigerant's boiling point decreases
D. The refrigerant's boiling point increases - Answer-d (The refrigerant's boiling point
increases)

/.What is the primary danger to people near an accidental refrigerant release or spill?
A. Blurred vision caused by the refrigerant vapor coming in contact with the eyes
B. Changes in weather patterns caused by global warming
C. Damage to the food chain caused by decreased ozone levels in the stratosphere
D. Suffocation caused by the heavier refrigerant displacing oxygen in the air - Answer-d
(Suffocation caused by the heavier refrigerant displacing oxygen in the air)

/.The maximum temperature at which refrigerant may be stored is ________ •F when
the container is no more than __________% full of liquid by volume.
A. 120•F, 60%
B. 125•F, 60%
C. 125•F, 80%
D. 135•F, 80% - Answer-C. 125•F, 80%

/.Boiling of the refrigerant occurs in which system component?

a. Compressor
b. Condenser
c. Evaporator
d. Metering device - Answer-c (Evaporator)

/.Why is superheat necessary in a system that utilizes hermetic compressors?

a. It ensures that dry vapor reaches the compressor so that mechanical damage does
not occur
b. It increases system capacity
c. It prevents liquid refrigerant from gassing the metering device
d. Superheat is necessary only when open compressors are being used - Answer-a (It
ensures that dry vapor reaches the compressor so that mechanical damage does not
occur)

/.When the heat load on an evaporator increases, what is the effect on the system?

a. Suction pressure decreases and discharge pressure increases
b. Suction pressure increases and discharge pressure decreases

Document information

Uploaded on
February 9, 2025
Number of pages
15
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brainariam
3.4
(29)
Sold
158
Followers
7
Items
8427
Last sold
4 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions