100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Master Electrician Class Exam 2025/2026 Questions With Completed & Verified Solutions.

Rating
-
Sold
-
Pages
9
Grade
A+
Uploaded on
04-02-2025
Written in
2024/2025

Master Electrician Class Exam 2025/2026 Questions With Completed & Verified Solutions.

Institution
Master Electrical
Course
Master Electrical









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Master Electrical
Course
Master Electrical

Document information

Uploaded on
February 4, 2025
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Master Electrician Class

#4 cooper & #2 Aluminum - ANS -What is the minimum size Service Conductor allowed for a
dwelling unit
\0.001 inch - ANS -One circular mil is the area of a circle whose diameter is:
\0.622" - ANS -The internal diameter of 1/2"EMT is:
\1 - ANS -At least_____ 125 V, single phase, 15 A or 20 A, duplex with ground-fault circuit
interrupter receptacle shall be provided in each elevator machine room and elevator machinery
space.
\1 1/2" - ANS -Flat:top underfloor raceways over 4 inches, but less 8 inches wide, with a
minimum 1 inch spacing between raceways, shall be covered with concrete to a depth of not
iess than 1 inch. Raceways spaced less that 1 inch apart shall be covered with a concrete to a
depth of
\1,000,000 CM - ANS -6. A round bus-bar one inch in diameter, has a circular mil area of:
\1.5" - ANS -The outside diameter of a threaded rigid conduit is measured to be about two
Inches. The nominal trade size is:
\10 AWG Copper - ANS -7. Service Lateral conductors that supply power to limited loads of a
single branch circuit-such as a small polyphase power, controlled water heaters, and similar
loads-shall not be smaller than
\10 feet - ANS -Nonmetallic cables can enter the top of surface-mounted cabinets, cutout boxes,
and meter socket enclosures through nonflexible raceways not less than 18 in. or more than
______ft in length if all of the required conditions are met.
\10 feet above grade level - ANS -Open conductors which are not service entrance cables shall
not be installed less than which of the following
\10.4 - ANS -The specific resistance of copper wire @ 20° C in ohms per circular mil ft. is
\10' - ANS -Lighting systems operating at 30V or less shall not be·installed within_______of
pools, spas, fountains, or similar locatipns
\1000A - ANS -20. Ground fault protection of equipment shall be provided for solidly grounded
wye electrical services of more than 150 volts-to-ground, but not exceeding 600V
phase-to-phase for each service
disconnecting means rated __________
\1000A - ANS -Ground-fault protection of equipment shall be provided fro solidly grounded wye
electrical services of more than 150 volts-to-ground, but not exceeding 600V phase-to..phase
for each service disconnecting means rated
\115% - ANS -A disconnecting means that serves a hermetic refrigerant motor compressor shall
have an ampere rating of at least percent of the nameplate rated load current or branch circuit
selection current, whichever is greater.
\116 Conductors - ANS -What is the Max number of #6 THHN current carrying conductors in 4"
EMT for general use is
\12 - ANS -How many# 10 conductors can be legally installed in a 4 inch square box, 2 1/8
deep?

, \12 /40 - ANS -Where communications wires and cables and electric light or power conductors
are supported by the same pole and are run paralled to each other in span , the·supply service
drops of 0-750 volts running above and parallel to communications service drops shall have a
minimum separation of _______inches at any point in the
span, including the point of and at their attachment to the building, provided the nongrounded
conductors are insulated and that a clearance of not less than_______ inches is maintained
between the two services at the pole
\12 AWG - ANS -Communications circuits shall have a minimum grounding conductor of
_____AWG
\12 feet - ANS -The verticaI clearance from ground level over a residential driveway for
overhead service conductors not subject to truck traffic and are less than 300 volts to ground
shall be _____ ft:
\12" - ANS -For cord and plug connected electric vehicle supply equipment is used, the
interrupting device of a
listed personnel protection system shall be provided and shall be located in the power supply
cable not more than ______from the attachment plug.
\12" - ANS -Underground service conductors that are not encased in concrete and that are
buried 30 inches or more below grade, shall have their location identified by a warning ribbon
that is placed in the trench at least_______inches above the underground installation for 40KV
\1200 Amperes - ANS -19. When an equipment room houses electrical equipment rated at
LEAST _____or more, the personnel doors intended for entrance to and egress from the
working space, shall open in the direction of egress.
\125% - ANS -Branch circuit conductor that supply a single motor used in a continuous duty
application shall have an ampacity of not less than Percent of the motors full-load current
\12Ft - ANS -6. Overhead feeder conductors shall have a minimum __________ vertical
clearance over residential property and driveways, as well as those commercial areas not
subject to truck traffic, where the voltage is limited to 300 volts-to-ground.
\13 - ANS -How many receptacle outlets are permitted .on a 20A. 120V ircuit in a commercial
building?
\18 feet - ANS -The minimum clearance for overhead feeder conductors not exceeding 600V
that pass over commercial areas Subject to truck traffic is.
\18" - ANS -At least one receptacle outlet shall be installed within of the top of a show window
for each 12 linear feet measured horizontally across its length
\18" - ANS -Receptacle outlets in floors shall not be counted as part of the required
number of receptacle outlets unless located within ______ of the wall
\180 VA - ANS -For other than dwelling occupancies, banks, or office buildings, each receptacle
outlet shall be calculated at
not less than _____ VA.
\1O ohms - ANS -The equivalent value of 0.1 mho is
\2 in of concrete - ANS -Conductors are considered outside a buildings when they are buried
under not less than
\20 amp - ANS -There shall be a minimum of one branch circuit for laundry outlets required by
210.52

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ALICE12 Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
128
Member since
2 year
Number of followers
16
Documents
2065
Last sold
1 week ago

Exams, Study guides, Reviews, Notes & Summaries All study solutions.

3.9

31 reviews

5
12
4
10
3
5
2
1
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions