Journeyman and Master Plumbing Exam Question Bank
well answered to pass
1. What degree is used for isometric drawings? 60 degrees
2. What is the recommended minimum of 20-30 minutes
minutes for chlorine water management?
3. When you need to repair a single handle O ring
lavatory faucet, what needs to be
replaced?
steel pipe is joined to
4. Galvanic corrosion of water supply piping can a dissimilar metal
occur where pipe
5. Whenever necessary to make an inspection to enforce at all
reasonable times
any of the provisions of the Code, an
authorized rep- resentative may enter the
premises
6. After completion of work and testing Supervisor of job
of sewer pipeline, who shall request at job-site
inspection?
Contractor
7. If the Administrative Authority requests
that a new type of material be used on a
project, who pays for the testing of the
new material?
8. When plumbing work is inspected and a "notice of cor- Within 10
days
rection" is served, how many days does the
contractor have to correct the work?
9. What is the vertical distance called that is between the Airgap,
drainage
, Journeyman and Master Plumbing Exam Question Bank
well answered to pass
lowest opening of a pipe fixture or
appurtenance that is discharging waste to the
overflow level of a fixture?
10. A cleanout which has direct access without the neces- readily
accessible
sity of removing any panel or door is defined to be
11. backflow
, Journeyman and Master Plumbing Exam Question Bank
well answered to pass
Distribution of water from any other source than
in- tended is
12. Back-siphonage is defined as the flowing back of
used, contaminated or
polluted water from a
plumbing fixture or
vessel into a wa- ter
supply pipe due to a
negative pressure in
such pipe
13. The is the pipe which building supply
carries potable water from a water meter to
a building.
14. Backflow is defined as non-potable water or
oth- er liquids
entering a potable
water system
15. Any group of two or more similar adjacent battery
fix-
tures that discharge into a common horizontal
waste branch is defined as a
Branch vent
16. Which of the following connects one or more
individ- ual vents to a vent stack?
horizontal
17. A combination waste and vent system may
be in- stalled on a piping
system.
18. The minimum level at which a vacuum breaker may be the critical
, Journeyman and Master Plumbing Exam Question Bank
well answered to pass
level
installed above the flood level rim of the device
and service is called
19. The "the critical level" is shown on a backflow preven- C-L or C/L
tion device by a marking.
well answered to pass
1. What degree is used for isometric drawings? 60 degrees
2. What is the recommended minimum of 20-30 minutes
minutes for chlorine water management?
3. When you need to repair a single handle O ring
lavatory faucet, what needs to be
replaced?
steel pipe is joined to
4. Galvanic corrosion of water supply piping can a dissimilar metal
occur where pipe
5. Whenever necessary to make an inspection to enforce at all
reasonable times
any of the provisions of the Code, an
authorized rep- resentative may enter the
premises
6. After completion of work and testing Supervisor of job
of sewer pipeline, who shall request at job-site
inspection?
Contractor
7. If the Administrative Authority requests
that a new type of material be used on a
project, who pays for the testing of the
new material?
8. When plumbing work is inspected and a "notice of cor- Within 10
days
rection" is served, how many days does the
contractor have to correct the work?
9. What is the vertical distance called that is between the Airgap,
drainage
, Journeyman and Master Plumbing Exam Question Bank
well answered to pass
lowest opening of a pipe fixture or
appurtenance that is discharging waste to the
overflow level of a fixture?
10. A cleanout which has direct access without the neces- readily
accessible
sity of removing any panel or door is defined to be
11. backflow
, Journeyman and Master Plumbing Exam Question Bank
well answered to pass
Distribution of water from any other source than
in- tended is
12. Back-siphonage is defined as the flowing back of
used, contaminated or
polluted water from a
plumbing fixture or
vessel into a wa- ter
supply pipe due to a
negative pressure in
such pipe
13. The is the pipe which building supply
carries potable water from a water meter to
a building.
14. Backflow is defined as non-potable water or
oth- er liquids
entering a potable
water system
15. Any group of two or more similar adjacent battery
fix-
tures that discharge into a common horizontal
waste branch is defined as a
Branch vent
16. Which of the following connects one or more
individ- ual vents to a vent stack?
horizontal
17. A combination waste and vent system may
be in- stalled on a piping
system.
18. The minimum level at which a vacuum breaker may be the critical
, Journeyman and Master Plumbing Exam Question Bank
well answered to pass
level
installed above the flood level rim of the device
and service is called
19. The "the critical level" is shown on a backflow preven- C-L or C/L
tion device by a marking.