Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 34 pages
Exam (elaborations)

Mosby CT Registry Review Questions With Complete Solutions

Document preview thumbnail
Preview 4 out of 34 pages

Mosby CT Registry Review Questions With Complete Solutions

Content preview

Mosby CT Registry Review Questions With
Complete Solutions
What is the smallest component of a digital image - VERIFIED ANSWER✔✔-pixel

How many CT numbers are assigned to each pixel in the image matrix? - VERIFIED ANSWER✔✔-One

In a CT image, the CT number - VERIFIED ANSWER✔✔-Of a material is dependent on its linear attenuation
coefficient

Each two-dimensional square of data that make up the CT image is called a - VERIFIED ANSWER✔✔-pixel

What is an element of the digital image - VERIFIED ANSWER✔✔-pixel

Which of the following influences the spatial resolution in cardiac CT imaging - VERIFIED ANSWER✔✔-
*detector size
*reconstruction interval
*pitch

As patient motion increases spatial resolution decreases - VERIFIED ANSWER✔✔-TRUE

Which is an advantage of using a small focal spot - VERIFIED ANSWER✔✔-increased spatial resolution

Increasing the CT image matrix from 256x256 to 512x512 will likely improve? - VERIFIED ANSWER✔✔-
High-contrast spatial resolution

The practical limiting spatial resolution of a CT scanner is 3.6 lp/cm. What size object does this correspond to? -
VERIFIED ANSWER✔✔-1.4 mm

Use of a bone filter, as opposed to a soft tissue filter, to reconstruct CT images would likely improve? -
VERIFIED ANSWER✔✔-Spatial resolution

The spatial resolution of a typical CT scanner is on the order of? - VERIFIED ANSWER✔✔-1 mm

A 512 x 512 matrix CT image over a 30-cm field of view could show a spatial resolution of no better than ?
lp/cm? - VERIFIED ANSWER✔✔-8.5

When comparing a 512x512 matrix to a 1024x1024 matrix, the 1024x1024 matrix? - VERIFIED ANSWER✔✔-
Contains four times as many pixels: 1024 x 1024 =1048576 then 512 x 512= 262144...then divide 1048576
/262144 = 4

High contrast spatial resolution and low contrast resolution are typically measured baseline and ? thereafter -
VERIFIED ANSWER✔✔-Biannually

To improve the high contrast spatial resolution of a CT study, one would increase _____ while keeping all other
factors the same. - VERIFIED ANSWER✔✔-Matrix size (128x128 to 512x512)

A radiologist wants to improve the high-contrast spatial resolution of anatomy which he/she is examining by CT.
The change which would best lead to this improvement is - VERIFIED ANSWER✔✔-Increase the matrix size

To improve the high-contrast spatial resolution of a CT study, one could increase ? while keeping all other factors
the same? - VERIFIED ANSWER✔✔-Matrix size

A voxel contains 25% air, 50% water and 25% bone. The CT number for this voxel would be expected to be
_____ HU? - VERIFIED ANSWER✔✔-0

,How many pixels are contained in a 1,024 matrix image? - VERIFIED ANSWER✔✔-D. 1,048,576

MATH 1024 X1024

It is located in a matrix and is a two dimensional representation of a voxel - VERIFIED ANSWER✔✔-pixel

When CT numbers are calculated for voxels (volume elements) of tissue what is assigned the calculated number
and a subsequent shade of gray - VERIFIED ANSWER✔✔-pixel

What is defined as a picture element or the smallest component of the digital image - VERIFIED ANSWER✔✔-
pixel

A CT scan produces a 512x512 matrix transverse image of a 30 cm diameter FOV. Each pixel is approximately
_____ mm on a side. - VERIFIED ANSWER✔✔-0.6 equation: 30cm/512= .058cm convert to mm and its .58
which is approximately 0.6

The ability of a system to define small objects distinctly is referred to as which of the following? - VERIFIED
ANSWER✔✔-spatial resolution

Which of the following terms is/are commonly used to describe a CT scanner's ability to differentiate objects with
similar linear attenuation coeffiecents - VERIFIED ANSWER✔✔-*spatial resolution
*sensitivity

Which of the following factors have an affect on contrast resolution - VERIFIED ANSWER✔✔-*patient size
*slice thickness
*pixel size
*mAs/dose

As mAs/dose increases contrast resolution decreases - VERIFIED ANSWER✔✔-FALSE

As mAs/dose increases contrast resolution INCREASES - VERIFIED ANSWER✔✔-TRUE

The ability of a CT scanner to accurately image objects with similar densities is termed - VERIFIED
ANSWER✔✔-*contrast resolution
*sensitivity

Which of the following has a direct relationship on increasing contrast resolution - VERIFIED ANSWER✔✔-
*mAs/dose increase
*Slice thickness

For a particular CT scanner's beam quality, the linear attenuation coefficient for water is 0.20 cm-1 and for a
certain tumor is 0.21 cm-1. What is the CT number of the tumor? - VERIFIED ANSWER✔✔-50. Equation
(.21-.20/.21) × 1000= 50

A CT scanner with poor contrast resolution or low sensitivity has difficulty separating - VERIFIED
ANSWER✔✔-tissues whose linear attenuation coefficients are nearly equal

What is the basic physical quantity being measured by a CT system - VERIFIED ANSWER✔✔-Linear
attenuation coefficient

Assume the linear attenuation coefficient is 0.20 cm-1 for water and 0.40 cm-1 for tissue within a given voxel.
What is the CT number in Hounsfield units for the pixel representing this voxel? - VERIFIED ANSWER✔✔-
+1,000....Equation { (.4-.2) /.2} x 1000

What fraction of monoenergetic x-rays will be absorbed by a 20-cm thick material having a linear attenuation
coefficient of 0.05 cm-1? - VERIFIED ANSWER✔✔-0.63

The contrast resolution of CT is approximately ? % - VERIFIED ANSWER✔✔-0.3 to 0.6

,This term describes the ability CT scanner to differentiate objects with MINIMAL differences in attenuation
coefficients - VERIFIED ANSWER✔✔-contrast resolution

What is the term for resolution of a CT scanner referred to as the system's ability to differentiate objects with
SIMILAR densities. - VERIFIED ANSWER✔✔-contrast resolution

In order to pass ACR CT accreditation, the CT scanner's adult head protocol must be within - VERIFIED
ANSWER✔✔-1.0

The QC test for the average CT number for water should be done - VERIFIED ANSWER✔✔-Daily

The following are all basic tenets of a QC program for computed tomography scanner - VERIFIED
ANSWER✔✔-*QC test must be conducted regularly
*Accurate record keeping
*all test results must be interpreted promptly

Using the ACR CT accreditation phantom, module 3 is used to measure which of the following - VERIFIED
ANSWER✔✔-CT number uniformity

The following QC test should be done on a monthly basis - VERIFIED ANSWER✔✔-high contrast resolution

The CT number at the center of a uniformly filled water phantom should ideally be - VERIFIED ANSWER✔✔-0

The ACR CT accreditation phantom is designed to perform QC measurements of - VERIFIED ANSWER✔✔-
*positioning accuracy and light accuracy alignment only
*CT number accuracy and slice thickness only
*low contrast resolution, CT number uniformity, and high contrast resolution

The ACR tolerance limit for the CT number accuracy for water is - VERIFIED ANSWER✔✔-+-7HU or +-5
preferred

The test for the average CT number of water should be tested at - VERIFIED ANSWER✔✔-*acceptance
*daily

The ACR tolerance limit for the CT number uniformity is which of the following - VERIFIED ANSWER✔✔-
The center CT number must be between plus or minus 7HU plus the abdomen protocol must be used

To evaluate low contrast resolution, phantoms are scanned using different ? settings - VERIFIED ANSWER✔✔-
mAs

For an increase from 200 mA to 400 mA in a CT exam, the result would be to - VERIFIED ANSWER✔✔-
Increase low contrast resolution

This ability is also commonly referred to as the low contrast resolution or the sensitivity of the CT scanner -
VERIFIED ANSWER✔✔-contrast resolution

The major advantage of a CT scanner over a screen-film radiography system is - VERIFIED ANSWER✔✔-
Better low contrast discrimination

For CT images, all of the following factors improve the visibility of large, low-contrast lesions except? -
VERIFIED ANSWER✔✔-Smaller pixel sizes

As the iodine concentration ? the viscosity of the substance will ? - VERIFIED ANSWER✔✔-increase, increase

A fluid with a high viscosity is relatively - VERIFIED ANSWER✔✔-thick and flows slowly

The viscosity of a solution may be changed by regulating - VERIFIED ANSWER✔✔-temperature

A patient with a temperature over ______ is considered to have a fever.

, 98.6.
96.8.
99.8.
100. - VERIFIED ANSWER✔✔-Correct Answer:
99.8



www.examedge.com

The body temperature fluctuates, and the normal range is between - VERIFIED ANSWER✔✔-96.8 and 99.8.


www.examedge.com

A patient has a fever once the temperature rises above ?. Temperatures are likely to be higher as it grows later. -
VERIFIED ANSWER✔✔-99.8

www.examedge.com

Which of these describes a liver window setting?


Approximate width of 275 and window level 90.
Approximate width of 150 and window level 70.
Approximate width of 305 and window level 50.
Approximate width of 80 and window level 90. - VERIFIED ANSWER✔✔-Approximate width of 150 and
window level 70.


www.examedge.com

The use of the liver window makes it easier to view subtle - VERIFIED ANSWER✔✔-liver lesions

www.examedge.com

Although it may be a bit more difficult to see subtle liver lesions, a ? can also be used. - VERIFIED
ANSWER✔✔-routine soft-tissue window setting

www.examedge.com

Contrast enhancement phases of the liver include which of the following - VERIFIED ANSWER✔✔-*arterial
*portal venous
*equilibrium phase
*early arterial
*delayed phases

Malignant neoplasms of the liver include which of the following - VERIFIED ANSWER✔✔-*hepatocellular
carcinoma HCC

Malignant neoplasms of the liver include which of the following - VERIFIED ANSWER✔✔-*hepatocellular
carcinoma HCC

What is the most common malignant neoplasms of the liver - VERIFIED ANSWER✔✔-hepatocellular carcinoma
HCC and metastases

IMAGE IS metastases

Hemanglomas and focal nodular hyperplasia FNH are both examples of what types of tumors - VERIFIED

Document information

Uploaded on
January 27, 2025
Number of pages
34
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Lectphilip
4.0
(42)
Sold
288
Followers
7
Items
26613
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions