Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 1 out of 4 pages
Exam (elaborations)

PRM 2025 EXAM QUESTIONS AND ANSWERS ALL CORRECT

Document preview thumbnail
Preview 1 out of 4 pages

PRM 2025 EXAM QUESTIONS AND ANSWERS ALL CORRECT What kind of detectors are Off Gas Post-Treatment Rad Monitors? Where are samples pulled from? - Answer-• detector is a gamma sensitive scintillation detector • Samples downstream of the OG System charcoal adsorber beds. What kind of detectors do Carbon Bed Vault Radiation Monitoring System use? - Answer-a gamma sensitive Geiger Mueller tube Integral Sr-90 source ("bug" source) provides on-scale reading at background radiation level. Indicator and Trip Unit - Answer-consists of an amplifier, two trip units and a meter in a drawer on the H13-P635 back panel. HIGH Rad actuates the upscale trip unit (red light) on the instrument drawer and actuates alarms on N62-P600 and locally (the Auxiliary Trip Unit located outside the Carbon Bed Vault in the OG Filter Building actuates a klaxon horn and warning lights). What kind of detectors do VR Exhaust Plenum Rad Monitors use? - Answer-• a gamma sensitive Geiger Mueller tube • Detectors are located upstream of VR exhaust isolation dampers AB 786' What are the VR exhaust plenum rad detector divisions? - Answer-• 'A' and 'B' meters (Div 1, outboard) • 'C' and 'D' meters (Div 2, inboard) What happens on a VR HI HI Rad (8 mR/hr)? - Answer-Div 1 (A and B) or Div 2 (C and D) High-High rad initiates Group 4 PCIS. For clarity, if only Div 1 (A & B) monitors initiate, ONLY the outboard damper will close. What kind of detectors do Fuel Pool Vent Exhaust Plenum Rad Monitors use? Where are they located? - Answer-• a gamma sensitive Geiger Mueller tube located 820 RB by SBLC What are the FC exhaust plenum rad detector divisions? - Answer-• 'A' and 'B' meters (Div 1, outboard) • 'C' and 'D' meters (Div 2, inboard) Div 1 (A and B) or Div 2 (C and D) High-High rad initiates Group 4 PCIS. What kind of detectors do Liquid Process Radiation Monitoring (PRM) System use? - Answer-gamma sensitive scintillation detectors Where do we use Liquid PRMs? - Answer-WS (AB 692') WR (RB 761') RHR WS 'A' HX effluent (RB NW 710') RHR WS 'B' HX effluent (RB SE 710') Radwaste Effluent (AB 692') What kind of detectors do Radwaste Effluent Monitoring System use? - Answer-• gamma sensitive scintillation detectors • Obtains samples from the Discharge Piping between the isolation valve (0WL067) and the Lake Blowdown line piping. What signals closes the Lake Blowdown Radwaste Discharge FCV (0WL067) and trips the Radwaste Discharge Pumps 0(1)2WF05P? - Answer-• Low sample flow ( 3 gpm) • High-High rad • INOP trip What kind of detectors do VC HVAC Air Intake Monitors use? - Answer-4 GM tube detectors for each VC system air intake plenum • A and B detectors input to Trip System 1 • C and D detectors input to Trip System 2 What happens on an Upscale trip (6 mr/hr) on both VC detectors in either Trip System? - Answer-• Closes VC normal intake (minimum outside) air dampers • VE/VC purge supply and exhaust dampers are interlocked closed • Aligns VC EMU: fan starts and EMU inlet/outlet dampers open What is the purpose of the Station Ventilation Stack Rad Monitors (SVS WRGM)? What type of detectors does it use? - Answer-• beta scintillation detectors • Continuously monitors, indicates, and records Noble Gas releases from the Station • Provides means to sample/analyze for Particulates, Iodine, and Noble Gas • Initiates an alarm of GSEP conditions based on the release rates • Provides isokinetic sampling (with auto flow control) for representative particulate and iodine sampling What does Isokinetic mean? - Answer-means air velocity entering the sampling nozzle equals the air velocity in the stack at that point What is Nominal sample flow through the probe? - Answer-Nominal sample flow through the probe of 2.0 scfm is based on a 1 x 106 scfm stack gas flow rate N62-P600-B304 "STA VENT STACK WIDE RANGE RAD HI" alarm setpoints: - Answer-• 2 x 104 μci/sec: Yellow ALERT on SVS WRGM RM-23 for effluent channel lights up • 6. 1 x 105 μci/sec: Red HI-HI light on SVS WRGM RM-23 for effluent channel lights up When will the low range detector not operate? - Answer-The low range detector will not operate while using the grab sample mode.

Content preview

PRM 2025 EXAM QUESTIONS AND
ANSWERS ALL CORRECT

What kind of detectors are Off Gas Post-Treatment Rad Monitors? Where are samples
pulled from? - Answer-• detector is a gamma sensitive scintillation detector
• Samples downstream of the OG System charcoal adsorber beds.

What kind of detectors do Carbon Bed Vault Radiation Monitoring System use? -
Answer-a gamma sensitive Geiger Mueller tube

Integral Sr-90 source ("bug" source) provides on-scale reading at background radiation
level.

Indicator and Trip Unit - Answer-consists of an amplifier, two trip units and a meter in a
drawer on the H13-P635 back panel. HIGH Rad actuates the upscale trip unit (red light)
on the instrument drawer and actuates alarms on N62-P600 and locally (the Auxiliary
Trip Unit located outside the Carbon Bed Vault in the OG Filter Building actuates a
klaxon horn and warning lights).

What kind of detectors do VR Exhaust Plenum Rad Monitors use? - Answer-• a gamma
sensitive Geiger Mueller tube

• Detectors are located upstream of VR exhaust isolation dampers AB 786'

What are the VR exhaust plenum rad detector divisions? - Answer-• 'A' and 'B' meters
(Div 1, outboard)
• 'C' and 'D' meters (Div 2, inboard)

What happens on a VR HI HI Rad (8 mR/hr)? - Answer-Div 1 (A and B) or Div 2 (C and
D) High-High rad initiates Group 4 PCIS. For clarity, if only Div 1 (A & B) monitors
initiate, ONLY the outboard damper will close.

What kind of detectors do Fuel Pool Vent Exhaust Plenum Rad Monitors use? Where
are they located? - Answer-• a gamma sensitive Geiger Mueller tube located 820 RB by
SBLC

What are the FC exhaust plenum rad detector divisions? - Answer-• 'A' and 'B' meters
(Div 1, outboard)

Document information

Uploaded on
January 25, 2025
Number of pages
4
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Scholarsstudyguide
3.8
(169)
Sold
840
Followers
475
Items
16331
Last sold
3 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions