S13 standpipe test Questions Complete Solutions Automatic Standpipe System - Answer-A standpipe system that is attached to a water supply capable of supplying the system demand at all times and that requires no action other than opening a hose valve to provide water at hose connections. /.Auxiliary water supply - Answer-supplementary source of water for a standpipe and/or sprinkler system. /.Control Valve - Answer-A valve controlling flow to water-based fire protection systems. Control valves do not include hose valves, inspector's test valves, drain valves, trim valves for dry pipe, pre-action and deluge valves, check valves, or relief valves. /.Branch line - Answer-A pipe system, generally in a horizontal plane, connecting not more than one hose connection with a standpipe. /.Deficiency - Answer-A condition in which the application of the component is not within its designed limits or specifications. /.Fire Hose Outlet and Release Rack - Answer-A water supply control valve intended to be operated by actuation of an automatic detection system that is installed in the same area as the discharge devices. Each deluge valve is intended to be capable of automatic and manual operation. Deluge systems are suitable for hazardous occupancies. This includes buildings in which flammable liquids or other hazardous materials are handled or stored. /.Discharge Device - Answer-A device designed to discharge water or foam-water solution in a predetermined, fixed, or adjustable pattern. Examples include, but are not limited to, sprinklers, spray nozzles, and hose nozzles. /.Dry Standpipe - Answer-A standpipe system designed to have piping contain water only when the system is being utilized (No automatic water supply.) /.Dunnage - Answer-Rooftop dunnage involves designing a raised series of beams (usually steel) bearing on posts or bearing walls to support mechanical equipment (usually on a roof top). /.Fire Department Connection - Answer-A connection , normally on the exterior of the building, through which the fire department can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. (Formerly know as Siamese connection.) /.Fire Hose - Answer-A flexible conduit constructed with one or more reinforcements (Jackets), with or without a coating or covering but with an approved nonpermeable lining, or with an inner reinforcement between a protective cover and an approved nonpermeable lining. /.Fire Hydrant - Answer-A valve connection on a water supply system having one or more outlets and that is used to supply hose and fire department pumps with water. /.Fire Pump - Answer-A pump that is a provider of liquid flow and pressure dedicated to fire protection. A fire pump is a part of a fire standpipe system's water supply and can be powered by electric, diesel or steam. The pump intake is either connected to the public underground water supply piping or a static water source (e.g., tank, reservoir, lake). The pump provides water flow at higher pressure and volume to the standpipe system risers and hose standpipes. /.Fold - Answer-A transverse bend (fold) occurring where the hose is lengthwise double over on itself, as on a pin rack. /.Gallons per minute (GPM) - Answer-typically used to measure fluid flow rate (such as water) or pump capacity. Measurement of water flow rate for a pump or a fire standpipe or sprinkler system. /.Hose Connection - Answer-a combination of equipment provided for connection of a hose to the standpipe system that includes a hose valve with a threaded outlet. /.Attack Hose - Answer-Hose designed to be used by trained fire fighters and fire brigade members to combat fires beyond the incipient stage. /.Booster Hose - Answer-A non-collapsible hose used under positive pressure having an elastomeric or thermoplastic tube, a braided or spiraled reinforcement, and an outer protective cover. /.Covered Hose - Answer-A hose with a jacket covered and lined with a continuous synthetic rubber or plastic. The cover is usually thicker than a coating. /.Fire Hose - Answer-A flexible conduit used to convey water. /.Hose Valve - Answer-The valve to an individual hose connection /.Occupant Use Hose - Answer-Fire hose designed to be used by the building's occupants to fight incipient fires prior to the arrival of trained fire fighters or fire brigade members. /.Unlined Hose - Answer-A hose consisting of only a woven jacket that is usually of linen yarns and is of such quality that the yarn swells when wet, tending to seal the hose.

Show more Read less
Institution
S13 Standpipe
Course
S13 standpipe









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
S13 standpipe
Course
S13 standpipe

Document information

Uploaded on
January 19, 2025
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • s13 standpipe test

Content preview

S13 standpipe test Questions Complete Solutions

Automatic Standpipe System - Answer-A standpipe system that is attached to a water
supply capable of supplying the system demand at all times and that requires no action
other than opening a hose valve to provide water at hose connections.

/.Auxiliary water supply - Answer-supplementary source of water for a standpipe and/or
sprinkler system.

/.Control Valve - Answer-A valve controlling flow to water-based fire protection systems.
Control valves do not include hose valves, inspector's test valves, drain valves, trim
valves for dry pipe, pre-action and deluge valves, check valves, or relief valves.

/.Branch line - Answer-A pipe system, generally in a horizontal plane, connecting not
more than
one hose connection with a standpipe.

/.Deficiency - Answer-A condition in which the application of the component is not within
its designed limits or specifications.

/.Fire Hose Outlet and Release Rack - Answer-A water supply control valve intended to
be operated by actuation of an automatic detection system that is installed in the same
area as the discharge devices. Each deluge valve is intended to be capable of
automatic and manual operation. Deluge systems are suitable for hazardous
occupancies. This includes buildings in which flammable liquids or other hazardous
materials are handled or stored.

/.Discharge Device - Answer-A device designed to discharge water or foam-water
solution in a predetermined, fixed, or adjustable pattern. Examples include, but are not
limited to, sprinklers, spray nozzles, and hose nozzles.

/.Dry Standpipe - Answer-A standpipe system designed to have piping contain water
only when the system is being utilized (No automatic water supply.)

/.Dunnage - Answer-Rooftop dunnage involves designing a raised series of beams
(usually steel) bearing on posts or bearing walls to support mechanical equipment
(usually on a roof
top).

/.Fire Department Connection - Answer-A connection , normally on the exterior of the
building, through which the fire department can pump supplemental water into the
sprinkler system, standpipe, or other system furnishing water for fire extinguishment to
supplement existing water supplies. (Formerly know as Siamese connection.)

, /.Fire Hose - Answer-A flexible conduit constructed with one or more reinforcements
(Jackets), with or without a coating or covering but with an approved nonpermeable
lining, or with an inner reinforcement between a protective cover and an approved
nonpermeable lining.

/.Fire Hydrant - Answer-A valve connection on a water supply system having one or
more outlets and that is used to supply hose and fire department pumps with water.

/.Fire Pump - Answer-A pump that is a provider of liquid flow and pressure dedicated to
fire protection. A fire pump is a part of a fire standpipe system's water supply and can
be powered by electric, diesel or steam. The pump intake is either connected to the
public underground water supply piping or a static water source (e.g., tank, reservoir,
lake). The pump provides water flow at higher pressure and volume to the standpipe
system risers and hose standpipes.

/.Fold - Answer-A transverse bend (fold) occurring where the hose is lengthwise double
over on itself, as on a pin rack.

/.Gallons per minute (GPM) - Answer-typically used to measure fluid flow rate (such as
water) or pump capacity. Measurement of water flow rate for a pump or a fire standpipe
or sprinkler system.

/.Hose Connection - Answer-a combination of equipment provided for connection of a
hose to the standpipe system that includes a hose valve with a threaded outlet.

/.Attack Hose - Answer-Hose designed to be used by trained fire fighters and fire
brigade members to combat fires beyond the incipient stage.

/.Booster Hose - Answer-A non-collapsible hose used under positive pressure having an
elastomeric or thermoplastic tube, a braided or spiraled reinforcement, and an outer
protective cover.

/.Covered Hose - Answer-A hose with a jacket covered and lined with a continuous
synthetic rubber or plastic. The cover is usually thicker than a coating.

/.Fire Hose - Answer-A flexible conduit used to convey water.

/.Hose Valve - Answer-The valve to an individual hose connection

/.Occupant Use Hose - Answer-Fire hose designed to be used by the building's
occupants to fight incipient fires prior to the arrival of trained fire fighters or fire brigade
members.

/.Unlined Hose - Answer-A hose consisting of only a woven jacket that is usually of linen
yarns and is of such quality that the yarn swells when wet, tending to seal the hose.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
kartelodoc Harvard University
View profile
Follow You need to be logged in order to follow users or courses
Sold
119
Member since
1 year
Number of followers
4
Documents
8168
Last sold
1 week ago

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. I WISH YOU SUCCESS IN YOUR EDUCATION JOURNEY

Read more Read less
3.2

22 reviews

5
7
4
1
3
7
2
3
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions