UST QUESTIONS TO STUDY
The00regulations00to00enforce00compliance00of00underground00storage00tank00systems00i
n00the00state00are00found00in?
a.)00Code00of00Federal00Regulations,004000CFR00Part00281
b.)00California00Code00of00Regulations,00Title0023,00Chapter0016
c.)00Code00of00Federal00Regulations,004000CFR00Part00280
d.)00California00Code00of00Regulations,00Title0023,00Chapter001700-00ans--
✔✔b.)00California00Code00of00Regulations;00Title0023,00Chapter0016
By00definition00an00"underground00storage00tank00system"00includes
a.)00The00tank,00all00connected00piping00and00dispensers
b.)00The00tank,00all00connected00piping,00ancillary00equipment00and00containment00syste
m
c.)00Only00the00tank
d.)00Only00tanks00totally00beneath00the00surface00of00the00ground00-00ans--
✔✔b.)00The00tank,00all00connected00piping,00ancillary00equipment00and00containment00s
ystem
(H&SC,00Sec0025281(z))
Under-
dispenser00containment00was00required00for00all00UST00systems00by00___________.
a.)00December0031,002003
b.)00July001,001987
c.)00January001,001984
d.)00January001,00200000-00ans--✔✔a.)00December0031,002003
CCR00Title0023,00Sec002636(g)(C)
According00to00California00Law,00UST00systems00installed00after00July001,002003,00requir
e00a00one-time00ELD00test00to00ensure00that00the00tank00is00product00tight...
a.)00If00the00tank00is00located00within00one00(1)00mile00of00a00public00drinking00water00wel
l
b.)00If00the00tank00is00located00within00100000feet00of00a00public00drinking00water00well
,c.)00Unless00the00tank00is00equipped00with00secondary00containment
d.)00In00all00cases00-00ans--✔✔For00ALL00tanks00before00use00(H&SC0025290.200(I))
d.)00In00all00cases
H&SC,00Sec0025290.2(i)
The00written00report00submitted00to00the00local00agency00after00an00unauthorized00releas
e00is00required00to00include00the00following00except:
a.)00Description00of00actions00taken00to00stop00the00release
b.)00Cause00of00the00release
c.)00Method00of00disposal00of00released00product
d.)00Date00on00which00the00release00was00discovered00-00ans--
✔✔b.)00Cause00of00the00release
CCR00Title0023,00Sec002652(c)
An00unauthorized00release00which00does00not00escape00from00secondary00containment0
0only00requires00a00record00on00the00operator's00monitoring00reports00provided:00
A.00It00did00not00increase00the00hazard00of00fire00
B.00It00did00not00cause00any00deterioration00of00the00secondary00containment00
C.00It00was00cleaned00up00within00800hours00of00detection
D.00All00of00the00above00-00ans--✔✔D.00All00of00the00above00
H&SC,00Sec0025294
The00annual00monitoring00certification00may00be00performed00by:
A.00A00person00possessing00the00appropriate00contractors00licenses
B.00An00individual00trained00and00certified00by00the00manufacturer00of00the00monitoring00
equipment
C.00A00designated00UST00operator
D.00A00person00who00meets00the00requirements00of00both00a00and00b00-00ans--
✔✔D.00A00person00who00meets00the00requirements00of00both00a00and00b
CCR00Title0023,00Sec002715(i)
The00following00is00true00of00secondary00containment00testing,00EXCEPT:
a.)00Must00be00tested00every002400months
b.)00Must00be00tested00every003600months
c.)00Results00must00be00submitted00to00the00local00agency00within003000days00of00testing
d.)00Local00agency00must00be00notified004800hours00prior00to00testing00-00ans--
✔✔a.)00Must00be00tested00every002400months
,CCR00Title0023,00Sec002637(a)
Records00of00cathodic00protection00system00maintenance00must00be00kept00on00file00for0
0______________.
a.)001000years
b.)001.500years
c.)00300years
d.)006.500years00-00ans--✔✔d.)006.500years
CCR00Title0023,00Sec002712(b)
Impressed00current00cathodic00protection00systems00shall00be00inspected00no00less00tha
n00every00___________00to00ensure00that00they00are00in00proper00working00order:
a.)006000days
b.)009000days
c.)003000days
d.)0012000days00-00ans--✔✔a.)006000days
CCR00Title0023,00Sec002635(a)(2)
Monthly00monitoring00data00must00be00kept00on00file00for00_________________.
a.)00300years
b.)006.500years
c.)00500years
d.)00For00the00life00of00the00UST00system00-00ans--✔✔a.)00300years
CCR00Title0023,00Sec002712(b)
By00December0022,001998,00all00automatic00line00leak00detectors00installed00on00single-
walled00pressurized00piping00must00be00capable00of:
a.)00Restricting00product00flow
b.)00Triggering00an00audible00and00visual00alarm
c.)00Shutting00down00the00pumping00system
d.)00Shutting00off00the00flow00at00the00dispenser00-00ans--
✔✔c.)00Shutting00down00the00pumping00system
CCR00Title0023,00Sec002666(c)
When00an00automatic00tank00gauge00is00utilized00for00single-
walled00tank00leak00detection,00it00shall00generate00a00post-
test00hard00copy00data00report00of00the00following00information,00except:
, a.)00Liquid00volume
b.)00Fuel00depth
c.)00Outside00air00temperature
d.)00Time00and00date00of00test00-00ans--✔✔c.)00Outside00air00temperature
CCR00Title0023,00Sec002643(b)(1)
If00a00UST00system00is00utilizing00an00overfill00alarm,00the00alarm00must00be00triggered00t
o00alert00the00transfer00operator00when00the00tank00is00no00more00than00___________00f
ull
a.)0085%
b.)0095%
c.)0090%
d.)0080%00-00ans--✔✔c.)0090%
CCR00Title0023,00Sec002635(b)(2)(A)
A00service00technician00has00performed00calibration00and00maintenance00on00an00ATG00
probe;00this00maintenance00record00must00be00kept00on00file00for00______________.
a.)006.500years
b.)00300years
c.)00500years
d.)00Life00of00the00UST00system00-00ans--✔✔c.)00500years
CCR00Title0023,00Sec002712(b)
An00automatic00tank00gauge00is00utilized00for00leak00detection00of00the00_____________
_.
a.)00Tank
b.)00Tank00and00Piping
c.)00Piping
d.)00Interstitial00space00-00ans--✔✔a.)00Tank
CCR00Title0023,00Sec002643(b)(1)
After00completion00of00enhanced00leak00detection00(ELD)00test,00the00ELD00test00results0
0must00be00submitted00to00the00_________________.
a.)00The00local00agency
b.)00The00SWRCB00
c.)00Owner00of00the00UST00system
d.)00To00both00the00SWRCB00and00the00local00agency00-00ans--
✔✔d.)00To00both00the00SWRCB00and00the00local00agency
The00regulations00to00enforce00compliance00of00underground00storage00tank00systems00i
n00the00state00are00found00in?
a.)00Code00of00Federal00Regulations,004000CFR00Part00281
b.)00California00Code00of00Regulations,00Title0023,00Chapter0016
c.)00Code00of00Federal00Regulations,004000CFR00Part00280
d.)00California00Code00of00Regulations,00Title0023,00Chapter001700-00ans--
✔✔b.)00California00Code00of00Regulations;00Title0023,00Chapter0016
By00definition00an00"underground00storage00tank00system"00includes
a.)00The00tank,00all00connected00piping00and00dispensers
b.)00The00tank,00all00connected00piping,00ancillary00equipment00and00containment00syste
m
c.)00Only00the00tank
d.)00Only00tanks00totally00beneath00the00surface00of00the00ground00-00ans--
✔✔b.)00The00tank,00all00connected00piping,00ancillary00equipment00and00containment00s
ystem
(H&SC,00Sec0025281(z))
Under-
dispenser00containment00was00required00for00all00UST00systems00by00___________.
a.)00December0031,002003
b.)00July001,001987
c.)00January001,001984
d.)00January001,00200000-00ans--✔✔a.)00December0031,002003
CCR00Title0023,00Sec002636(g)(C)
According00to00California00Law,00UST00systems00installed00after00July001,002003,00requir
e00a00one-time00ELD00test00to00ensure00that00the00tank00is00product00tight...
a.)00If00the00tank00is00located00within00one00(1)00mile00of00a00public00drinking00water00wel
l
b.)00If00the00tank00is00located00within00100000feet00of00a00public00drinking00water00well
,c.)00Unless00the00tank00is00equipped00with00secondary00containment
d.)00In00all00cases00-00ans--✔✔For00ALL00tanks00before00use00(H&SC0025290.200(I))
d.)00In00all00cases
H&SC,00Sec0025290.2(i)
The00written00report00submitted00to00the00local00agency00after00an00unauthorized00releas
e00is00required00to00include00the00following00except:
a.)00Description00of00actions00taken00to00stop00the00release
b.)00Cause00of00the00release
c.)00Method00of00disposal00of00released00product
d.)00Date00on00which00the00release00was00discovered00-00ans--
✔✔b.)00Cause00of00the00release
CCR00Title0023,00Sec002652(c)
An00unauthorized00release00which00does00not00escape00from00secondary00containment0
0only00requires00a00record00on00the00operator's00monitoring00reports00provided:00
A.00It00did00not00increase00the00hazard00of00fire00
B.00It00did00not00cause00any00deterioration00of00the00secondary00containment00
C.00It00was00cleaned00up00within00800hours00of00detection
D.00All00of00the00above00-00ans--✔✔D.00All00of00the00above00
H&SC,00Sec0025294
The00annual00monitoring00certification00may00be00performed00by:
A.00A00person00possessing00the00appropriate00contractors00licenses
B.00An00individual00trained00and00certified00by00the00manufacturer00of00the00monitoring00
equipment
C.00A00designated00UST00operator
D.00A00person00who00meets00the00requirements00of00both00a00and00b00-00ans--
✔✔D.00A00person00who00meets00the00requirements00of00both00a00and00b
CCR00Title0023,00Sec002715(i)
The00following00is00true00of00secondary00containment00testing,00EXCEPT:
a.)00Must00be00tested00every002400months
b.)00Must00be00tested00every003600months
c.)00Results00must00be00submitted00to00the00local00agency00within003000days00of00testing
d.)00Local00agency00must00be00notified004800hours00prior00to00testing00-00ans--
✔✔a.)00Must00be00tested00every002400months
,CCR00Title0023,00Sec002637(a)
Records00of00cathodic00protection00system00maintenance00must00be00kept00on00file00for0
0______________.
a.)001000years
b.)001.500years
c.)00300years
d.)006.500years00-00ans--✔✔d.)006.500years
CCR00Title0023,00Sec002712(b)
Impressed00current00cathodic00protection00systems00shall00be00inspected00no00less00tha
n00every00___________00to00ensure00that00they00are00in00proper00working00order:
a.)006000days
b.)009000days
c.)003000days
d.)0012000days00-00ans--✔✔a.)006000days
CCR00Title0023,00Sec002635(a)(2)
Monthly00monitoring00data00must00be00kept00on00file00for00_________________.
a.)00300years
b.)006.500years
c.)00500years
d.)00For00the00life00of00the00UST00system00-00ans--✔✔a.)00300years
CCR00Title0023,00Sec002712(b)
By00December0022,001998,00all00automatic00line00leak00detectors00installed00on00single-
walled00pressurized00piping00must00be00capable00of:
a.)00Restricting00product00flow
b.)00Triggering00an00audible00and00visual00alarm
c.)00Shutting00down00the00pumping00system
d.)00Shutting00off00the00flow00at00the00dispenser00-00ans--
✔✔c.)00Shutting00down00the00pumping00system
CCR00Title0023,00Sec002666(c)
When00an00automatic00tank00gauge00is00utilized00for00single-
walled00tank00leak00detection,00it00shall00generate00a00post-
test00hard00copy00data00report00of00the00following00information,00except:
, a.)00Liquid00volume
b.)00Fuel00depth
c.)00Outside00air00temperature
d.)00Time00and00date00of00test00-00ans--✔✔c.)00Outside00air00temperature
CCR00Title0023,00Sec002643(b)(1)
If00a00UST00system00is00utilizing00an00overfill00alarm,00the00alarm00must00be00triggered00t
o00alert00the00transfer00operator00when00the00tank00is00no00more00than00___________00f
ull
a.)0085%
b.)0095%
c.)0090%
d.)0080%00-00ans--✔✔c.)0090%
CCR00Title0023,00Sec002635(b)(2)(A)
A00service00technician00has00performed00calibration00and00maintenance00on00an00ATG00
probe;00this00maintenance00record00must00be00kept00on00file00for00______________.
a.)006.500years
b.)00300years
c.)00500years
d.)00Life00of00the00UST00system00-00ans--✔✔c.)00500years
CCR00Title0023,00Sec002712(b)
An00automatic00tank00gauge00is00utilized00for00leak00detection00of00the00_____________
_.
a.)00Tank
b.)00Tank00and00Piping
c.)00Piping
d.)00Interstitial00space00-00ans--✔✔a.)00Tank
CCR00Title0023,00Sec002643(b)(1)
After00completion00of00enhanced00leak00detection00(ELD)00test,00the00ELD00test00results0
0must00be00submitted00to00the00_________________.
a.)00The00local00agency
b.)00The00SWRCB00
c.)00Owner00of00the00UST00system
d.)00To00both00the00SWRCB00and00the00local00agency00-00ans--
✔✔d.)00To00both00the00SWRCB00and00the00local00agency