Automatic Standpipe System - ANS A standpipe system that is attached to a water supply capable of supplying the system demand at all times and that requires no action other than opening a hose valve to provide water at hose connections. Churning - ANS A condition in a centrifugal in which the impeller is rotating, but no water is being discharged. Combination Standpipe and Sprinkler System - ANS A system where the water piping service both 2 1/2in (65) outlet for fire Department use and oulet for automatic sprinkler Concealed Sprinkler - ANS A recessed sprinkler with a cover plate Deluge Valve - ANS water supply control valve intended to be operated by actuation of an automatic detection system that is installed in the same area as the discharge devices. Suitable for HAZARDOUS OCCUPANCIES. INTENDED USE IS MANUAL AND AUTO Deludge Sprinkler System - ANS A sprinkler system employing open sprinklers that are attached to a piping system that is connected to a water supply through a VALVE that is opened of a DETECTION SYSTEM installed in the same area as the sprinklers Dry Pipe Sprinkler System - ANS A sprinkler system employing automatic sprinklers that are attached to a piping system containing air or nitrogen under pressure. The release of the air or nitrogen,(as from the opening of a sprinkler) results in the water pressure opening a valve known as a dry pipe valve, resulting in the flow of water into the piping system and out of the fused sprinklers heads. Dry Sprinkler - ANS A sprinkler secured in an extension nipple that has a seal at the inlet to prevent water from entering the nipple until the sprinkler operates. May be configured with an upright, pendent or sidewall sprinkler. AUTO/NON_AUTO Dry Standpipe - ANS A standpipe system designed to have piping contain water only when the system is being utilized (NO AUTOMATIC WATER SUPPLY) Fire Department Connection - ANS A connection, normally on the exterior of the building. (FORMERLY KNOW AS SIAMESE CONNECTION) Fire Hose - ANS A flexible conduit constructed of one or more reinforcements (JACKETS), Fire Hydrant - ANS A valve connection on a water supply system having one or more outlets and that is used to supply hose and fire department pumps with water. Bulb Sprinkler - ANS A sprinkler operated by heat breaking a glass bulb filled with a non-freezing liquid with diamiter that vary from 3mm for quick response sprinklers to 5mm for standard response sprinklers. Hose Connection - ANS a combination of equipment provided for connection of a hose to the standpipe system that includes a hose valve with a threaded outlet. Hose Station - ANS a combination of a hose rack, hose nozzle, hose, and hose connection. Impairment Coordinator - ANS Person responsible for ensuring the proper safety precautions are taken when the fire protection system is placed out of service (designated by the owner) In Service - ANS The Status of hose stored in a hose house, on a rack or reel, or on a fire apparatus that is available and ready for immediate use at an incident. Personal Supervision - ANS Supervision by the holder of a department certificate who is required to be personally present on the premises, or other proximate location acceptable to the department, while the duties for which the certificate is required is being performed. Pressure Restricting Device - ANS A valve or device designed for the purpose of reducing of reducing the downstream water pressure under both flowing (residual) and non-flowing (static) conditions Pressure Reducing Valve - ANS A valve or device designed for the purpose of reducing of reducing the downstream water pressure under flowing (residual) conditions only. Pressure Tank - ANS A tank using air pressure to supplying water for water-based fire protection systems. Tank contents to be maintained at one third air to two thirds water. Quick Response Sprinkler Head - ANS A sprinkler having a fusible link with a response time index (RTI) of 50 or less. Recessed Sprinkler - ANS A sprinkler in which all or part of the body, other than the shank thread, is mounted above the ceiling. Standpipe System - ANS An arrangement of piping, valves, and hose connections installed in a structure to deliver water for fire hoses. Combination Standpipe and Sprinkler System - ANS A system where the fire protection piping services both 21⁄2 in. (65 mm) outlets for fire department use and outlets for automatic sprinklers. Static Pressure - ANS The measurement of sytem pressure inder NON FLOW CONDITIONS. Standpipe/ Multi-Zone - ANS A standpipe system that is vertically subdivided as required by the construction codes, including the Building Code, into zones to limit the maximum operating pressure in the system. Each zone will have its own individual automatic water supply. Supervisory Signal - ANS A signal indicating the need for action in connection with the supervision of guard tours, fire extinguishing systems or equipment, fire alarm systems or the maintenance features of related systems. Supervisory Signal-Initiating Device - ANS An initiating device, such as a valve supervisory switch, water level indicator, or low-air pressure switch on a dry-pipe or pre-action sprinkler system, that triggers a supervisory signal. Testing - ANS A procedure used to determine the status of a system as intended by conducting periodic physical checks on water based fire protection systems such as water flow tests, fire pump tests, alarm tests, and trip tests of dry pipe or deluge valves. Upright Sprinkler - ANS A sprinkler designed to be installed in such a way that the water spray is directed upwards against the deflector. Water Hammer - ANS The SURGE IN PRESSURE when a high-velocity flow of water is ABRUPTLY SHUT OFF. Water Supply - ANS A source of water that provides the flow (GAL/MIN)(L/MIN) and pressure (PSI) required by the water-based fire protection system. Water Tank - ANS A tank supplying water for ater-based fire protection systems. Wet Standpipe System - ANS A standpipe system having piping containing water at all times. Records - ANS Records of all system inspections, tests, service and other maintenance must be maintained on the premises for a minimum of (3 YEARS). Impairment Coordinator - ANS The person responsible for ensuring that proper safety precautions are taken when a fire protection system is placed out of service. The building owner

Content preview

FDNY Sprinkler Standpipe
System S-12/S-13




A
R
U
LA
C
O
D

, Automatic Standpipe System - ANS A standpipe system that is attached to a water supply
capable of supplying the system demand at all times and that requires no action other than
opening a hose valve to provide water at hose connections.




A
Churning - ANS A condition in a centrifugal in which the impeller is rotating, but no water is
being discharged.




R
Combination Standpipe and Sprinkler System - ANS A system where the water piping
service both 2 1/2in (65) outlet for fire Department use and oulet for automatic sprinkler




U
Concealed Sprinkler - ANS

Deluge Valve - ANS
A recessed sprinkler with a cover plate

water supply control valve intended to be operated by actuation of an
LA
automatic detection system that is installed in the same area as the discharge devices. Suitable
for HAZARDOUS OCCUPANCIES. INTENDED USE IS MANUAL AND AUTO

Deludge Sprinkler System - ANS A sprinkler system employing open sprinklers that are
attached to a piping system that is connected to a water supply through a VALVE that is opened
of a DETECTION SYSTEM installed in the same area as the sprinklers
C

Dry Pipe Sprinkler System - ANS A sprinkler system employing automatic sprinklers that
are attached to a piping system containing air or nitrogen under pressure. The release of the air
or nitrogen,(as from the opening of a sprinkler) results in the water pressure opening a valve
O


known as a dry pipe valve, resulting in the flow of water into the piping system and out of the
fused sprinklers heads.
D



Dry Sprinkler - ANS A sprinkler secured in an extension nipple that has a seal at the inlet to
prevent water from entering the nipple until the sprinkler operates. May be configured with an
upright, pendent or sidewall sprinkler. AUTO/NON_AUTO

Dry Standpipe - ANS A standpipe system designed to have piping contain water only when
the system is being utilized (NO AUTOMATIC WATER SUPPLY)

Fire Department Connection - ANS A connection, normally on the exterior of the building.
(FORMERLY KNOW AS SIAMESE CONNECTION)

Document information

Uploaded on
January 11, 2025
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.39

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DocLaura
4.2
(44)
Sold
160
Followers
38
Items
6394
Last sold
3 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions