CEA Level 1 Exam Questions and
Answers
When drilling into brick or concrete block, you will need _______ plus your protective equipment -
Answer-Hammer drill and masonry bit
T/F When selecting personal protective equipment for protection against air borne particles, a dust
mask is not considered a respirator ` - Answer-False
A ____ bit is required with a hole in the end for the purpose of attaching a wire - Answer-Bell Hanger
A __ is used for pulling wires and cables through a conduit - Answer-Fish Tape
Which of the following is not considered a specialty CCTV tool?
a.) tone generator with probe
b.) compression tool
c.) test monitor
d.) coax stripper - Answer-A
, A hybrid system does which of the following? - Answer--Combines hardwired and wireless technologies
- uses resistors for supervision
- combines technologies allowing you to keep cost down
ALL
Which one is not a component of a CPU?
a.) potentiometer
b.) PGM terminal
c.) heat sink
d.) PIR - Answer-D
T/F primary power should never be unswitched - Answer-False
T/F The function of the communicator is to transmit a signal to a predetermined location - Answer-True
What would you expect in/from an alarm control panel? - Answer-- responds to user inputs
-responds to signals form initialing devices
-activates notifications devices
-performs off-site notifications
ALL
Y/N 24AWG ---> 3.5 MAX CURRENT -----> 88OHMS PER 1000 FT - Answer-yes its current carrying
capacities
T/F Every control panel does not require a means for the customer to submit request for arming,
disarming, bypassing zones or obtain system status and history. - Answer-False
Answers
When drilling into brick or concrete block, you will need _______ plus your protective equipment -
Answer-Hammer drill and masonry bit
T/F When selecting personal protective equipment for protection against air borne particles, a dust
mask is not considered a respirator ` - Answer-False
A ____ bit is required with a hole in the end for the purpose of attaching a wire - Answer-Bell Hanger
A __ is used for pulling wires and cables through a conduit - Answer-Fish Tape
Which of the following is not considered a specialty CCTV tool?
a.) tone generator with probe
b.) compression tool
c.) test monitor
d.) coax stripper - Answer-A
, A hybrid system does which of the following? - Answer--Combines hardwired and wireless technologies
- uses resistors for supervision
- combines technologies allowing you to keep cost down
ALL
Which one is not a component of a CPU?
a.) potentiometer
b.) PGM terminal
c.) heat sink
d.) PIR - Answer-D
T/F primary power should never be unswitched - Answer-False
T/F The function of the communicator is to transmit a signal to a predetermined location - Answer-True
What would you expect in/from an alarm control panel? - Answer-- responds to user inputs
-responds to signals form initialing devices
-activates notifications devices
-performs off-site notifications
ALL
Y/N 24AWG ---> 3.5 MAX CURRENT -----> 88OHMS PER 1000 FT - Answer-yes its current carrying
capacities
T/F Every control panel does not require a means for the customer to submit request for arming,
disarming, bypassing zones or obtain system status and history. - Answer-False