B2- Commercial Building Inspector Practice Test 1 UPDATED ACTUAL Exam Questions and CORRECT Answers Which occupancy group is a Department Store classified as? - CORRECT ANSWER - M Section 309.1 Buildings used for assembly can be classified as a Group B occupancy when the occupant load is less than ___ persons. - CORRECT ANSWER - 50

Content preview

B2- Commercial Building Inspector Practice
Test 1 UPDATED ACTUAL Exam Questions
and CORRECT Answers

Which occupancy group is a Department Store classified as? - CORRECT ANSWER -M


Section 309.1


Buildings used for assembly can be classified as a Group B occupancy when the occupant load is
less than ___ persons. - CORRECT ANSWER - 50


Section 303.1.1


All of the following uses are classified as a Group B occupancy EXCEPT for:
Banks
Post Office
Print Shop

Drug Stores - CORRECT ANSWER - Drug Stores


Section 304.1, 309.1


Structures that contain materials that would pose a health hazard are classified as a Group ___
occupancy. - CORRECT ANSWER - H-4


Section 307.6

,A building used for medical care for more than 5 people who are incapable of self-preservation
on a 24-hour basis is classified as a Group ___ occupancy. - CORRECT ANSWER - I-2


Section 308.4


All of the following facilities are classified as a Group R-2 occupancy EXCEPT for:
Apartment Houses
Monasteries
Transient Hotels

Non-Transient Hotels - CORRECT ANSWER - Transient Hotels


Section 310.4, 310.3


Structures that contain materials that would pose a physical hazard are classified as a Group ___
occupancy. - CORRECT ANSWER - H-3


Section 307.5


Commercial kitchens not associated with restaurants and not more than 2,500 square feet is
classified as a Group ___ occupancy. - CORRECT ANSWER -B


Section 304.1


Incidental uses within a building shall be limited to ___ percent of the building area of the story
in which they are located. - CORRECT ANSWER - 10%


Section 509.3

, Non-sprinklered mixed-occupancy buildings providing a fire separation between Group F-2 and
Group M occupancies shall be separated by a minimum __________. - CORRECT
ANSWER - 2-hour fire barrier/horizontal assembly


Section 508.4, 508.4.4.1, Table 508.4


What is the minimum thickness of a concrete floor slab supported directly on the ground? -
CORRECT ANSWER - 3 1/2


Section 1907.1


An attic space shall be provided with an access opening of not less than ___ inches by ___ inches
and a headroom clearance of not less than ___ inches. - CORRECT ANSWER - 20" x 30",
30"


Section 1209.2


The access requirements for mechanical appliances installed in attic spaces shall be in
accordance with the ______________. - CORRECT ANSWER - IMC (International
Mechanical Code)


Section 1209.3


What is the maximum allowable span of a 2 x 12 Douglas fir-larch #2 floor joist spaced 16
inches on center supporting a living room with a dead load of 20 psf? - CORRECT
ANSWER - 16', 3"


Table 2308.4.2.1(2)


Fire-retardant-treated wood shall not have a moisture content greater than ___ percent for lumber
and no more than ___ percent for wood structural panels. - CORRECT ANSWER - 19, 15

Document information

Uploaded on
December 18, 2024
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
MGRADES
4.0
(230)
Sold
1498
Followers
106
Items
107190
Last sold
22 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions