NCIDQ - IDFX - Practice test 1 | Questions with 100% Correct Answers | Updated
&Verified | 2024-2025 | 100% Score
At what stage would a building analysis be conducted for an existing multi-story structure that is being
renovated and converted from office use to school use?
a. schematics b. master planning c. code analysis d. programming - ✔✔programming
which of the following is the MOST important consideration in planning for a small open office project?
a. management of overall cost per square foot
b. specification of appropriate materials and finishes
c. maintaining ratio between circulation and work area
d. support of job function and relationships - ✔✔support of job function and relationships
what is an appropriate circulation factor for an open office plan using systems furniture?
a. 5%-8%. b. 10%-20%. c. 25%-40%. d. 50%-65% - ✔✔25%-40%
which measurement is an acceptable height for a barrier-free shower seat?
a.14" b.15" c. 18" 3. 20" - ✔✔18"
A client would like to install a window in a 60 min rated door in a corridor. Which of the following would
be acceptable?
a. 10" x 10" wired glass. b. 6" x 12" wired glass. c. 10" x 10" tempered glass. d. 6" x 12" tempered glass -
✔✔10" x 10" wired glass
when converting a 5 bedroom beach house into a bed and breakfast facility, where would a smoke
alarm be required?
a. in the kitchen if its under a sleeping room
b. in the manager's office
c. in each sleeping room
d. outside any shared bathrooms - ✔✔in each sleeping room
&Verified | 2024-2025 | 100% Score
At what stage would a building analysis be conducted for an existing multi-story structure that is being
renovated and converted from office use to school use?
a. schematics b. master planning c. code analysis d. programming - ✔✔programming
which of the following is the MOST important consideration in planning for a small open office project?
a. management of overall cost per square foot
b. specification of appropriate materials and finishes
c. maintaining ratio between circulation and work area
d. support of job function and relationships - ✔✔support of job function and relationships
what is an appropriate circulation factor for an open office plan using systems furniture?
a. 5%-8%. b. 10%-20%. c. 25%-40%. d. 50%-65% - ✔✔25%-40%
which measurement is an acceptable height for a barrier-free shower seat?
a.14" b.15" c. 18" 3. 20" - ✔✔18"
A client would like to install a window in a 60 min rated door in a corridor. Which of the following would
be acceptable?
a. 10" x 10" wired glass. b. 6" x 12" wired glass. c. 10" x 10" tempered glass. d. 6" x 12" tempered glass -
✔✔10" x 10" wired glass
when converting a 5 bedroom beach house into a bed and breakfast facility, where would a smoke
alarm be required?
a. in the kitchen if its under a sleeping room
b. in the manager's office
c. in each sleeping room
d. outside any shared bathrooms - ✔✔in each sleeping room