NICET LEVEL 1 STUDY GUIDE EXAM QUESTIONS AND CORRECT DETAILED / VERIFIED ANSWERS LATEST UPDATE

Document preview thumbnail
Voorbeeld 2 van de 13 pagina's

When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level (NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS rises or falls over 3 inches If combination audible/visible appliances are installed the location of the installed appliance shall be determined by the requirements of _______. (Nfpa 72 18.4.8.1) - ANS the visible appliance What is the maximum number of 12 gauge THHN wires that can be installed in 1" EMT? (Nec Annex C tables) - ANS 26 Two resistors are connected in parallel. R1 = 300 Ohms, R2 = 300 Ohms. What is their equivalent resistance? - ANS 150 ohms A Room is 200' long and 150' wide and the 8' high ceiling is smooth and flat. A spot type heat detector has been selected that is listed for a 50' maximum spacing between detectors. According to NFPA 72 how many detectors will be needed to protect this room? 200 / 50 x 150 / 50 = - ANS 12 According to NFPA 72 the minimum number of restorable fixed temperature spot type heat detectors that must be tested during each annual test is? (NFPA 72 14.4.4.5.1) - ANS Two detectors or more on each initiating device circuit According to NFPA 72 how many spot type heat detectors are required for a space that is 80' long and 55 floor wide with a smooth 10' ceiling? the detector is listed for a maximum space between detectors of 30' - ANS 6 What color code requirement for a spot type heat detector rated at 200゚F - ANS White (NFPA 72, Table 17.6.2.1) Unless otherwise recommended by the manufacturers published instructions single and multiple stations smoke alarms installed in one and 2 family dwellings shall be replaced every - ANS 10 years from the day-of manufacture. (NFPA 72, 14.4.7.1) Fire alarm cables are permitted to be strapped to conduit to support the cable - ANS False (NEC 760.143) Where non power limited wiring is installed exposed it must be mechanically protected within_____of the finished floor - ANS 7' ft When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level (NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS rises or falls over 3 inches If combination audible/visible appliances are installed the location of the installed appliance shall be determined by the requirements of _______. (Nfpa 72 18.4.8.1) - ANS the visible appliance What is the maximum number of 12 gauge THHN wires that can be installed in 1" EMT? (Nec Annex C tables) - ANS 26 Two resistors are connected in parallel. R1 = 300 Ohms, R2 = 300 Ohms. What is their equivalent resistance? - ANS 150 ohms A Room is 200' long and 150' wide and the 8' high ceiling is smooth and flat. A spot type heat detector has been selected that is listed for a 50' maximum spacing between detectors. According to NFPA 72 how many detectors will be needed to protect this room? 200 / 50 x 150 / 50 = - ANS 12 According to NFPA 72 the minimum number of restorable fixed temperature spot type heat detectors that must be tested during each annual test is? (NFPA 72 14.4.4.5.1) - ANS Two detectors or more on each initiating device circuit According to NFPA 72 how many spot type heat detectors are required for a space that is 80' long and 55 floor wide with a smooth 10' ceiling? the detector is listed for a maximum space between detectors of 30' - ANS 6 What color code requirement for a spot type heat detector rated at 200゚F - ANS White (NFPA 72, Table 17.6.2.1) Unless otherwise recommended by the manufacturers published instructions single and multiple stations smoke alarms installed in one and 2 family dwellings shall be replaced every - ANS 10 years from the day-of manufacture. (NFPA 72, 14.4.7.1) Fire alarm cables are permitted to be strapped to conduit to support the cable - ANS False (NEC 760.143) Where non power limited wiring is installed exposed it must be mechanically protected within_____of the finished floor - ANS 7' ft

Voorbeeld van de inhoud

K
C
NICET LEVEL 1 STUDY GUIDE

LO
EXAM QUESTIONS AND
CORRECT DETAILED /
YC
VERIFIED ANSWERS LATEST
UPDATE
D
U
ST

, When testing a water level supervisory switch serving a pressure tank a signal shall indicate if
the water level _____________from the required level

(NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS rises or falls over 3 inches

If combination audible/visible appliances are installed the location of the installed appliance shall
be determined by the requirements of _______.

(Nfpa 72 18.4.8.1) - ANS the visible appliance




K
What is the maximum number of 12 gauge THHN wires that can be installed in 1" EMT?

(Nec Annex C tables) - ANS 26




C
Two resistors are connected in parallel. R1 = 300 Ohms, R2 = 300 Ohms. What is their
equivalent resistance? - ANS 150 ohms




LO
A Room is 200' long and 150' wide and the 8' high ceiling is smooth and flat. A spot type heat
detector has been selected that is listed for a 50' maximum spacing between detectors.
According to NFPA 72 how many detectors will be needed to protect this room?
YC
x = - ANS 12

According to NFPA 72 the minimum number of restorable fixed temperature spot type heat
detectors that must be tested during each annual test is?

(NFPA 72 14.4.4.5.1) - ANS Two detectors or more on each initiating device circuit
D

According to NFPA 72 how many spot type heat detectors are required for a space that is 80'
long and 55 floor wide with a smooth 10' ceiling? the detector is listed for a maximum space
U


between detectors of 30' - ANS 6

What color code requirement for a spot type heat detector rated at 200゚F - ANS White (NFPA
ST




72, Table 17.6.2.1)

Unless otherwise recommended by the manufacturers published instructions single and multiple
stations smoke alarms installed in one and 2 family dwellings shall be replaced every - ANS 10
years from the day-of manufacture. (NFPA 72, 14.4.7.1)

Fire alarm cables are permitted to be strapped to conduit to support the cable - ANS False
(NEC 760.143)

Where non power limited wiring is installed exposed it must be mechanically protected
within_____of the finished floor - ANS 7' ft

Documentinformatie

Geüpload op
7 december 2024
Aantal pagina's
13
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
$11.49

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Studyclock
4.2
(234)
Verkocht
886
Volgers
492
Items
8765
Laatst verkocht
1 week geleden



Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen