• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 111 pages
Exam (elaborations)

SURGICAL TECHNOLOGY CERTIFICATION EXAM QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY GRADED A+ LATEST UPDATE |

Document preview thumbnail
Preview 4 out of 111 pages

The surgeon asks that multiple suture and hernia mesh that were not on the preference card be opened during the repair of a large umbilical hernia. The surgical technologist should recognize that: a. items on the preference card are only to be changed by the surgeon or the unit clerk b. sterile supply associates who stock the hernia mesh are responsible for adding hernia mesh to the preference card c. preference card changes are unnecessary; both hernia mesh and suture are case dependent. d. suture may be case dependent, but the hernia mesh is integral to the procedure and should be added to the preference card Ans Answer: D Which of the following precautions should be taken by the surgical team when working with polymethyl methacrylate as a bone cement? o Thank You for Choosing Us! o © 2024 TestTrackers o Customer Support: [] o Resources & Updates: [Testtrackers - Stuvia US] o Your Success is Our Mission! TestTrackers: Unlock Your Exam Potential! | Quality Practice Materials | Boost Your Confidence Today! a. wear latex free gloves, as polymethyl methacrylate interacts negatively with latex b. remove contact lenses as polymethyl methacrylate can melt contact lenses and cause corneal burns c. make sure the patient does not have a latex allergy because polymethyl methacrylate and latex have the same chemical properties d. Limit the # of sponges on the field as polymethyl methacrylate can negatively interact with the cotton fibers in the sponges. Ans Answer: B Which of the following daily tests must be performed on the pre-vacuum sterilizer before using it? a. Gravity b. Biological indicator c. Bowie-Dick d. Chemical indicator Ans o Thank You for Choosing Us! o © 2024 TestTrackers o Customer Support: [] o Resources & Updates: [Testtrackers - Stuvia US] o Your Success is Our Mission! TestTrackers: Unlock Your Exam Potential! | Quality Practice Materials | Boost Your Confidence Today! Answer: C What is the minimum exposure time in a flash sterilizer for unwrapped instruments? a. 1 minute b. 3 minutes c. 5 minutes d. 7 minutes Ans Answer: B [pre-vac] no lumen - 3 minutes ; lumen - 4 minutes Which of the following is the correct temperature for the flash sterilizer operation? a. 132*C (270*F) b. 126*C (260*F) c. 135*C (275*F) d. 129*C (265*F) Ans o Thank You for Choosing Us! o © 2024 TestTrackers o Customer Support: [] o Resources & Updates: [Testtrackers - Stuvia US] o Your Success is Our Mission! TestTrackers: Unlock Your Exam Potential! | Quality Practice Materials | Boost Your Confidence Today! Answer: A Which of the following is the proper temperature and time that the chamber of a steam sterilizer must reach in order to ensure that all spores have been eliminated? a. 270*F for 4 minutes b. 350*F for 4 minutes c. 240*F for 10 minutes d. 350*F for

Content preview

o Thank You for Choosing Us! o Resources & Updates: [Testtrackers - Stuvia
o © 2024 TestTrackers
o Customer Support: [+254707240657]
US]
o Your Success is Our Mission!




SURGICAL TECHNOLOGY CERTIFICATION
EXAM QUESTIONS AND CORRECT DETAILED
ANSWERS |ALREADY GRADED A+ LATEST
UPDATE | 2024-2025
The surgeon asks that multiple suture and hernia mesh that were not on the

preference card be opened during the repair of a large umbilical hernia. The

surgical technologist should recognize that:

a. items on the preference card are only to be changed by the surgeon or the

unit clerk

b. sterile supply associates who stock the hernia mesh are responsible for

adding hernia mesh to the preference card

c. preference card changes are unnecessary; both hernia mesh and suture are

case dependent.

d. suture may be case dependent, but the hernia mesh is integral to the

procedure and should be added to the preference card

Ans

Answer: D




Which of the following precautions should be taken by the surgical team when

working with polymethyl methacrylate as a bone cement?
TestTrackers: Unlock Your Exam Potential! | Quality Practice Materials | Boost Your Confidence
Today!

,o Thank You for Choosing Us! o Resources & Updates: [Testtrackers - Stuvia
o © 2024 TestTrackers
o Customer Support: [+254707240657]
US]
o Your Success is Our Mission!


a. wear latex free gloves, as polymethyl methacrylate interacts negatively with

latex

b. remove contact lenses as polymethyl methacrylate can melt contact lenses

and cause corneal burns

c. make sure the patient does not have a latex allergy because polymethyl

methacrylate and latex have the same chemical properties

d. Limit the # of sponges on the field as polymethyl methacrylate can negatively

interact with the cotton fibers in the sponges.

Ans

Answer: B




Which of the following daily tests must be performed on the pre-vacuum

sterilizer before using it?

a. Gravity

b. Biological indicator

c. Bowie-Dick

d. Chemical indicator

Ans


TestTrackers: Unlock Your Exam Potential! | Quality Practice Materials | Boost Your Confidence
Today!

,o Thank You for Choosing Us! o Resources & Updates: [Testtrackers - Stuvia
o © 2024 TestTrackers
o Customer Support: [+254707240657]
US]
o Your Success is Our Mission!

Answer: C




What is the minimum exposure time in a flash sterilizer for unwrapped

instruments?

a. 1 minute

b. 3 minutes

c. 5 minutes

d. 7 minutes

Ans

Answer: B

[pre-vac] no lumen - 3 minutes ; lumen - 4 minutes




Which of the following is the correct temperature for the flash sterilizer

operation?

a. 132*C (270*F)

b. 126*C (260*F)

c. 135*C (275*F)

d. 129*C (265*F)

Ans
TestTrackers: Unlock Your Exam Potential! | Quality Practice Materials | Boost Your Confidence
Today!

, o Thank You for Choosing Us! o Resources & Updates: [Testtrackers - Stuvia
o © 2024 TestTrackers
o Customer Support: [+254707240657]
US]
o Your Success is Our Mission!

Answer: A




Which of the following is the proper temperature and time that the chamber

of a steam sterilizer must reach in order to ensure that all spores have been

eliminated?

a. 270*F for 4 minutes

b. 350*F for 4 minutes

c. 240*F for 10 minutes

d. 350*F for 10 mintues

Ans

Answer: A

[pre-vac] temp: 270*F ; time: 3-4 minutes ; pressure: 27 psi




The Sterrad sterilization system most commonly uses which of the following

chemical solutions?

a. hydrogen peroxide

b. gluteraldehyde

c. alcohol

d. peracetic acid
TestTrackers: Unlock Your Exam Potential! | Quality Practice Materials | Boost Your Confidence
Today!

Document information

Uploaded on
December 2, 2024
Number of pages
111
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$14.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ScholarsAscend
3.7
(82)
Sold
500
Followers
39
Items
30002
Last sold
17 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions