Journeyman's Exam 258 complete Solutions 100% correct. Journeyman's Exam 258 complete Solutions 100% correct. Journeyman's Exam 258 complete Solutions 100% correct. Journeyman's Exam 258 complete Solutions 100% correct. Journeyman's Exam 258 complete Solutions 100% correct. Journeyman's Exam 258 complete Solutions 100% correct. Journeyman's Exam 258 complete Solutions 100% correct. Journeyman's Exam 258 complete Solutions 100% correct. Journeyman's Exam 258 complete Solutions 100% correct. Journeyman's Exam 258 complete Solutions 100% correct. Journeyman's Exam 258 complete Solutions 100% correct. Journeyman's Exam 258 complete Solutions 100% correct. Journeyman's Exam 258 complete Solutions 100% correct.

Content preview

Journeyman's Exam 258 complete
Solutions 100% correct.
Journeyman's Exam 258 complete
Solutions 100% correct.
1/4" - ANSWER-Threads of drainage fittings shall be tapped as to allow _____ pitch per
foot

4 lbs - ANSWER-Lead used for safe pans shall not be less than ________ per square
foot

Copper Tube, Cast Iron, Stainless steel, ABS, PVC DWV - ANSWER-Name 3 allowable
materials for the DWV system "underground"

1-1/4" - 1 dfu's
1-1/2" - 3 dfu's
2" - 4 dfu's
3" 6 dfu's
4" - dfu's - ANSWER-What are the fixture unit values for the following traps

Double fixture fitting - ANSWER-What type of fitting is used for continuous waste and
venting of lavatories back to back?

1" - ANSWER-Caulk joints for cast iron bell and spigot shall be filled with molten lead to
a depth of not less than ________?

Wye, Combination Wye w/ 1/8 bend, Long sweep - ANSWER-What type of fitting or
fittings can be used to connect horizontal drainage to another horizontal drainage line?

- Each horizontal drainage pipe shall be provided with a cleat at its upper terminal
- Horizontal run more than 100'
- Each horizontal change of direction exceeding 135°
- Front Main Cleanout - ANSWER-Cleanout locations required by code

100' - ANSWER-Maximum distance a cleanup can be spaced apart

12"
18" - ANSWER-Minimum clearance in front of a cleanup for 2" or less
Minimum clearance in front of a cleanup for 2" or more

20' - ANSWER-Underfloor cleanup shall not be located more than _____ from an
access door, trap door, or crawl hole

,Journeyman's Exam 258 complete
Solutions 100% correct.
Back Water Valve - ANSWER-When plumbing fixtures are installed on a floor level
lower than the next upstream manhole cover of the sewer, such drainage piping shall be
protected from backflow of sewage by a ____________

20 - ANSWER-Sewage ejectors receiving the discharge of water closets or ruinals shall
have a discharge capacity not less than ___ gallons per minute

2" - ANSWER-What is the minimum size discharge pipe for an ejector installed in a
single dwelling?

2" - ANSWER-The lowest inlet connected to the ejector pump shall have a clearance of
not less than ____ from the high water or starting level of the sump.

Yes, with prior approval of the AHJ - ANSWER-Can macerating toilet systems be
installed instead of a sewage pump system

3/4" - ANSWER-What is the minimum size discharge pipe for a macerating toilet system

1/4" per foot - ANSWER-What is the minimum pitch required fora 2" horizontal drain?

Swing check valve - ANSWER-The discharge line from an ejector pump shall be
provided with an accessible ___________ and gate or ball valve.

Downstream of the backwater valve - ANSWER-Where shall the gate valve be located
on the discharge line on an ejector pump

8' - ANSWER-Drainage connections shall not be made into a drainage piping system
within ________ of an vertical or horizontal change in direction of a stack containing
suds producing fixtures.

10' Head of water for 15 minutes
5 psi for and air test - ANSWER-What are the requirements when testing the DWV
system Water and Air?

When the dwelling is more than 200' away from the sewer. - ANSWER-When is the
public sewer considered not being available?

2' away from the building - ANSWER-At what point does the building sewer begin?

DFU's - ANSWER-How is the size of the building sewer determined?

300' - ANSWER-What is the maximum distance allowed between approved manholes?

, Journeyman's Exam 258 complete
Solutions 100% correct.
12" - ANSWER-When a water pipe and sewer pipe are placed in a common trench what
is the minimum distance above the top of the sewer line to the bottom of the water pipe?

12" - ANSWER-When a water pipe and sewer pipe are placed in a common trench what
is the minimum clear horizontal distance the water pipe shall be from the sewer pipe?

By taking 80% of the total DFU's = 173 DFU's - ANSWER-A 4' drainage line has to be
run at a pitch of 1/8" per foot. How is the maximum fixture unit low now determined?

Provide minimum requirements and standards for the protection of the public health,
safety, and welfare. - ANSWER-Purpose of plumbing code.

Capped - ANSWER-Openings into drainage or vent system excepting those opening to
which plumbing fixtures are properly connected or which constitute vent terminals shall
be permanently plugged or _________ in an approved manner.

Owner or owners agent - ANSWER-Who is responsible for maintaining the plumbing
and drainage system in a building?

Work or systems that have already been installed prior to the effective date of the
existing code. - ANSWER-What is meant by the term "existing work"?

Blockages or leaks - ANSWER-What type of work is exempt from a plumbing permit?

180 Days - ANSWER-If work is not started, how many days is a permit valid?

After it has been tested, inspected, and approved - ANSWER-When can plumbing work
be covered and concealed?

Person with the permit, doing the work - ANSWER-Who notifies the authority have
jurisdiction when plumbing work is ready for inspections?

Prevent siphonage - ANSWER-What is the purpose of a vacuum relief valve

To slow corrosion of the inside of the tank - ANSWER-What is the purpose of the anode
rod?

To send cold water to the bottom of the tank - ANSWER-What is the purpose of the dip
tube?

To prevent siphonage and back pressure on the dip tube. - ANSWER-What is the
purpose of the anti-siphon hole?

Document information

Uploaded on
November 27, 2024
Number of pages
19
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$9.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
APPROVEDNURSE
3.2
(5)
Sold
37
Followers
20
Items
1552
Last sold
8 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions