Pulmonary
Pulmonary
Function
Diagnostic
Testing
Pulmonary
Testing
Pulmonary
Kettering
Function
Diagnostic
Study
Testing
Guide
Testing
Pulmonary
Practice
Kettering
Diagnostic
Questions.pdf
Study Guide
Testing
Practice
Kettering
Questions.pdf
Study Guide Practice Questions.pdf
Pulmonary Function Testing Pulmonary
Diagnostic Testing Kettering Study
Guide Practice Questions
Guidehttps://www.stuvia.com/dashboard!@_)#*)(@$)($@*($@)($@*_
Pulmonary Function Testing
Pulmonary
Pulmonary
Function
Diagnostic
Testing
Pulmonary
Testing
Pulmonary
Kettering
Function
Diagnostic
Study
Testing
Guide
Testing
Pulmonary
Practice
Kettering
Diagnostic
Questions.pdf
Study Guide
Testing
Practice
Kettering
Questions.pdf
Study Guide Practice Questions.pdf
,Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf
Terms in this set (47)
What 2 values do Spirometers measure? Volume and flow rates
What does a Pneumotachometer measure? Flow
What are the 2 types of Pneumotachometers? 1) Turbine (Wright respirometer)
2) Pressure Differential
What is the peak flow meter? device for asthma pts to measure the Peak expiratory flow rate at bedside
Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf
,Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf
Which value is recorded out of 3 times on a Peak the highest of 3
flow measurement?
What is the typicaly peak flow value for an adult? 10 L/sec or 600 L/min
What does the Plethysmograph (body box) Thoracic gas volume (FRC)
measure?
What is the advantage of the body box? Accurately measures the FRC in pts with Obstructive lung dieseases
Daily Calibration of PFT equipment should be a 3 liter Super syringe
performed with what?
The respirator therapist is unable to calibrate a Change fuel cell
galvanic fuel cell analyzer. What should the therapist
do?
What can effect the accuracy of the Galvanic Fuel Water or changes in altitude
cell?
Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf
, Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf Pulmonary Function Testing (Pulmonary Diagnostic Testing) (kettering).pdf
What is the difference of the Polarographic Uses a battery to polarize electrodes
compared to the Galvanic fuel cell?
Accurate Oxygen analyzers must be in what range within 2% of known value
of know value?
What are the 2 Pressure Measuring devices 1) Water Manometer/ Barometer
2) Aneroid Manometer (Blood pressure)