100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Plumbing Red Seal Revised Exam Questions And Solutions

Rating
-
Sold
-
Pages
20
Grade
A+
Uploaded on
21-11-2024
Written in
2024/2025

Plumbing Red Seal Revised Exam Questions And Solutions Trap arms and fixture drains are to be installed with roughly _____ of an inch downward slope for every foot of trap arm length - answers1/4" per foot less than 3" - 1/8" per foot 4" and higher What can put a great deal of stress on your neck, shoulders, back, and legs when lifting heavy objects? - answersnot bending at your knees and keeping your back straight The Propane Storage and Handling Code is ______________. - answersB149.2-00 The wires of a thermostat are wired to terminals - answersR,W,G The ideal location for a circulator pump installed in a hot water heating system is - answerson the supply after the expansion tank A toilet seat used in a public washroom must be - answerselongated open front type The most common physical characteristics used to measure the quality of water are: temperature, taste, colour, _________ and odour - answersturbidity When using grooved pipe from one manufacturer, the fittings from another manufacturer may be used. - answersFalse A settlement loop is installed in water distribution lines that are ______ inches or less - answers2 Which of the following must the base of every soil or waste stack contain - answerscleanout and expansion joint An oil interceptor would most likely be found in a/an: - answersdry cleaning plant. A water purveyor has the primary responsibility of: - answersproviding the public with a safe and potable water supply. A one inch water service to a building may have a _____ valve as the shut-off valve for the building. - answersstop-and-drain An air conditioner that discharges 0.05 L/s of condensate into a floor drain, would equate to how many fixture units? - answers2 After the inspection of a hot water heating system shows that the system pressure is in excess of the designed operating pressure. Which device will cause this problem? - answersWater-feed valve. The state in which matter exists can be influence by these two factors: - answerstemperature and pressure If the zone valve drive motor fails to operate the plumber must: - answersreplace the defective motor. A 120 Volt hot surface igniter can reach temperatures up to ____F - answers2600 Which of the following best describes an electric water heater? - answersone with an immersion type element A trap arm that does not use siphonic action may change direction in a horizontal plane by up to ____ degrees between the fixture and the vent fitting - answers135 The suction pipe from the well to the house should be installed at a/an _______ slope - answersupward The maximum filling density of any propane container must never exceed ____% of the water capacity stamped on the container - answers42 1. When installing a private water supply system, a qualified __________ should complete all wiring terminations - answerselectrician If a wood range is to be converted to a gas range certain adjustments must be made. One major adjustment is the: - answersreplacement of manual dampers with barometric dampers When an eye is properly formed in a wire rope with the use of a thimble, the eye will have approximately ______ percent - answers80 A fixture drain of the individual fixture that is not piped through one complete storey is referred to as a: - answersfixture drain. Fixtures that are not part of a wet vent group may connect to the wet vent branch and the hydraulic load going into the vent does not have to be included in the wet vent - answersFalse When calculating the fixture unit load of a residence a two inch main floor drain is considered to be ____ fixture units. - answers2 The common name for sodium carbonate is _________. - answerssoda ash When a series of water treatment devices are required for a water treatment system the water softener is always located _________ in the series. - answersLast Which of the following will have the lowest supply pressure - answersmanufactured gas Which table should be consulted to determine cleanout size and spacing - answers4.7.2

Show more Read less
Institution
Plumbing Red Seal A
Course
Plumbing Red Seal A










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Plumbing Red Seal A
Course
Plumbing Red Seal A

Document information

Uploaded on
November 21, 2024
Number of pages
20
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

©JUSTTRACY EXAM SOLUTIONS
21/11/2024 11:15AM



Plumbing Red Seal Revised Exam
Questions And Solutions
Trap arms and fixture drains are to be installed with roughly _____ of an inch downward
slope for every foot of trap arm length - answers✔✔1/4" per foot less than 3" - 1/8" per foot
4" and higher


What can put a great deal of stress on your neck, shoulders, back, and legs when lifting heavy
objects? - answers✔✔not bending at your knees and keeping your back straight



The Propane Storage and Handling Code is ______________. - answers✔✔B149.2-00


The wires of a thermostat are wired to terminals - answers✔✔R,W,G


The ideal location for a circulator pump installed in a hot water heating system is -
answers✔✔on the supply after the expansion tank



A toilet seat used in a public washroom must be - answers✔✔elongated open front type


The most common physical characteristics used to measure the quality of water are:
temperature, taste, colour, _________ and odour - answers✔✔turbidity


When using grooved pipe from one manufacturer, the fittings from another manufacturer may
be used. - answers✔✔False


A settlement loop is installed in water distribution lines that are ______ inches or less -
answers✔✔2


Which of the following must the base of every soil or waste stack contain -
answers✔✔cleanout and expansion joint

, ©JUSTTRACY EXAM SOLUTIONS
21/11/2024 11:15AM

An oil interceptor would most likely be found in a/an: - answers✔✔dry cleaning plant.


A water purveyor has the primary responsibility of: - answers✔✔providing the public with a
safe and potable water supply.


A one inch water service to a building may have a _____ valve as the shut-off valve for the
building. - answers✔✔stop-and-drain


An air conditioner that discharges 0.05 L/s of condensate into a floor drain, would equate to
how many fixture units? - answers✔✔2


After the inspection of a hot water heating system shows that the system pressure is in excess
of the designed operating pressure. Which device will cause this problem? -
answers✔✔Water-feed valve.


The state in which matter exists can be influence by these two factors: -
answers✔✔temperature and pressure



If the zone valve drive motor fails to operate the plumber must: - answers✔✔replace the
defective motor.


A 120 Volt hot surface igniter can reach temperatures up to ____F - answers✔✔2600



Which of the following best describes an electric water heater? - answers✔✔one with an
immersion type element


A trap arm that does not use siphonic action may change direction in a horizontal plane by up
to ____ degrees between the fixture and the vent fitting - answers✔✔135


The suction pipe from the well to the house should be installed at a/an _______ slope -
answers✔✔upward

, ©JUSTTRACY EXAM SOLUTIONS
21/11/2024 11:15AM

The maximum filling density of any propane container must never exceed ____% of the
water capacity stamped on the container - answers✔✔42


1. When installing a private water supply system, a qualified __________ should complete all
wiring terminations - answers✔✔electrician


If a wood range is to be converted to a gas range certain adjustments must be made. One
major adjustment is the: - answers✔✔replacement of manual dampers with barometric
dampers


When an eye is properly formed in a wire rope with the use of a thimble, the eye will have
approximately ______ percent - answers✔✔80


A fixture drain of the individual fixture that is not piped through one complete storey is
referred to as a: - answers✔✔fixture drain.


Fixtures that are not part of a wet vent group may connect to the wet vent branch and the
hydraulic load going into the vent does not have to be included in the wet vent -
answers✔✔False


When calculating the fixture unit load of a residence a two inch main floor drain is
considered to be ____ fixture units. - answers✔✔2



The common name for sodium carbonate is _________. - answers✔✔soda ash


When a series of water treatment devices are required for a water treatment system the water
softener is always located _________ in the series. - answers✔✔Last


Which of the following will have the lowest supply pressure - answers✔✔manufactured gas



Which table should be consulted to determine cleanout size and spacing - answers✔✔4.7.2
$8.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
JustTracy

Get to know the seller

Seller avatar
JustTracy Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
1
Member since
1 year
Number of followers
0
Documents
298
Last sold
10 months ago

Timely Exam Questions With Verified Answers And Package Deal.

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions