Essentials of Fire Fighting 7th Edition -
Chapter 11 Tactical Ventilation
Questions and Complete Solutions
Graded A+
What is an example of mechanical horizontal ventilation?



A. Creating openings on the windward and leeward side

B. Using a fan to create positive pressure inside a structure

C. Making long trench cuts on the roof for defensive operations

D. Using power tools to make as many exhaust openings as possible - Answer: B. Using a fan to create
positive pressure inside a structure



Chapter 11 - page 507



When ventilating windowless buildings:



A. The normal HVAC system should be kept running or turned on

B. The best option will be to cut openings in the walls and/or roofs

C. Mechanical ventilation is generally ineffective in removing hot gases and smoke

D. HVAC systems need to be brought under fire department control as soon as possible - Answer: D.
HVAC systems need to be brought under fire department control as soon as possible



Chapter 11 - page 525



Never direct a __________ a horizontal exhaust opening when interior attack crews are inside the
structure because it will force smoke, heat, and steam toward them.



A. Fog stream into

,B. Solid stream into

C. Fog stream out of

D. Solid stream out of - Answer: A. Fog stream into



Chapter 11 - page 507



Firefighters should never direct a fog stream into a vertical exhaust opening when:



A. Flames can be seen through the opening

B. Black smoke is coming from the opening

C. Interior attack crews are inside the structure

D. Other openings in the structure already exist - Answer: C. Interior attack crews are inside the
structure



Chapter 11 - page 516



What type of fires would likely cause firefighters to have to descend through intense rising heat and
smoke to get to the seat of the fire if ventilation is not effective?



A. Garage fires

B. High rise fires

C. Basement fires

D. Commercial structure fires - Answer: C. Basement fires



Chapter 11 - page 522



The two primary types of inspection holes cut in roofs are the kerf cut and the:



A. Trench cut

, B. Square cut

C. Louver cut

D. Triangle cut - Answer: D. Triangle cut



Chapter 11 - page 518



What is a safety precaution that should be observed during vertical ventilation?



A. Remain on the roof after ventilation work is completed

B. When using a power saw, make sure that the angle of the cut is away from the body

C. Do not start a power saw on the ground; ensure operation once it has been brought to the roof

D. When operating from aerial ladder platforms, the floor of the platform should be slightly below roof
level - Answer: B. When using a power saw, make sure that the angle of the cut is away from the body



Chapter 11 - page 515



In what type of scenario would the IC order firefighters to create a trench cut?



A. Only a minimal amount of personnel are available

B. The main body of the fire is too large to extinguish

C. The fire is reasonably contained within a single compartment

D. Ventilation needs to be completed quickly and with little risk - Answer: B. The main body of the fire is
too large to extinguish



Chapter 11 - page 520



What is the BEST description of how to conduct inspection and maintenance of ventilation equipment?



A. Follow manufacturer instructions for inspecting and maintaining power tools

Document information

Uploaded on
November 16, 2024
Number of pages
19
Written in
2024/2025
Type
Exam (elaborations)
Contains
Unknown
$14.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
YourExamplug
4.1
(74)
Sold
223
Followers
27
Items
18055
Last sold
3 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions