IEC 213 QUESTIONS & VERIFIED
RATIONALIZED ANSWERS 100%
GUARANTEE PASS

vWhen the corrected ampacity of a 10 AWG copper conductor is 12.86 amps, the maximum size circuit
breaker permitted to protect the conductors is ___. - 15



According to 240.4(D)(7), the largest circuit breaker that can be used to protect a circuit that uses 10
AWG conductors has a rating of ___ A. - 30



A 240-volt load, such as a window unit air conditioner, would require breaker ___ to be installed in the
panelboard. - b



Generally, circuit breakers must be ___. - readily accessible



What is the maximum voltage between circuit conductors when using plug fuses? - 125



Refer to Figure 204.5. The conductors at Point I are ___. - taps



Where installed in a 3-pole, 600-volt fused safety switch, the minimum number of fuses required to
protect a 120-volt, 1-ph, 2-wire branch circuit is ___. - 1



The secondary of a 300 KVA, 480 - 240-volt Δ-Δ transformer is delivering 100 amps to 3Ø loads. Based on
this load, the smallest permitted primary and secondary conductors are installed.



Refer to Scenario 223.51. The maximum rating of the primary OCPD is ___ A. - 100



The secondary of a 300 KVA transformer delivers power to a 180-amp, 3Ø load. This is a 480 — 240 volt
Δ-Δ transformer. Primary and secondary conductors are the minimum size required to serve the load.

, Refer to Scenario 220.53. The secondary OCPD can have a rating no greater than ___ amps. - 200



Section 240.21(C)(6) in the NEC® is the "25 foot rule." This section requires that the secondary
conductors be 25 feet or shorter in length and ___.



I. have an ampacity that is ≥ [(Pri OCPD ÷ 3) × (Epri line ÷ Esec line)]

II. have an ampacity that is ≥ the rating of the circuit breaker or fuses at the end

III. be installed in a raceway or otherwise protected from physical damage - I, II, & III



Circuit breakers shall be marked with a voltage rating not less than the nominal system voltage that is
indicative of their capability to interrupt fault currents ___.

I. between phases

II. from phase to ground

III. between the neutral and ground - I & II only



Handles or levers of circuit breakers, and similar parts which may move suddenly in such a way that
persons in the vicinity are likely to be injured by being struck by them, shall be ___.

I. concealed

II. isolated

III. guarded - II or III only



If a fuse label is not marked with a fuse interrupting rating, the fuse size has ___. - an interrupting rating
of 10,000 amps



A conductor has a computed ampacity of 75 amps. What is the maximum standard ampere rating of the
overcurrent protection device the NEC® permits to protect this circuit? This is not a motor circuit or part
of a multioutlet branch circuit supplying receptacles. - 80 amperes



If the allowable current rating of a busway is 1400 amps, what is the maximum allowable rating of the
overcurrent protection device that may be used to protect the busway? - 1200 amps

Document information

Uploaded on
November 15, 2024
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
edunurse
3.6
(19)
Sold
156
Followers
13
Items
6803
Last sold
2 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions