• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 5 pages
Exam (elaborations)

UST Designated Operator A

Document preview thumbnail
Preview 2 out of 5 pages

What must owners and operators do if their UST fails the internal lining inspection and cannot be repaired according to a code of practice? - answer-Permanently close the UST T/F Cathodic protection tester can design field-installed cathodic protection systems - answer-False T/F Owners and operators have 30 days to respond to an active alarm on their automatic tank gauging console. - answer-False T/F An inconclusive result for SIR means an owner and operator has not performed release detection for that month. - answer-True How many years must owners and operators maintain performance claims for their release detection method? - answer-5 Years Owners and operators with 100 or fewer USTs must have ____ dollars aggregate coverage for tanking corrective action and compensating third parties - answer-1 Million T/F Owners and operators may use a combination of financial mechanisms to comply with the financial responsibility requirements. - answer-True T/F Tanks less than 10,000 gallons installed after April 11, 2016 do not have to meet the secondary containment requirement. - answer-False Owners and operators must notify EPA at least 30 days prior to permanently closing an UST system or performing a change-in-service by doing what? - answer-Call EPA E-mail EPA Mail by U.S Postal Service Containment sumps include which of the following? - answer-Under-Dispenser Containment Submersible Turbine pump sump Transition Sump Owners and operators must demonstrate compatibility for which of the following stored substances? - answer-B50 E15 T/F All components of UST systems are designed for all blends of ethanol in the fuel. - answer-False T/F Double-walled spill buckets where the space between the walls of the spill bucket is no longer monitored at least 30 days must be tested for liquid tightness within 1 year after monitoring ceases. - answer-False What percent of piping can an owner or operator repair and not have to replace the piping with secondarily contained piping? - answer-Less than 50 percent T/F Owners and operators need to check hand held release detection equipment for operability and serviceability at least annually - answer-True How often must owners and operators conduct containment sump testing for containment sumps used for piping interstitial monitoring? - answer-3 years T/F Manual tank gauging can be used to meet the release detection monitoring requirement for any size tank. - answer-False T/F Pressurized piping must use an automatic line leak detector. - answer-True Automatic line leak detectors must be capable of detecting a release of ____ galls per hour at a pressure of _____ PSI within 1 hour - answer-3 Gallons per hour at 10 PSI How often must an UST be monitored for releases using release detection? - answer-30 days Select the equipment used in UST systems installed after October 13, 2015 where the first three-year test or inspection must take place at installation. - answer-Automatic shutoff devices, high level alarms, and single-wall spell buckets receiving deliveries of more than 25 gallons installed after October 13th, 2015 must have a first three-year test or inspection at installation. Select the spill and overfill prevention equipment installed before October 13, 2015, where the first three-year test or inspection must take place by October 13, 2018. - answer-All of the equipment shown requires the first three-year test or inspection T/F Owners and operators are not required to perform release detection during temporary closure if the UST is empty. - answer-True How long must records of operators training be maintaned? - answer-As long as the operator is designated at the facility. T/F Operator training records must be in paper format and may not be maintained electronically. - answer-False T/F The two main types of corrosion protection on upgraded steel tanks are cathodic protection and internal lining. - answer-True As stated in the federal UST regulation, a spill or overflow of how many gallons that results in a release of petroleum to the environment mist be reported to the implementing agency? - answer-Greater than 25 Gallons T/F For tanks installed after April 11, 2016 continuous in tank monitoring is an allowable form of release detection. - answer-False T/F Internally lined tanks must be inspected at least once every 3 years to make sure the lining is performing according to original design specifications - answer-False T/F Fiberglass and flexible plastic piping do not need to have cathodic protection - answer-True T/F Owners and operators must report a suspected release if the unexplained presence of water is found in the tank - answer-True Which type of piping does not require release detection if it were installed or replaced after April 11, 2016 and met all design criteria? - answer-Safe-Suction Piping Choose the UST system component that must be tested annually by October 13, 2019 for operability. The test involved simulating a leak to determine that the component is capable of detecting a leak at or below 3 gallons per hour at 10 pounds per square inch line pressure within 1 hour. - answer-Electronic Line Leak Detectors

Content preview

UST Designated Operator A
What must owners and operators do if their UST fails the internal lining inspection
and cannot be repaired according to a code of practice? - answer-Permanently close
the UST

T/F Cathodic protection tester can design field-installed cathodic protection systems
- answer-False

T/F Owners and operators have 30 days to respond to an active alarm on their
automatic tank gauging console. - answer-False

T/F An inconclusive result for SIR means an owner and operator has not performed
release detection for that month. - answer-True

How many years must owners and operators maintain performance claims for their
release detection method? - answer-5 Years

Owners and operators with 100 or fewer USTs must have ____ dollars aggregate
coverage for tanking corrective action and compensating third parties - answer-1
Million

T/F Owners and operators may use a combination of financial mechanisms to
comply with the financial responsibility requirements. - answer-True

T/F Tanks less than 10,000 gallons installed after April 11, 2016 do not have to
meet the secondary containment requirement. - answer-False

Owners and operators must notify EPA at least 30 days prior to permanently closing
an UST system or performing a change-in-service by doing what? - answer-Call EPA
E-mail EPA
Mail by U.S Postal Service

Containment sumps include which of the following? - answer-Under-Dispenser
Containment
Submersible Turbine pump sump
Transition Sump

Owners and operators must demonstrate compatibility for which of the following
stored substances? - answer-B50
E15

T/F All components of UST systems are designed for all blends of ethanol in the fuel.
- answer-False

T/F Double-walled spill buckets where the space between the walls of the spill
bucket is no longer monitored at least 30 days must be tested for liquid tightness
within 1 year after monitoring ceases. - answer-False

, What percent of piping can an owner or operator repair and not have to replace the
piping with secondarily contained piping? - answer-Less than 50 percent

T/F Owners and operators need to check hand held release detection equipment for
operability and serviceability at least annually - answer-True

How often must owners and operators conduct containment sump testing for
containment sumps used for piping interstitial monitoring? - answer-3 years

T/F Manual tank gauging can be used to meet the release detection monitoring
requirement for any size tank. - answer-False

T/F Pressurized piping must use an automatic line leak detector. - answer-True

Automatic line leak detectors must be capable of detecting a release of ____ galls
per hour at a pressure of _____ PSI within 1 hour - answer-3 Gallons per hour at 10
PSI

How often must an UST be monitored for releases using release detection? -
answer-30 days

Select the equipment used in UST systems installed after October 13, 2015 where
the first three-year test or inspection must take place at installation. - answer-
Automatic shutoff devices, high level alarms, and single-wall spell buckets receiving
deliveries of more than 25 gallons installed after October 13th, 2015 must have a
first three-year test or inspection at installation.

Select the spill and overfill prevention equipment installed before October 13, 2015,
where the first three-year test or inspection must take place by October 13, 2018. -
answer-All of the equipment shown requires the first three-year test or inspection

T/F Owners and operators are not required to perform release detection during
temporary closure if the UST is empty. - answer-True

How long must records of operators training be maintaned? - answer-As long as the
operator is designated at the facility.

T/F Operator training records must be in paper format and may not be maintained
electronically. - answer-False

T/F The two main types of corrosion protection on upgraded steel tanks are cathodic
protection and internal lining. - answer-True

As stated in the federal UST regulation, a spill or overflow of how many gallons that
results in a release of petroleum to the environment mist be reported to the
implementing agency? - answer-Greater than 25 Gallons

T/F For tanks installed after April 11, 2016 continuous in tank monitoring is an
allowable form of release detection. - answer-False

Document information

Uploaded on
November 9, 2024
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TOPDOCTOR
5.0
(1)
Sold
10
Followers
5
Items
3387
Last sold
1 year ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions