Missouri State Nursing Home Administrator Exam Questions With Answers Class 1 Deficiency - answerspresent eminent danger to health, safety, and welfare of resident. Corrected immediately Class 2 Deficiency - answersDirect or immediate relationship to health, safety, or welfare of resident-does not create imminent danger. When should Class 2 violation be corrected? - answersImmediately or prior to rein spection or according to time schedule in approved plan. How many Class 3 Violations have to occur for state to count? - answers5 Fire Resistant Construction specifications - answers2 hour fire resistant Maximum # of beds for each nursing unit - answers60 Maximum length between resident's room and nursing station and dirty utility area - answers140 ft How many isolation rooms needed in each nursing unit - answers2 What is the maximum number of residents allowed per bedroom - answers4 How many residents should be served by one tub or shower - answers15 Minimum width of corridors - answers8 ft Minimum width of stairways - answers44 in Minimum width of doorways through which residents pass - answers44 in Ceiling height - answers8 ft How water accessible to residents shall be between - answers105-120 How long should battery operated lights be set at - answers1 1/2 hours Hazardous areas shall be separated by construction of at least _____ of fire resistance rating - answers1 hour Oxygen in access of _____cubic ft should be stored in rooms with outside ventilation - answers1500 How many oxygen tanks for emergency use may be maintained in a readily accessible area - answers1 How many feet is the maximum travel distance from any point on the floor to a fire extinguisher - answers75 Fire extinguishers are checked ____ for pressure - answersmonthly Fire alarm system is tested _____ - answersmonthly Fire alarm is checked ______ by a _______ or _______ - answersyearly, fire alarm representative, or electrical contractor. How many unobstructed exits are necessary for each floor in the nursing home - answers2

Content preview

©JUSTTRACY EXAM SOLUTIONS

09/11/2024 10:50AM




Missouri State Nursing Home Administrator Exam
Questions With Answers

Class 1 Deficiency - answers✔✔present eminent danger to health, safety, and welfare of resident.
Corrected immediately



Class 2 Deficiency - answers✔✔Direct or immediate relationship to health, safety, or welfare of
resident-does not create imminent danger.



When should Class 2 violation be corrected? - answers✔✔Immediately or prior to rein spection or
according to time schedule in approved plan.



How many Class 3 Violations have to occur for state to count? - answers✔✔5



Fire Resistant Construction specifications - answers✔✔2 hour fire resistant



Maximum # of beds for each nursing unit - answers✔✔60



Maximum length between resident's room and nursing station and dirty utility area -
answers✔✔140 ft



How many isolation rooms needed in each nursing unit - answers✔✔2



What is the maximum number of residents allowed per bedroom - answers✔✔4



How many residents should be served by one tub or shower - answers✔✔15



Minimum width of corridors - answers✔✔8 ft



Minimum width of stairways - answers✔✔44 in

, ©JUSTTRACY EXAM SOLUTIONS

09/11/2024 10:50AM




Minimum width of doorways through which residents pass - answers✔✔44 in



Ceiling height - answers✔✔8 ft



How water accessible to residents shall be between - answers✔✔105-120



How long should battery operated lights be set at - answers✔✔1 1/2 hours



Hazardous areas shall be separated by construction of at least _____ of fire resistance rating -
answers✔✔1 hour



Oxygen in access of _____cubic ft should be stored in rooms with outside ventilation -
answers✔✔1500



How many oxygen tanks for emergency use may be maintained in a readily accessible area -
answers✔✔1



How many feet is the maximum travel distance from any point on the floor to a fire extinguisher -
answers✔✔75



Fire extinguishers are checked ____ for pressure - answers✔✔monthly



Fire alarm system is tested _____ - answers✔✔monthly



Fire alarm is checked ______ by a _______ or _______ - answers✔✔yearly, fire alarm
representative, or electrical contractor.



How many unobstructed exits are necessary for each floor in the nursing home - answers✔✔2

Document information

Uploaded on
November 9, 2024
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$9.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
1
Followers
0
Items
298
Last sold
1 year ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions