Personally Supervised - ANSWERSInspection, testing, servicing, and other maintenance of sprinkler systems must be -- whenever the building/structure is altered - ANSWERSWhen should required fire protection systems be extended or altered to maintain and continue protection? 6 - ANSWERSHow many extra sprinkler heads should be kept on the premises for prompt replacement of fused or damaged sprinklers? Any heads which have opened or been damaged - ANSWERSWhich types of sprinkler heads require replacement? 3 years - ANSWERSA detailed record of inspections, tests, and maintenance should be kept for at least -- Hydrostatic Pressure Test - ANSWERSTo demonstrate suitability for Fire Dept. use, connections to sprinkler systems shall be subject to a --- Master Fire Suppression Piping Contractor in the presence of a Fire Dept. representative. - ANSWERSA hydrostatic pressure test shall be arranged by the ----- the building owner or owner's representative - ANSWERSWho is responsible for hiring a Master Fire Suppression Piping Contractor? To maintain the sprinkler system & Determine the qualifications/competencies of the CoF Holder who performs the inspection, testing, and maintenance of the system. - ANSWERSWhat are the owner's responsibilities?

Show more Read less
Institution
Supervision Of Sprinkler Systems,
Course
Supervision of Sprinkler Systems,










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Supervision of Sprinkler Systems,
Course
Supervision of Sprinkler Systems,

Document information

Uploaded on
November 5, 2024
Number of pages
17
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Supervision of Sprinkler Systems, S-
12(100% Correct)

Personally Supervised - ANSWERSInspection, testing, servicing, and other maintenance of sprinkler
systems must be --



whenever the building/structure is altered - ANSWERSWhen should required fire protection systems be
extended or altered to maintain and continue protection?



6 - ANSWERSHow many extra sprinkler heads should be kept on the premises for prompt replacement of
fused or damaged sprinklers?



Any heads which have opened or been damaged - ANSWERSWhich types of sprinkler heads require
replacement?



3 years - ANSWERSA detailed record of inspections, tests, and maintenance should be kept for at least --



Hydrostatic Pressure Test - ANSWERSTo demonstrate suitability for Fire Dept. use, connections to
sprinkler systems shall be subject to a ---



Master Fire Suppression Piping Contractor in the presence of a Fire Dept. representative. - ANSWERSA
hydrostatic pressure test shall be arranged by the -----



the building owner or owner's representative - ANSWERSWho is responsible for hiring a Master Fire
Suppression Piping Contractor?



To maintain the sprinkler system & Determine the qualifications/competencies of the CoF Holder who
performs the inspection, testing, and maintenance of the system. - ANSWERSWhat are the owner's
responsibilities?

,Maintains records of all system inspections, tests, servicing, and other maintenance for the OOS
protection system. - ANSWERSImpairment Coordinator



The building owner shall assign an impairment coordinator when a fire protection system is OOS -
ANSWERSWho assigns an Impairment Coordinator?



When a fire protection system is scheduled to be placed out of service for inspection, testing, etc. & not
affecting more than 1 floor - ANSWERSPlanned Removal From Service

Sprinkler or Fire Alarm system is or will be OOS on more than one floor, The system needs to be out of
service longer than 8 hours, & One or more fire protection systems in the area will also be out of service
at the same time. - ANSWERSNotification of OOS conditions shall be made to Fire Dept. in the following
cases:



Report the defect to the owner. If it's not repaired within 30 days it shall be deemed an Impairment and
reported in writing to the Fire Dept. - ANSWERSWhat should a CoF Holder do if they observe a minor
defect not presenting a serious safety hazard?



Fire Dept. connections, System control valves, & Fire command center or a visible location in the building
lobby - ANSWERSOOS systems shall be identified by placing a tag at each of the following locations:



indicate which system or part thereof is out of service - ANSWERSImpairment Coordinators or building
owners shall ensure Tags are placed to--



A tag indicates a system,or portion, is OOS. Tags shall be placed at the main control valve and any closed
sectional valves serving areas affected - ANSWERSTag Requirement



The area affected, Description of condition, Occupancy Classification, CoF #, and Estimated time until
system is operational - ANSWERSWhat is indicated on each Tag?



Shall be posted on the tag indicating the static and flow pressures before and after the system was
placed OOS - ANSWERSDrain Test Results



The CoF Holder & Impairment Coordinator shall be made aware of and authorize placing the system OOS
- ANSWERSWho authorizes a Planned Removal From Service?

, Continuously patrol the out of service area, Be provided with an approved means of notification,
Immediately report fire, & Be trained in use of fire extinguishers - ANSWERSWhen a Fire Protection
System is OOS, Fire Watch personnel must:




Placed on the main control valve if no impairment is found in the entire system - ANSWERSGreen Tag



A system is Fully OOS - ANSWERSWhat does a White Disc indicate?



Placed at main control valve & Indicates the company name, date of removal from service,and
anticipated return to service date - ANSWERSRed Tag - Fully Out of Service System:



A system is Partially OOS - ANSWERSWhat does a Blue Disc indicate?



Glycerin not greater than 48% and Propylene Glycol not greater than 38% nonfreezing solution -
ANSWERSApproved nonfreezing solutions include --



All parts of an automatic system exposed to freezing temps shall be protected from freezing via a Dry
Pipe System or system with nonfreezing, noncombustible solutions. - ANSWERSProtection of Sprinkler
Systems



The Health Dept and Bureau of Water Supply of the Dept of Environmental Protection. A backflow
preventer may be required. - ANSWERSWhen a system filled with nonfreezing solution is connected to a
potable (drinking) water supply, it shall be subject to requirements of:



Water supply conditions, Gravity and pressure tanks and levels therein, Valves, Risers, Piping, Sprinkler
heads and Fire Department connections, Alarms, Fire, Booster and special service pumps, Obstructions,
etc. - ANSWERSA Detailed Inspection Record notes any defects and information relative to:



Dates of inspection, CoF #, and CoF signature - ANSWERSWhat information is indicated on an approved
Riser Card?

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
papersmaster01 Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
277
Member since
2 year
Number of followers
106
Documents
14015
Last sold
23 hours ago
PAPERSMASTER01

On this page you will find documents , package deals, flashcards offered by seller PAPERSMASTER01.With our documents on your side you"ll be well equipped to tackle you exams and achieve the grades you need.

3.9

71 reviews

5
22
4
33
3
9
2
3
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions