fire department connection - ANSWERSnormally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. system control valve - ANSWERSvalve controlling flow to water-based fire protection systems. fire command center - ANSWERS... MFSPC - ANSWERS... MLP - ANSWERS... tags - ANSWERSon closed section valves serving affected areas: area affected, brief description, occupancy classification, c of f number, estimated time until operational Green tag - ANSWERSno impairment found in entire system- main control valve white tag - ANSWERSfully out of service- place on all fire department connecitons red tag - ANSWERSplace on main control valve if FULLY OR PARTIALLY out of service... put sprinkler company name, date of removal from service and anticipated time to operational blue disk - ANSWERSpartially out of service- on all fire department connections water storage tank - ANSWERS... OS & Y valve - ANSWERSindicating type of control valve used for fire sprinkler system

Content preview

S12 sprinkler test 100% Correct!!

fire department connection - ANSWERSnormally on exterior of building... FDNY can pump supplemental
water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to
supplement existing water supplies.



system control valve - ANSWERSvalve controlling flow to water-based fire protection systems.



fire command center - ANSWERS...



MFSPC - ANSWERS...



MLP - ANSWERS...



tags - ANSWERSon closed section valves serving affected areas: area affected, brief description,
occupancy classification, c of f number, estimated time until operational



Green tag - ANSWERSno impairment found in entire system- main control valve



white tag - ANSWERSfully out of service- place on all fire department connecitons



red tag - ANSWERSplace on main control valve if FULLY OR PARTIALLY out of service... put sprinkler
company name, date of removal from service and anticipated time to operational



blue disk - ANSWERSpartially out of service- on all fire department connections



water storage tank - ANSWERS...



OS & Y valve - ANSWERSindicating type of control valve used for fire sprinkler system

, deluge valve - ANSWERSwater supply control valve intended to be operated by actuation of an automatic
detection system that is installed in the same area as the discharge devices. INTENDED USE IS MANUAL
AND AUTO



deluge sprinkler system - ANSWERSemploying open sprinklers that are attached to a piping system that
is connected to a water supply through a valve that is opened by the operation of a detection system
installed in the same areas as the sprinklers. WHEN IT OPENS, water flows into the piping system and
discharges from all sprinklers attached.



Early suppresion fast response sprinklers - ANSWERSfast response sprinkler that is listed for its capability
to provide fire suppression of specific high challenge fire hazards



extra large orifice sprinklers - ANSWERS= or > 1 inch less pressure to achieve a given discharge density



extended coverage sprinkler - ANSWERS400 max square feet discharge



fire pump - ANSWERSa provider of liquid flow and pressure dedicated to fire protection. A fire pump is a
part of a fire sprinklers system water supply and can be powered by electric, diesel or steam. connected
to public water source or tank. provides higher pressure to sprinkler system

impairment coordinator - ANSWERSin charge of safety during out of service systems



intermediate level sprinkler - ANSWERSsprinkler equipped with integral shields to protect the operating
elemtn form discharge from sprinklers installed at higher elevations



large orifice sprinkler - ANSWERSsprinkler head with orifice size equal or greater than 3/4 and less than 1
inch



listed device - ANSWERSA fire protection component that has been tested to perform under parameters
specified for its use by a nationally recognized testing agency. Underwriter's Laboratory (UL) and Factory
Mutual (FM) are the two most common.

Document information

Uploaded on
November 5, 2024
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
papersmaster01
3.9
(73)
Sold
302
Followers
106
Items
14701
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions