Sonographers should be aware of work-related musculoskeletal disorders. Best practice while scanning is to avoid abducting the arm more than how many degrees? a. 50 b. 90 c. 30 d. 40 -Correct Answer c. 30 Which action demonstrates best practice during ultrasound exams regarding the ALARA principle? a. The exposure time should be extended during the exam. b. use the lowest possible output power that provides a diagnostic image. c. use the lowest possible gain. d. Ensure that the time gain compensation (TGC is within acceptable limits. -Correct Answer b. use the lowest possible output power that provides a diagnostic image Which type of cavitation is the most concerning cause of bioeffects? a. Transient b. Absorption c. Stable d. Thermal -Correct Answer a. transient Assuming an unfocused ultrasound beam, the American Institute of ultrasound in Medicine's "statement on Mammalian Biological Effects of ultrasound In vivo" has confirmed that no bioeffects have been noted when the spatial pulse temporal average (SPTA) intensity is less than which value? a. 1 mW/cm2 b. 100 W/cm2 c. 1 W/cm2 d. 100 mW/cm2 -Correct Answer d. 100 mW/cm2 A sonographer notices that the mechanical index (MI) is too high during an ultrasound. What would be the MOST appropriate modification that the sonographer can make? a. decrease receiver gain b. increase period c. decrease the output power d. decrease the frequency of the transducer -Correct Answer c. decrease the output power Select the technique that will generate the LEAST amount of exposure to the patient. a. Spectral Doppler b. Color flow Doppler c. Grayscale d. M-mode -Correct Answer c. grayscale When a vibrating string or fluid pump is used to test system performance, what parameter is being tested? a. Dead zone b. Doppler velocities c. Contrast resolution d. Grayscale sensitivity -Correct Answer b. Doppler velocities A tissue-equivalent phantom is used to ensure the efficiency of the ultrasound machine. Choose the resolution that is NOT tested with this phantom. a. Temporal b. Contrast c. Axial d. Horizontal -Correct Answer a. temporal Which performance check describes the ability of the ultrasound machine to correctly visualize signals that are weaker than others? a. Accuracy b. Specificity c. Reliability d. Sensitivity -Correct Answer d. sensitivity What is the name of the recent technological advancement that is used on tissues such as the liver, breast, prostate, and thyroid to assess the stiffness of tissue or to better assess lesions? a. Contrast-enhanced ultrasound b. Fusion imaging c. Elastography d. Harmonics -Correct Answer c. elastography Which choice is NOT a true statement regarding this filling defect within the gallbladder? a. The filling defect displays a significant amount of attenuation. b. it has created an enhancement artifact. c. It has created a shadowing artifact d. Regions deeper than the filling defect are obscured. -Correct Answer b. it has created an enhancement artifact Which type of artifact appears echogenic and stems from gas bubbles as they vibrate due to the interaction with the ultrasound beam? a. Ring-down artifact b. edge shadow c. Crosstalk d. Slice thickness -Correct Answer a. ring-down artifact

Content preview

ARDMS Abdomen Exam



ARDMS practice test questions and
answers 2024-2025
Sonographers should be aware of work-related musculoskeletal disorders. Best practice
while scanning is to avoid abducting the arm more than how many degrees?
a. 50
b. 90
c. 30
d. 40 -Correct Answer ✔c. 30

Which action demonstrates best practice during ultrasound exams regarding the ALARA
principle?
a. The exposure time should be extended during the exam.
b. use the lowest possible output power that provides a diagnostic image.
c. use the lowest possible gain.
d. Ensure that the time gain compensation (TGC is within acceptable limits. -Correct
Answer ✔b. use the lowest possible output power that provides a diagnostic image

Which type of cavitation is the most concerning cause of bioeffects?
a. Transient
b. Absorption
c. Stable
d. Thermal -Correct Answer ✔a. transient

Assuming an unfocused ultrasound beam, the American Institute of ultrasound in
Medicine's "statement on Mammalian Biological Effects of ultrasound In vivo" has
confirmed that no bioeffects have been noted when the spatial pulse temporal average
(SPTA) intensity is less than which value?
a. 1 mW/cm2
b. 100 W/cm2
c. 1 W/cm2
d. 100 mW/cm2 -Correct Answer ✔d. 100 mW/cm2

A sonographer notices that the mechanical index (MI) is too high during an ultrasound.
What would be the MOST appropriate modification that the sonographer can make?
a. decrease receiver gain
b. increase period
c. decrease the output power
d. decrease the frequency of the transducer -Correct Answer ✔c. decrease the output
power

Select the technique that will generate the LEAST amount of exposure to the
patient.
a. Spectral Doppler


ARDMS Abdomen Exam

,ARDMS Abdomen Exam


b. Color flow Doppler
c. Grayscale
d. M-mode -Correct Answer ✔c. grayscale

When a vibrating string or fluid pump is used to test system performance,
what parameter is being tested?
a. Dead zone
b. Doppler velocities
c. Contrast resolution
d. Grayscale sensitivity -Correct Answer ✔b. Doppler velocities

A tissue-equivalent phantom is used to ensure the efficiency of the
ultrasound machine. Choose the resolution that is NOT tested with this
phantom.
a. Temporal
b. Contrast
c. Axial
d. Horizontal -Correct Answer ✔a. temporal

Which performance check describes the ability of the ultrasound machine
to correctly visualize signals that are weaker than others?
a. Accuracy
b. Specificity
c. Reliability
d. Sensitivity -Correct Answer ✔d. sensitivity

What is the name of the recent technological advancement that is used on tissues such
as the liver, breast, prostate, and thyroid to assess the stiffness of tissue or to better
assess lesions?
a. Contrast-enhanced ultrasound
b. Fusion imaging
c. Elastography
d. Harmonics -Correct Answer ✔c. elastography

Which choice is NOT a true statement regarding this filling defect within the gallbladder?
a. The filling defect displays a significant amount of attenuation.
b. it has created an enhancement artifact.
c. It has created a shadowing artifact
d. Regions deeper than the filling defect are obscured. -Correct Answer ✔b. it has
created an enhancement artifact

Which type of artifact appears echogenic and stems from gas bubbles as they vibrate
due to the interaction with the ultrasound beam?
a. Ring-down artifact
b. edge shadow
c. Crosstalk

ARDMS Abdomen Exam

, ARDMS Abdomen Exam


d. Slice thickness -Correct Answer ✔a. ring-down artifact

What is the fundamental reason that the power and intensity of the ultrasound beam
diminish as it travels through tissue?
a. Absorption
b. Cavitation
c. Obstruction
d. Acoustic impedance -Correct Answer ✔a. absorption

Select the modification that the sonographer can make to decrease the amount of
attenuation as the ultrasound beam travels through tissues.
a. Increase the imaging depth.
b. Increase the frequency of the transducer.
c. Decrease the output power.
d. Decrease the frequency of the transducer. -Correct Answer ✔d. decrease the
frequency of the transducer

Choose the ultrasound system function that enables the sonographer to
adapt to the amount of attenuation that occurs with increasing depth.
a. Focusing
b. Receiver gain
c. TGC
d. Output power -Correct Answer ✔c. TGC

Assume that a sound beam is traveling in soft tissue. Calculate the
attenuation coefficient if the frequency is 12 MHz.
a. 12dB/cm
b. 6 dB/cm
c. 8 dB/cm
d. 10 dB/cm -Correct Answer ✔b. 6 dB/cm

What is NOT a component of attenuation?
a. Reflection
b. Scattering
c. Resolution
d. Absorption -Correct Answer ✔c. resolution

Impedance is NOT influenced by which component?
a. The frequency of the transducer
b. Density
c. Propagation speed
d. Stiffness -Correct Answer ✔a. the frequency of the transducer

For reflection to take place, which situation must exist?
a. The border of two different tissues must have different impedances.


ARDMS Abdomen Exam

Document information

Uploaded on
November 1, 2024
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$15.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PossibleA
3.9
(151)
Sold
1072
Followers
651
Items
13988
Last sold
1 day ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions