Prep/ Latest Update
PCI-X - CORRECT ANSWERS -Only expansion slot allows backward compatibility with
traditional PCI cards
Socket/LGA775 - CORRECT ANSWERS -Socket T used in systems we've rebuilt in
labs that resides in Cabinet 1
AMD (Advanced Micro Devices) - CORRECT ANSWERS -Company that makes Duron,
Athlon, phenom and Opteron
24 - CORRECT ANSWERS -Number of pins in main power connector for a server
motherboard
plug and play - Modern expansion buses that support self-configuration - CORRECT
ANSWERS -
x1 - CORRECT ANSWERS -How to describe shortest PCIe slot used in modern
motherboards
480 Mbps - CORRECT ANSWERS -Maximum theoretical data transfer rate of USB 2.0
6 Gb/s - CORRECT ANSWERS -Max transfer rate of third gen of SATA
5 Gb/s - CORRECT ANSWERS -Max transfer rate of USB 3.0
20Gb/s - CORRECT ANSWERS -Max transfer rate of Thunderbolt 2
32 bits - CORRECT ANSWERS -Bus width of traditional PCI expansion bus
64 bits - CORRECT ANSWERS -Bus width of PCI-X expansion bus
33 MHz - CORRECT ANSWERS -Standard speed of PCI expansion bus
Wide SCSI - CORRECT ANSWERS -Type of parallel SCSI cable has pins on cable
connector rather than on device connector
1 - CORRECT ANSWERS -Parity bit used by parity memory when data transferred is
10110001 and it's using odd parity
Narrow SCSI - CORRECT ANSWERS -Type of parallel SCSI used a 50-pin ribbon
connector to connect internal devices to the host adaptor
,Termination - CORRECT ANSWERS -Must be installed or configured on both physical
ends of a parallel SCSI bus
SuperSpeed - CORRECT ANSWERS -3gbps transfer rate used by USB 3.0
ECC / Buffered Registered - CORRECT ANSWERS -2 types of memory used by
servers
19 inches - CORRECT ANSWERS -Width of standard server rack
PCI - CORRECT ANSWERS -Parallel 32 bit bus used for past 2 decades
Zero Insertion Force Socket (ZIF) - CORRECT ANSWERS -PGA socket with lever
PCI express (PCIe) - CORRECT ANSWERS -Expansion bus transfers data in serial
form, common internal expansion bus
Blade Server Enclosure - CORRECT ANSWERS -Name of modular rack mounted
enclosure that allows to add more servers
Height of 5 u server chassis - CORRECT ANSWERS -8.75 inches
Headless - CORRECT ANSWERS -Term used to describe server with no connected
monitor
Xeon - CORRECT ANSWERS -Most common server class intel processor line
redundant power supply - CORRECT ANSWERS -Name of fault tolerant power supply
found in server
Micro USB - CORRECT ANSWERS -Name of USB connector found on smartphones
that don't use USB C connector
hyper threading - CORRECT ANSWERS -Feature used by many intel desktop
processors that appears to have twice as many cores
sound card capabilities - CORRECT ANSWERS -Something integrated in motherboard
but not on server motherboard
KVM switch - CORRECT ANSWERS -Something that physically connects servers to a
single monitor, mouse or keyboard
IEEE 1394 - CORRECT ANSWERS -Official name for firewire
LGA (Lan Grid Array) - CORRECT ANSWERS -Type of socket that has pins in socket
rather than processor
, Mini DisplayPort - CORRECT ANSWERS -Name of port used by first 2 generations of
Thunderbolt
2800 MHz - CORRECT ANSWERS -If processor is rated at 2.8 GHz its roughly how
many MHz
22.5 Gb/s - CORRECT ANSWERS -Max speed of current SAS interface standard
Do nothing - CORRECT ANSWERS -How to configure termination of SAS device
60 Hz - CORRECT ANSWERS -Most common frequency /refresh of typical LCD
monitor
1 - CORRECT ANSWERS -Parity bit used by parity memory when data is transferred
11001110 and it's using even parity
Result when u XOR the following values: 1011, 0101 - CORRECT ANSWERS -1110
RAID 0 - CORRECT ANSWERS -Level of raid provides no fault tolerance
800 MHz - CORRECT ANSWERS -Effective bus speed of DDR2 known as PC-6400
3.4 GHz - CORRECT ANSWERS -Resulting speed of processor of 200MHz base clock
speed and 17x multiplier
Both parity memory and ECC memory use parity bit to detect single bit errors, this is
how they react differently - CORRECT ANSWERS -parity memory request data to be
resent, whereas ECC fixes it on the fly
SCSI IDs - CORRECT ANSWERS -This is how parallel SCIS differentiates between
devices connected to it
RAID - CORRECT ANSWERS -ALL SAS cards have this additional capability built into
them
ID7 - CORRECT ANSWERS -SCIS ID that should be assigned to parallel
SAS - CORRECT ANSWERS -Parallel SCSI is being phased out in favor of this
Ways to configure termination on parallel SCSI bus - CORRECT ANSWERS -Jumper,
switch, resistor pack, SCSI bus, SCAM/auto-termination
Peer to peer - CORRECT ANSWERS -USB considered host based, firewire is
considered this (non-host based)