u_________ are necessary for complete combustion - time, temperature, mixture, and atomization
if the steam pressure gauge indicates 200 PSIG, the absolute pressure is______ - 214.7
a boiler is operating at 400 PSI, and the safety valve opens at 410 PSI and closes at 398 PSI. The
blowdown is______psi - 12
an oil cooler is commonly used with a(n) ________ when operating in conjunction with a turbo-
generator - steam turbine
a boiler is producing 40,000lb of steam/hr at a pressure of 100 PSI and a steam temperature of 500
degrees Fahrenheit. The steam produced is _______ steam - superheated
the economizer on a boiler is used to _______ - add heat to the feed water
blowers are normally used with________ boilers - water tube
overheating of tubes on a boiler can be caused by________ - scale on tubes
carbon dioxide in a condensate return system causes_________ - channeling
a ________ pump is a positive displacement pump - reciprocating
a boiler generating 6000 lb of steam/hr produces _______btu/hr - 6,000,000
, a bottom blowdown is performed on a boiler to _____ - discharge sludge and sediment
water columns are connected to the boiler with a minimum of _______" pipe - 1
the minimum size of a water column blowdown valve is_______". - 3/4
the maximum size bottom blowdown valve on a boiler is_________". - 2 1/2
a ________ allows condensate to pass through, but stops Steam. - a steam trap
when taking over a shift, the first thing to do is check the________ - water level in each boiler
according to the asme code, a high-pressure boiler having more than 500 square feet of heating surface
shall have________ - two or more safety valves
the probable cause of an increase in temperature of gases of combustion at the boiler Outlet is____ -
dirty heating services
boilers in battery equipped with________ must have two main steam stop valves and a free-flowing
drain between them - manhole openings
in order to be sure the gauge glass is indicating an accurate water level reading, the stationary engineer
should______ - blowdown the gauge glass
a continuous blowdown line is located___ - in the Steam and water drum well below the nowl
a temperature reading of 80 degrees Celsius is equal to_________°f - 176
ENGINEER LICENSE PREP QUESTIONS
WITH COMPLETE SOLUTION
u_________ are necessary for complete combustion - time, temperature, mixture, and atomization
if the steam pressure gauge indicates 200 PSIG, the absolute pressure is______ - 214.7
a boiler is operating at 400 PSI, and the safety valve opens at 410 PSI and closes at 398 PSI. The
blowdown is______psi - 12
an oil cooler is commonly used with a(n) ________ when operating in conjunction with a turbo-
generator - steam turbine
a boiler is producing 40,000lb of steam/hr at a pressure of 100 PSI and a steam temperature of 500
degrees Fahrenheit. The steam produced is _______ steam - superheated
the economizer on a boiler is used to _______ - add heat to the feed water
blowers are normally used with________ boilers - water tube
overheating of tubes on a boiler can be caused by________ - scale on tubes
carbon dioxide in a condensate return system causes_________ - channeling
a ________ pump is a positive displacement pump - reciprocating
a boiler generating 6000 lb of steam/hr produces _______btu/hr - 6,000,000
, a bottom blowdown is performed on a boiler to _____ - discharge sludge and sediment
water columns are connected to the boiler with a minimum of _______" pipe - 1
the minimum size of a water column blowdown valve is_______". - 3/4
the maximum size bottom blowdown valve on a boiler is_________". - 2 1/2
a ________ allows condensate to pass through, but stops Steam. - a steam trap
when taking over a shift, the first thing to do is check the________ - water level in each boiler
according to the asme code, a high-pressure boiler having more than 500 square feet of heating surface
shall have________ - two or more safety valves
the probable cause of an increase in temperature of gases of combustion at the boiler Outlet is____ -
dirty heating services
boilers in battery equipped with________ must have two main steam stop valves and a free-flowing
drain between them - manhole openings
in order to be sure the gauge glass is indicating an accurate water level reading, the stationary engineer
should______ - blowdown the gauge glass
a continuous blowdown line is located___ - in the Steam and water drum well below the nowl
a temperature reading of 80 degrees Celsius is equal to_________°f - 176