Fluoroscopy exam Questions and Answers- Updated 2024 Total filtration permanently required in the useful fluoroscopic beam should not be less than - Answer-2.5mm Aluminum If X-ray source is below the table, useful beam exposure must be measured at what distance above the table top - Answer-30 cm Table top exposure rates for units without auto exposure control must be measured every - Answer-3 years Dark adaptation for the eye takes how long - Answer-30 minutes Target-to-tabletop distance must be greater than and should be greater than... - Answer-12 and 18 inches Integration time for brain to recognize an object - Answer-0.2 seconds Most scatter occurs at which direction from the primary beam - Answer-135 degrees mA setting for spot filming where a spot film camera is not used - Answer-150 mA Greatest dose to the patient comes from spot filming cameras using this film size - Answer- 105 mm EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 2/16 SI unit analogous to the rad is - Answer-Gray _________ is a variation in density resulting from the random spatial distribution of quanta. - Answer-Quantum sink SI unit analogous to the rem - Answer-Sievert (unit) Exposure reduction of .25 mm lead - Answer-97% Scattered radiation received is proportional to - Answer-Dose received by the patient Most effective medium for static viewing in terms of reducing patient dose - Answer-Video disc recorder Contrast of the image intensifying tube is measured by - Answer-conversion factor maximum magnification for cinefluorography is done via which method - Answer-total over framing Ratio of photons that leave the output phosphor to the number of Xray photons that strike the input phosphor - Answer-Flux gain Half value layer determines which characteristic of the Xray - Answer-Xray quality Ability to distinguish separate objects in line pairs per mm - Answer-Resolving power The portion of the image intensifier responsible for magnification - Answer-electrostatic lenses resolution of a 9 inch image intensifier tube - Answer-3.5 line pairs per millimeter EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 3/16 light photons intercepting when electrons strike a fluorescent screen forms a... - Answer- Real image Fluoro with a grid in place affects exposure rates how - Answer-1.5-2 x higher Greatest radiosensitivity of fetus occurs when - Answer-2-8 weeks gestation The quantity of the beam is controlled by which unit of measurement - Answer- miliamperage Which fluoroscopic method gives patient dose reduction of up to to 95%? - Answer-video disc recorder 100erg/gram is equivalent to? - Answer-1 rad Fluoro units with AECs or CINE cameras must have physicist calibration how often - Answer- every year Which imaging modality has the best resolution - Answer-Radiograph Compared to the input phosphor, the image output phosphor is... - Answer-Smaller and brighter As spot film size increases, what happens to the patient dose? - Answer-Patient dose increases Unit used to specify the quality of an X-ray beam - Answer-HVL

Show more Read less
Institution
Fluoroscopy
Course
Fluoroscopy










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Fluoroscopy
Course
Fluoroscopy

Document information

Uploaded on
October 16, 2024
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024




Fluoroscopy exam Questions and
Answers- Updated 2024

Total filtration permanently required in the useful fluoroscopic beam should not be less than -

Answer✔✔-2.5mm Aluminum


If X-ray source is below the table, useful beam exposure must be measured at what distance

above the table top - Answer✔✔-30 cm


Table top exposure rates for units without auto exposure control must be measured every -

Answer✔✔-3 years


Dark adaptation for the eye takes how long - Answer✔✔-30 minutes


Target-to-tabletop distance must be greater than and should be greater than... - Answer✔✔-12

and 18 inches


Integration time for brain to recognize an object - Answer✔✔-0.2 seconds


Most scatter occurs at which direction from the primary beam - Answer✔✔-135 degrees


mA setting for spot filming where a spot film camera is not used - Answer✔✔-150 mA


Greatest dose to the patient comes from spot filming cameras using this film size - Answer✔✔-

105 mm


Page 1/16

,EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


SI unit analogous to the rad is - Answer✔✔-Gray


_________ is a variation in density resulting from the random spatial distribution of quanta. -

Answer✔✔-Quantum sink


SI unit analogous to the rem - Answer✔✔-Sievert (unit)


Exposure reduction of .25 mm lead - Answer✔✔-97%


Scattered radiation received is proportional to - Answer✔✔-Dose received by the patient


Most effective medium for static viewing in terms of reducing patient dose - Answer✔✔-Video

disc recorder


Contrast of the image intensifying tube is measured by - Answer✔✔-conversion factor


maximum magnification for cinefluorography is done via which method - Answer✔✔-total over

framing


Ratio of photons that leave the output phosphor to the number of Xray photons that strike the

input phosphor - Answer✔✔-Flux gain


Half value layer determines which characteristic of the Xray - Answer✔✔-Xray quality


Ability to distinguish separate objects in line pairs per mm - Answer✔✔-Resolving power


The portion of the image intensifier responsible for magnification - Answer✔✔-electrostatic

lenses


resolution of a 9 inch image intensifier tube - Answer✔✔-3.5 line pairs per millimeter

Page 2/16

, EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


light photons intercepting when electrons strike a fluorescent screen forms a... - Answer✔✔-

Real image


Fluoro with a grid in place affects exposure rates how - Answer✔✔-1.5-2 x higher


Greatest radiosensitivity of fetus occurs when - Answer✔✔-2-8 weeks gestation


The quantity of the beam is controlled by which unit of measurement - Answer✔✔-

miliamperage


Which fluoroscopic method gives patient dose reduction of up to to 95%? - Answer✔✔-video

disc recorder


100erg/gram is equivalent to? - Answer✔✔-1 rad


Fluoro units with AECs or CINE cameras must have physicist calibration how often - Answer✔✔-

every year


Which imaging modality has the best resolution - Answer✔✔-Radiograph


Compared to the input phosphor, the image output phosphor is... - Answer✔✔-Smaller and

brighter


As spot film size increases, what happens to the patient dose? - Answer✔✔-Patient dose

increases


Unit used to specify the quality of an X-ray beam - Answer✔✔-HVL


cycles per time unit in a TV camera is known as... - Answer✔✔-bandwidth

Page 3/16

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Emillect West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
28
Member since
1 year
Number of followers
2
Documents
3004
Last sold
1 month ago
GOLDEN ORCHIDS STORE.

On this page, you find all documents, package deals, and flashcards offered by seller Emillect.

3.0

4 reviews

5
1
4
0
3
2
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions