Quality Control Exam Questions with 100%
Verified Answers
The ability of a radiographic unit to produce a constant radiation output for
various combinations of mA and exposure time is called.? - ✔️✔️Exposure linearity


Exposure linearity is determined by a..?
This measures radiation intensity at various combinations of mA and exposure
time
Exposure linearity must be within..?
This test should be evaluated annually or whenever any change or repair of
operating console or generator occurs - ✔️✔️Precision radiation dosimeter
10% for mA station


If, when using any combination of kVp, mA and exposure time, the RT decides to
change on factor and then return to the previous value of radiation exposure, the
previous value should be precisely the same, this is known as?
2 methods used to evaluate this both use a radiation dosimeter, and
mathematical formulas can be used to determine this in both cases

Output radiation intensity should not bary by more than..? - ✔️✔️Exposure
reproducibility
5%


Require periodic attention to minimize appearance of artifacts
-Localized lack of sharpness on radiographs
Screens cleaned with soft, lint-free cloth and cleaning solution
How often depends on workload of department

, Not less than every other month - ✔️✔️Intensifying screens


Aprons, gloves, and gonadal shielding should be radiography or fluoroscopy..? for
defects

Cracks, tear, or holes require replacement of apparel - ✔️✔️Annually


Filmbox illuminators should be photometrically analyzed..?
Used to measure light intensity at several areas of illuminator?
Intensity should be at least?
Should not vary more than..? over surface of illuminator
All bulbs should match and be replaced at same time so that the lightning is even
- ✔️✔️Annually
Photometers
1500 cd/m^2
10%


Exposure rate-Federal law and most states require that ESE (entrance skin
exposure) shall not exceed..?
For interventional fluoro may be equipped with a high level control

This allows an ESE up to..? - ✔️✔️10R/min (100mGy/min
20R/min (200mGy/min)


Measurements of fluoro are made with calibrated radiation..?
This ensures that these levels are not exceeded

Document information

Uploaded on
October 8, 2024
Number of pages
15
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Examcheatcode
5.0
(1)
Sold
4
Followers
1
Items
1223
Last sold
1 year ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions