Alternating Current (AC) always flows one way then the other? - Answer True. AC always flows one way then the other. The frequency of AC is measured in? - Answer Measured in hertz Hz What refers to a voltage can convey information? - Answer Electrical Signal What refers to the maximum voltage that can be reached by a signal? - Answer Amplitude Electricity may flow only when? - Answer There has to be a for it to return making a complete circuit What is the return path for electrical power to flow back to the service panel? - Answer Neutral The live wire is always ungrounded? - Answer True. They are very hot caring electrical power A ground electrode conductor originates at the neutral or equipment ground bus of the service panel? - Answer True A ground electrode should not be made in contact with the earth? - Answer False. sound be on contact with the earth Compare Watts with Voltage - Answer Watts are the measure of power. Voltage is the measure of potential energy. You should size conductors no less ______ of the continuous loads plus _________ of the non-continuous loads,. - Answer 125% / 100%

Aperçu du contenu

Arizona Contractor License CR-67 Prep
Exam And Correct Answers.
Alternating Current (AC) always flows one way then the other? - Answer True. AC always flows one way
then the other.



The frequency of AC is measured in? - Answer Measured in hertz Hz



What refers to a voltage can convey information? - Answer Electrical Signal



What refers to the maximum voltage that can be reached by a signal? - Answer Amplitude



Electricity may flow only when? - Answer There has to be a for it to return making a complete circuit



What is the return path for electrical power to flow back to the service panel? - Answer Neutral



The live wire is always ungrounded? - Answer True. They are very hot caring electrical power



A ground electrode conductor originates at the neutral or equipment ground bus of the service panel? -
Answer True



A ground electrode should not be made in contact with the earth? - Answer False. sound be on contact
with the earth



Compare Watts with Voltage - Answer Watts are the measure of power. Voltage is the measure of
potential energy.



You should size conductors no less ______ of the continuous loads plus _________ of the non-
continuous loads,. - Answer 125% / 100%

,Conductor sizes are often expressed in? - Answer American Wire Gage (AWG)



What refers to the allowable current-carrying capacity of a conductor? - Answer Ampacity



The insulation type determines the areas the writers can and cannot used? - Answer True



RHH wires use rubber insulation that is high heat resistant and is good in? - Answer Is only good in dry
locations.



RHW-2 wires use the rubber insulation but are suitable for wet locations? - Answer True



What cables can be used inside wall, ceiling or under the floor. - Answer Non-metallic (NM)



What cables are most appropriate for damp areas? - Answer Underground feeder (UF) or Non-metallic
Wet underground (NMWU)



THWN means? - Answer Flame retardant, Heat resistant, Moisture resistant, Gasoline resistant, and oil
resistant.



An insulated grounded conductor which is ____ AWG or below should be identified by a continuous
white or gray outer finish. - Answer 6 AWG



What is the amount of voltage measured between any two line conductors of a balanced three-phase
system. - Answer Line voltage



What describes the voltage measured across any one component of a balanced three-phase system. -
Answer Phase Voltage



A _______ is unintentional mess up. - Answer Ground Fault

, An effective Ground-Fault current path is? - Answer An effective Ground-Fault current paths a path
intentionally constructed to facilitate the operation of the overcurrent protective devices currently in
place.



GFCI is never sensitive to small "leaks" of current - Answer False. GFCI = ground-fault circuit interrupter



Grounding and bonding means exactly the same thing? - Answer False. Bonding is a means of allowing
electrical continuity between metallic objects.



A typical work space (for a working voltage under 600V) should have a minimum headroom of ______ m.
- Answer 2.0 m



typically there are ____ hot wires running from the utility company into the service panel. - Answer 2



A service disconnect need to have a rating which is? - Answer No less than that the calculated load or
for the type of installation



Fast- blow fuses tend to open real quick when the rated current is reached. - Answer True



System grounding is required when you have a supply transformer of a SOV or lower system? - Answer
System grounding is required when you have a supply transformer of a 50V or lower system which itself
is supplied from a source over 150V to the ground



On a class 1 circuit it is ok to use smaller wire sizes than normal power circuits such as. - Answer
Anything 16 AWG or lower



Class 1 signaling and remote control circuits are limited too? - Answer 600 Volts



When a circuit controls equipment can introduce a direct life safety hazard, the circuit has to be? -
Answer Class 1



Class 2 circuit must be kept separate from lighting? - Answer True

Infos sur le Document

Publié le
8 octobre 2024
Nombre de pages
16
Écrit en
2024/2025
Type
Examen
Contient
Questions et réponses
$10.59

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
COCOSOLUTIONS
4.1
(39)
Vendu
236
Abonnés
16
Éléments
9903
Dernière vente
2 jours de cela




Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Vous travaillez sur vos références ?

Créez des citations précises en APA, MLA et Harvard avec notre générateur de sources gratuit.

Vous travaillez sur vos références ?

Foire aux questions