BICSI - Installer 1 - Review Exam With Complete Solution
B
A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed
______?
A 5 m (16.5')
B 10 m (33')
C 15 m (50')
D 30 m (100')
C
Which of the following is a property of an electromagnetic field built around a conductor
that opposes any changes in current flow in a circuit?
A Impedance
B Capacitance
C Inductance
D Resistance
Previous
Play
Next
Rewind 10 seconds
Move forward 10 seconds
Unmute
,0:01
/
0:15
Full screen
Brainpower
Read More
A
Which of the following markings is applied for non-conductive optical fiber
general-purpose cables?
A OFNG
B OFCR
C OFCP
D OFNP
A
Which of the following most accurately defines a collection of rules put out by a
governmental authority at the state level in the US?
A Regulations
B Best Practices
C Applications
D Guidelines
B
What is the Category 6 cable performance designation?
A 100 MHz
B 250 MHz
C 500 MHz
D 600 MHz
A
Which one of the following types of optical fibre cable should be colour coded with an
,Orange outer cable sheath?
A MM with a 100 um core diameter
B Dispersion-shifted SM optical fibre
C Polarization maintain SM optical fibre
D SM optical fibre
D
What is the major advantage in using wall-mounted racks and cabinets instead of
making use of traditional equipment racks?
A Provides the equipment with a much higher level of protection
B Makes it easier to rearrange the equipment
C Provides the best airflow around equipment in the equipment room
D Uses less equipment room space
C
Which topology is based on a linear design where all devices on the network are
connected on a single piece of cable?
A Star
B Ring
, C Bus
D
Which Two organizations have been responsible for the standardized coordination of
telecommunications cabling on a global level?
A Alliance for Telecommunications Industry Solutions (ATIS) and Society for Cable
Telecommunications Engineers (SCTE)
B National Electrical Contractors Association (NECA) and National Fire Protection
Association (NFPA)
C Comite Europeen de Normalisation Electrotechnique (CENELEC) and Electronic
Industries Association (EIA)
D International Organization for Standardization (ISO) and International
Electrotechnical Commission (IEC)
B
Which one of the following is designed to provide protection from injurious chemicals?
A Slash-resistant gloves
B Rubber gloves
C Leather gloves
B
Which one of the following is a building-serving space that contains big pieces of
common active equipment?
A TR
B
A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed
______?
A 5 m (16.5')
B 10 m (33')
C 15 m (50')
D 30 m (100')
C
Which of the following is a property of an electromagnetic field built around a conductor
that opposes any changes in current flow in a circuit?
A Impedance
B Capacitance
C Inductance
D Resistance
Previous
Play
Next
Rewind 10 seconds
Move forward 10 seconds
Unmute
,0:01
/
0:15
Full screen
Brainpower
Read More
A
Which of the following markings is applied for non-conductive optical fiber
general-purpose cables?
A OFNG
B OFCR
C OFCP
D OFNP
A
Which of the following most accurately defines a collection of rules put out by a
governmental authority at the state level in the US?
A Regulations
B Best Practices
C Applications
D Guidelines
B
What is the Category 6 cable performance designation?
A 100 MHz
B 250 MHz
C 500 MHz
D 600 MHz
A
Which one of the following types of optical fibre cable should be colour coded with an
,Orange outer cable sheath?
A MM with a 100 um core diameter
B Dispersion-shifted SM optical fibre
C Polarization maintain SM optical fibre
D SM optical fibre
D
What is the major advantage in using wall-mounted racks and cabinets instead of
making use of traditional equipment racks?
A Provides the equipment with a much higher level of protection
B Makes it easier to rearrange the equipment
C Provides the best airflow around equipment in the equipment room
D Uses less equipment room space
C
Which topology is based on a linear design where all devices on the network are
connected on a single piece of cable?
A Star
B Ring
, C Bus
D
Which Two organizations have been responsible for the standardized coordination of
telecommunications cabling on a global level?
A Alliance for Telecommunications Industry Solutions (ATIS) and Society for Cable
Telecommunications Engineers (SCTE)
B National Electrical Contractors Association (NECA) and National Fire Protection
Association (NFPA)
C Comite Europeen de Normalisation Electrotechnique (CENELEC) and Electronic
Industries Association (EIA)
D International Organization for Standardization (ISO) and International
Electrotechnical Commission (IEC)
B
Which one of the following is designed to provide protection from injurious chemicals?
A Slash-resistant gloves
B Rubber gloves
C Leather gloves
B
Which one of the following is a building-serving space that contains big pieces of
common active equipment?
A TR