100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Fire Inspector 1 Questions and Answers fully Solved

Beoordeling
-
Verkocht
-
Pagina's
7
Cijfer
A+
Geüpload op
24-09-2024
Geschreven in
2024/2025

Exam of 7 pages for the course Fire Inspector at Fire Inspector (Fire Inspector 1)

Instelling
Fire Inspector
Vak
Fire Inspector









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Fire Inspector
Vak
Fire Inspector

Documentinformatie

Geüpload op
24 september 2024
Aantal pagina's
7
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Fire Inspector 1

During an inspection, you walk inside a building where automobiles are stored. Such
storage indicates the need for? - answerA permit or written approval.

The formula used for determining available water using the mathematical method is
the? - answerHazen-Williams formula.

A looped feed fire hydrant? - answerIs supplied from two or more directions.

Light fixture in a dipping and coating area must be sealed in order to prevent? -
answerVapors from escaping.

Identify THREE NFPA requirements for a building's stock of a spare sprinklers? -
answer• The sprinklers must correspond to the type and rating of the sprinklers in use
• A sprinkler wrench must be stored in the cabinet with the spare sprinklers
• Spare sprinklers must be located on the premises.

A fire load classified as "moderately severe" by the National Institute of Standards and
Technology (NIST) is typically? - answer10 to 15 psf (50 to 75 kg/mz)

When inspecting an HVAC system, check that ducts for? - answerSmoke detectors.

The means of egress must be illuminated at a minimum of _____ foot-candle(s)? -
answerOne.

All of the following are examples of mercantile occupancies EXCEPT? - answerLaw
offices.

Identify the TWO ways by which the hazard contents of a building are classified? -
answer• Character of the contents
• Processes or operations conducted in the building.

The primary difference between Types l & Type ll construction is that Type ll
construction? - answerProvides a lesser degree of fire resistance.

A burning 6 amp motor should be extinguished with a? - answerClass C fire
extinguisher.

C02's main utility as an extinguishing agent is to? - answerSmothering capacity.

, The service- specific item that contains a checklist of areas/systems inspect is? -
answerThe Fire Prevention/ Protection Record.

The reference library provides the authority and guidance for the inspection,
maintenance, and testing all of the following except? - answerPumper apparatus
criteria.

Identify TWO ways educated member of the community can prevent or reduce life and
property loss? - answer• Recognizing and eliminating fire safety deficiencies in their
homes and officer
• Taking appropriate actions during and emergency.

DoD agencies are directed to adopt polices for records management and disposition
by? - answerDoDD 5015.2.2

If you have to participate in legal proceeding, make sure that are dressed in an
appropriate uniform? - answerSpeak in a well- modulated voice, not too loud or too soft.

The MAIN reason to develop an outline before you start to write your document is so
you can later? - answerOrganize your thoughts.

When performing a fire flow test, the hydrant closest to eh location requiring the test
results in known as the? - answerFlow hydrant.

Water distribution systems are made up of primary feeders (mains), secondary feeders,
and? - answerDistributors.

All weather ground access has to be available on _____ side(s) of a building? -
answer2.

According to NFPA 1, Fire Code, the minimum vertical clearance for a fire lane is? -
answer13 feet, 6 inches (4.1m)

Identify THREE important things to check or validate during a visual inspection of a fire
extinguisher? - answerLook for signs of visible physical damage, Ensure the pin and
seal are in place, Check the inspection tag.

When inspecting the distribution main in a sprinkler system, pay careful attention to all
components because the distribution main is the pipe that? - answerProvides the water
supply for the system.

The purpose of a dry pipe valve is to? - answerKeep water out of the sprinkler system
until a fire activates a sprinkler.

Identify TWO ways you may be able to determine whether a decorative material meets
NFPA requirements? - answer• Performing a field flammability test

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
julianah420 Phoenix University
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
657
Lid sinds
2 jaar
Aantal volgers
324
Documenten
34028
Laatst verkocht
1 week geleden
NURSING,TESTBANKS,ASSIGNMENT,AQA AND ALL REVISION MATERIALS

On this page, you find all documents, package deals, and flashcards offered by seller julianah420

4.3

149 beoordelingen

5
101
4
20
3
8
2
5
1
15

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen