How many windings does the auto transformer have? ---------- Correct Answer ----------- 1

To produce x-rays, a cloud of electrons are necessary and the cathode must have a strong
positive charge. ----------- Correct Answer ------------ False

Which of the following occurs first in the sequence of events leading to x-ray production? --------
--- Correct Answer ------------ Voltage becomes kilovoltage.

The rate of flow of electrons passing through the x-ray tube during an exposure is -----------
Correct Answer ------------ tube current.

The operating console contains circuits that are ------------ Correct Answer ------------ low voltage
only

Thermionic emission at the filament determines the ______ across the x-ray tube during an
exposure ------------ Correct Answer ------------ Milliamperage (mA)

The auto transformer has ______winding(s) ------------ Correct Answer ------------ 1

A grid reduces the amount of scatter radiation that reaches the patient ------------- Correct Answer
----------- false

Grids absorb almost all of the scatter radiation and allow all of the transmitted photons to pass
through to the IR. ------------- Correct Answer ----------- false

Adding a grid or increasing grid ratio results in an increase in patient dose. ------------- Correct
Answer ----------- true

Should the thickest part or the thinnest part be placed under cathode? ---------- Correct Answer --
--------- Thickest

The target of the rotating anode is usually coated with a _____ alloy ------------ Correct Answer -
---------- Tungsten

Because of the line focus principal, the effective focal spot size decreases with decreasing _____.
------------ Correct Answer ----------- target angle

What is the most common cause of tube failure ------------ Correct Answer ----------- tungsten
vaporization

,What are the three main parts of the x-ray imaging system? ---------- Correct Answer ----------- x-
ray tube, operating console, high voltage generator

True or false? The x-ray beam generated by the circuit with the lowest voltage ripple has the
highest quantity and quality. ---------- Correct Answer ----------- True

What type of generator units do mammography units operate with? ---------- Correct Answer -----
------ High frequency generators

Are long or short exposure times more likely to cause to failure ---------- Correct Answer ---------
-- Long

Localized, potting, or cracking on the anode can be caused by what? ---------- Correct Answer ---
-------- A single excessive exposure

What causes the anode heal effect? ---------- Correct Answer ----------- Xray absorption within
the anode

True or False? As an x-ray to gets older, the inside may become coded with tungstun, and which
can cause arcing in the tube. ---------- Correct Answer ----------- True

Are the stators on the inside or the outside of the glass envelope? ---------- Correct Answer -------
---- Outside

The ___ is the source of radiation in the xray tube ---------- Correct Answer ----------- focal spot

What does the tube rating show? ---------- Correct Answer ----------- Longest exposure time of
xray tube can be energized without overheating

What creates space charge? ---------- Correct Answer ----------- The heating of the filament which
boils off electrons

What is the target of the rotating and usually coated with? ---------- Correct Answer -----------
Tungsten

What is the most common cause for tube failure? ---------- Correct Answer ----------- tungsten
vaporization

High capacity tube rotors revolve at _____ rpm. ---------- Correct Answer ----------- 10,000

How many filaments does a dual focus tube have? ---------- Correct Answer ----------- 2

Is the filament on the positive or negative side of the tube? ---------- Correct Answer -----------
Negative

What is a filament made of? ---------- Correct Answer ----------- Tungsten

, What are the components of the anode? ---------- Correct Answer ----------- stator and rotor

What are the components of the cathode? ---------- Correct Answer ----------- filament and
focusing cup

With the rotating anode the focal spot becomes what? ---------- Correct Answer ----------- Focal
track

Why does the focusing cup keep the electrons together? ---------- Correct Answer -----------
Repelling them into a group bc negative repels negative

What is the stator made of? ---------- Correct Answer ----------- electromagnets

What happens to the tube if you prep the rotor, but do not expose an x-ray often? ----------
Correct Answer ----------- Damage

Where is the main power switch located? ---------- Correct Answer ----------- primary circuit

Where is the primary side of the high voltage transformer found? ---------- Correct Answer -------
---- primary circuit

Where is the timer circuit found? ---------- Correct Answer ----------- primary circuit

Where is the step down transformer found? ---------- Correct Answer ----------- filament circuit

What is the purpose of a line compensator? ---------- Correct Answer ----------- Measures and
stabilizes voltage

What is the purpose of the rectifier? ---------- Correct Answer ----------- Convert AC to DC

What is the purpose of the filament circuit? ---------- Correct Answer ----------- Boils electrons/
thermionic emission

What is the primary purpose of a step down transformer? ---------- Correct Answer -----------
Coverts high voltage to low voltage

To produce x-rays, does a cathode require positive or negative charge? ---------- Correct Answer
----------- Negative

What is tube current? ---------- Correct Answer ----------- Rate of flow of electrons

AEC ---------- Correct Answer ----------- automatic exposure control

What does AEC control? ---------- Correct Answer ----------- the quantity of radiation reaching
the IR

Document information

Uploaded on
September 23, 2024
Number of pages
21
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$25.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
johnwachi22
4.3
(281)
Sold
1232
Followers
957
Items
4040
Last sold
2 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions