Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 34 pages
Exam (elaborations)

IEC Final Exam Year 1 Questions and Answers 2024

Document preview thumbnail
Preview 4 out of 34 pages

What is the result if the neutral wire becomes open on a multiwire circuit having unequal loads? a. The load of higher resistance would overheat and probably be damaged. b. The load of lesser resistance would overheat and probably be damaged. c. No effect until one load is turned off or opens. d. No effect. a. The load of higher resistance would overheat and probably be damaged. Circuits 7 and 9 share a neutral. This is a multiwire branch circuit. If Ckt. 7 is drawing 13 amps and Ckt. 9 is drawing 16 amps, how much current is flowing in the neutral? a.3 b.13 c.29 d.16 3 Amps The Code reference that specifies the type of disconnecting means (circuit breaker for example) that can be used on a multiwire branch circuit that feeds devices mounted on the same yoke [a stack switch or a duplex receptacle for example] is ___.Note: Select N/A (not applicable) if there is not an NEC® requirement. a.Article 100 b.240.15(B)(1) c.404.8(A) d.N/A b. 240.15(B)(1) Voltmeters are connected in ___ with the load when used to measure voltage across a load in a circuit. Parallel The neutral has been removed from the neutral bar in the circuit shown in Figure 128.407. Lamp 3 is connected in ___ with Lamps 1 and 2. Series (3 wire parallel circuits turn to series when the neutral is disconnected from the neutral bar) What is the minimum number of receptacles required in an unfinished basement? a.2 b.4 c.1 d.0 c. 1 The overall diameter (including insulation) of a 250 kcmil THHN/THWN copper conductor is ___ inches? a..082 b..397 c..765 d..711 e..575 d. 711 NEC Chapter 9 Table 5 pg 701 What part of the NEC® is a reference for calculating conduit fill where all conductors are the same size? a.Article 100 b.Table 310.15(B)(16) c.Annex C d.Table 314.16(A) c. Annex C

Content preview

IEC Final Exam Year 1



IEC Final Exam Year 1 Questions and
Answers 2024
What is the result if the neutral wire becomes open on a multiwire circuit having
unequal loads?
a.
The load of higher resistance would overheat and probably be damaged.
b.
The load of lesser resistance would overheat and probably be damaged.
c.
No effect until one load is turned off or opens.
d.
No effect.
a.
The load of higher resistance would overheat and probably be damaged.




Circuits 7 and 9 share a neutral. This is a multiwire branch circuit. If Ckt. 7 is
drawing 13 amps and Ckt. 9 is drawing 16 amps, how much current is flowing in
the neutral?


a.3
b.13
c.29
d.16

IEC Final Exam Year 1

,IEC Final Exam Year 1


3 Amps




The Code reference that specifies the type of disconnecting means (circuit breaker
for example) that can be used on a multiwire branch circuit that feeds devices
mounted on the same yoke [a stack switch or a duplex receptacle for example] is
___.Note: Select N/A (not applicable) if there is not an NEC® requirement.


a.Article 100
b.240.15(B)(1)
c.404.8(A)
d.N/A
b. 240.15(B)(1)




Voltmeters are connected in ___ with the load when used to measure voltage
across a load in a circuit.
Parallel




The neutral has been removed from the neutral bar in the circuit shown in Figure
128.407. Lamp 3 is connected in ___ with Lamps 1 and 2.
Series
(3 wire parallel circuits turn to series when the neutral is disconnected from the
neutral bar)



IEC Final Exam Year 1

,IEC Final Exam Year 1




What is the minimum number of receptacles required in an unfinished basement?


a.2
b.4
c.1
d.0
c. 1




The overall diameter (including insulation) of a 250 kcmil THHN/THWN copper
conductor is ___ inches?


a..082
b..397
c..765
d..711
e..575
d. 711


NEC Chapter 9 Table 5 pg 701




What part of the NEC® is a reference for calculating conduit fill where all
conductors are the same size?

IEC Final Exam Year 1

, IEC Final Exam Year 1




a.Article 100
b.Table 310.15(B)(16)
c.Annex C
d.Table 314.16(A)
c. Annex C




What is the minimum trade size Schedule 80 PVC required to contain four 8 AWG
THHN/THWN copper conductors?


a.1
b.3/4
c.11/4
d.11/2
e.none of these
b. 3/4


NEC Annex C




Eleven #12, five #10, and six #6 THHN/THWN conductors will be installed in a run
of EMT. The smallest trade size EMT you can use is ___.


a.11/2

IEC Final Exam Year 1

Document information

Uploaded on
September 18, 2024
Number of pages
34
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PossibleA
3.9
(149)
Sold
1063
Followers
651
Items
13881
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions