COSC 325 Houston (plumbing) Questions and Answers Why must horizontal vents be sloped? - ANS-so water cannot accumulate Main Vent (Vent Stack) - ANS-A vertical vent pipe that provides air circulation to/from any part of a drainage system. Branches connect here. How far above the flood level rim of the highest fixture should a branch vent be? - ANS-6" Why are storm water and sanitary waste separated? - ANS-Rain water takes up large volumes and sanitary must go to a treatment plant Purpose of roof drain - ANS-receive rainwater and discharge into leader When are storm drain traps required? - ANS-When roof drain body is within 10' of an opening Max water pressure allowed in buildings - ANS-80psi Purpose of a pressure-reducing valve - ANS-to reduce the pressure of the MAIN system to a predetermined lower pressure in the SUBsystem. When street main fluctuates in pressure, water supply to building must be constant. GPM - ANS-Gallons per minute. Quantity of fluid flow. wsfu - ANS-water supply fixture units. Measure of the estimated water demand of a plumbing fixture Water closet mounting - ANS-floor set and wall hung Max volume of water used for flushing wc - ANS-1.6 gallons per flush flush tank - ANS-a tank located above or integral with the water closet, urinal or similar fixtures for flushing or removing excrements in the fixture Flushometer valve - ANS-is a device, which discharges a predetermined quantity of water into fixtures for flushing purposes and is actuated by direct water pressure diaphragm flushometer valve - ANS-flushometer valve in which a segmented diaphragm within the valve body controls the flushing water by equalizing pressure on both sides of the diaphragm Min clear space in front of WC - ANS-48" Max height for a urinal flush valve - ANS-44" Min knee clearance for lavatory - ANS-29" min knee clearance for drinking fountain - ANS-27" Max volume used for flushing urinals - ANS-1 gal per flush Lavatory mounting types - ANS-wall-hung, pedestal, countertop, self-rimming, under-counter electronic power faucets - ANS-battery powered or plugged into a receptacle clothes washer outlet box - ANS-plastic enclosure that accommodates water supply and waste connections for a clothes washer hard water - ANS-Water that has certain dissolved ions in it - predominately calcium and magnesium ions water softener - ANS-a device containing an ion-exchange resin that is used to treat water by removing ions causing water hardness types of water softeners - ANS-cabinet and two-tank

Content preview

COSC 325 Houston
(plumbing) Questions
and Answers
Why must horizontal vents be sloped? - ANS-so water cannot
accumulate

Main Vent (Vent Stack) - ANS-A vertical vent pipe that provides
air circulation to/from any part of a drainage system. Branches
connect here.

How far above the flood level rim of the highest fixture should a
branch vent be? - ANS-6"

Why are storm water and sanitary waste separated? - ANS-Rain
water takes up large volumes and sanitary must go to a
treatment plant

Purpose of roof drain - ANS-receive rainwater and discharge
into leader

When are storm drain traps required? - ANS-When roof drain
body is within 10' of an opening

Max water pressure allowed in buildings - ANS-80psi

, Purpose of a pressure-reducing valve - ANS-to reduce the
pressure of the MAIN system to a predetermined lower
pressure in the SUBsystem. When street main fluctuates in
pressure, water supply to building must be constant.

GPM - ANS-Gallons per minute. Quantity of fluid flow.

wsfu - ANS-water supply fixture units. Measure of the
estimated water demand of a plumbing fixture

Water closet mounting - ANS-floor set and wall hung

Max volume of water used for flushing wc - ANS-1.6 gallons per
flush

flush tank - ANS-a tank located above or integral with the water
closet, urinal or similar fixtures
for flushing or removing excrements in the fixture

Flushometer valve - ANS-is a device, which discharges a
predetermined quantity of water
into fixtures for flushing purposes and is actuated by direct
water pressure

diaphragm flushometer valve - ANS-flushometer valve in which
a segmented diaphragm within the valve body controls the
flushing water by equalizing pressure on both sides of the
diaphragm

Document information

Uploaded on
September 18, 2024
Number of pages
11
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
JoyceWWales
3.9
(29)
Sold
144
Followers
18
Items
3414
Last sold
3 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions